37. Zinc sulphate tablets and oral solutions having 10 mg and 20 mg of elemental zinc.

The provisions of Chapter IV of the Act and rules thereunder which require them to be covered by a sale licence, subject to the condition that such a product has been manufactured under a valid drug manufacturing licence.]
[SCHEDULE L-I]
(See rules 74, 78 and 150-E)
GOOD LABORATORY PRACTICES AND REQUIREMENTS OF PREMISES AND EQUIPMENTS
General requirements
(a) The laboratory or the organisation of which it is a part must be an entity that is legally authorized to function and can be held legally responsible.
(b) It is the responsibility of the management to ensure that the laboratory carry out its testing, calibration, validation, and all other technical activities in such a way as to meet Good Laboratory Practices (GLP) requirements.
(c) Laboratory management shall have a qualified individual to be known as quality manager or technical manager for carrying out all technical activities and for the implementation of documented quality system and shall report to the top management directly.
(d) The quality manager shall prepare a schedule for technical audit of the laboratory for GLP compliance by an expert or experts appointed by the top-management other than the in-charge of the laboratory and shall ensures the maintenance of documented quality system as per quality, manual.
Premises :-
(a)(i) The laboratories shall be designed, constructed and maintained so as to prevent entry of insects and rodents besides cross contamination;
(ii) interior surface (walls, floor, and ceilings) shall be smooth and free from cracks, and permit easy cleaning and disinfection;
(iii) adequate provision is made not only for space and equipment for carrying out necessary test but also for utilities like water, power and gas;
(iv) air ventilation system shall ensure dust free environment.
(b) The laboratories shall be provided with adequate lighting and ventilation and if necessary, air-conditioning to maintain satisfactory temperature and relative humidity that will not adversely affect the testing and storage of drugs or the accuracy of the functioning of the laboratory equipments or instruments.
(c) The drainage system facilities shall be such as to facilitate proper maintenance and prevent water logging in the laboratory.
(d) Tabletops shall be constructed with acid, alkali and solvent resistant material and shall be smooth and trey from crevices as far as possible.
(e) All bio-medical laboratory waste shall be destroyed as per the provisions of the Bio-Medical Waste (Management and Handling) Rules, 1996.
(f) Adequate space with proper storage conditions in the laboratory shall be provided for keeping reference and working standards and be maintained by the quality control department. Standard Operating Procedure (SOP) for the maintenance of reference standards and evaluation of Working and Secondary standards shall be prepared by the laboratory.
(g) The air circulation is maintained in the area where sterility test is carried out as per Schedule 'M'.
(h) Bio-burden shall be routinely maintained in the controlled and uncontrolled area. (e.g., air locks)
(i) Animal House :--
(i) Animal House shall have the approval of the Committee for the Purpose of Control and Supervision on Experiments on Animals (CPCSEA).
(ii) Designed in such a way that there is an arrangement to quarantine the new animals procured or purchased and have a provision for clean corridor and dirty corridor.
(iii) In case of a diseased animal proper diagnosis shall be done and proper record of treatment shall be maintained.
(iv) Different types of animals shall be housed separately with proper identification.
(v) A Standard Operating Procedure shall be prepared for breeding and care of animals, maintenance, cleaning or sanitation with suitable schedule for cleaning of animal cages, racks, floor and other equipments.
(vi) The animal house shall have proper air-conditioning (temperature and humidity) with proper lighting and be monitored regularly and documented periodically.
Personal :-
(a) Staff in the laboratory shall possess necessary qualification, proper training and shall have adequate, experience for the assigned duties.
(b) A training record of all the personnel shall be maintained.
(c) Head of the laboratory must be of high professional standing with experience in drug analysis and laboratory management who is responsible for :-
(i) ensuring the control and maintenance of documents including the quality system as per the requirements of regulatory authorities which involves all raw data, SOPs, documentation exhibits, protocols, training charts, etc.;
(ii) planning and organising the audit of the quality system and initiation as well as follow up action of the corrective actions, if any;
(iii) investigation of technical complaints;
(iv) taking final responsibilities for recommending any regulatory action in the event of noncompliance of tested samples.
Equipments :-
(a) The laboratory shall be furnished with all types of equipments as may be necessary for carrying out the different activities within the laboratory.
(b) The analytical instruments shall be housed in dust-tree environment and whenever required, conditions of temperature and humidity shall be maintained and periodic checks on temperature and humidity be made and recorded.
(c) The instruments, instrument bench and surrounding areas shall be kept clean and tidy at all times.
(d) Instruments requiring calibration shall be calibrated at regular intervals and records of such calibration or maintenance be maintained and there shall be written instructions in the form of Standard Operating Procedures for the operation, maintenance and calibration of instruments.
(e) Equipment records shall be maintained and such records shall contain the following :-
(i) name of equipment or machine or apparatus;
(ii) manufacturer's name, model number and type of identification;
(iii) serial number;
(iv) date on which equipment was received in laboratory;
(v) current location;
(vi) condition when received (e.g., new, used, re-conditioned);
(vii) copy of the manufacturer's operating instructions;
(viii) frequency of calibration;
(ix) frequency of maintenance;
(x) log Book (day to day entry including status of the equipment);
(xi) staff responsible for monitoring the calibration and maintenance status of the equipment;
(xii) calibrating records;.
(xiii) list of authorized users or operators, if any;
(xiv) history of any damage, malfunction, modification or upgradation, repair and calibration;
(xv) list of spares and accessories, if any.
(f) A progress register for non-functional equipments and action for procurement of spares and accessories, monitoring thereof, shall be maintained.
(g) A Standard Operating Procedure for preventive maintenance of machine or equipment or apparatus shall be prepared by the laboratory.
(h) Other equipments such as burettes, pipettes, volumetric flasks, weight boxes, thermometers, etc., shall be thoroughly checked for accuracy of calibration before acceptance for use.
(i) Maintenance procedure in the form of Standard Operating Procedures must be prepared and regular servicing must be performed by the maintenance engineer or specialist.
(j) Equipments, instruments giving anomalous results or defective must be labeled as "out-of-order" till they are repaired and after instrument is repaired it should be calibrated before use.
(k) The maintenance of equipments for services like electricity, gas, water, steam, and compressed gas shall be handled by competent person.
(l) Autoclaves must meet the requirements described for operations, safety and validation procedures, and the validation carried out by the laboratory shall be recorded.
(m) Fume Cupboards.-Work involving the evolution of harmful and obnoxious vapours shall be carried out in a fume cupboard. The exhaust system of the fume cupboard shall be checked frequently to ensure that it is in order. There should be a water drainage system inside the fume cupboard and shall be checked frequently to ensure that there is no water logging and it is in order.
Chemicals and Reagents :-
(a) The storage and handling of chemicals and reagents shall be done in a manner considering the physicochemical properties of these substances and the hazards involved in their use.
(b) All reagents and solutions in the laboratory shall be properly identified with a label.
(c) A standardisation register shall be maintained by the laboratory along with its raw data and Standard Operating Procedure for preparation and standardisation on stock solutions, standard solutions, volumetric solutions must be prepared for the guidance of staff.
(d) Containers of stock solutions and of standard solutions shall bear the following details :
(i) name of analytical chemist who prepared the solution;
(ii) date of preparation;
(iii) Each volumetric solution shall have "use before date" depending upon the stability of the solution; and
(iv) standardisation records.
(e) The transfer of hazardous chemicals and regents from one container to another container shall be carried out with suitable equipment by taking the care of safety and no make-shift or hazardous methods must he resorted to.
Good house keeping and safety :-
(a) General and specific written down instructions for safety shall be circulated to each staff member and the instructions be revised periodically as appropriate (e.g., poster displays, audio-visual material and by seminars/conferences).
(b) Standard Operating Procedure for safety, house-keeping and loss prevention shall be prepared in accordance with the various rules, and regulations of the Government of India and include the following requirements, namely :-
(i) safety data sheets must be made available to staff before testing is carried out;
(ii) drinking, eating and smoking shall not be permitted in the laboratories; food for human consumption shall not be kept in working or storage areas; food meant for test animals shall be handled by the workers under the guidance of a veterinary doctor or qualified person. In the animal house, the facilities for collection and disposal of animal waste or safe sanitary storage of waste before removal from testing be provided;
(iii) staff must wear laboratory coats or other protective clothing including gloves and face masks and eye protection wherever required;
(iv) the laboratories shall have adequate first aid kit and fire fighting equipments located at the right places and the staff must be familiar and trained with the use of fire fighting equipment including fire extinguishers, fire blankets and gas masks,
(v) operators carrying out sterility tests shall wear sterilised garments including headgear, face masks and shoes;
(vi) the staff must be educated in the first aid techniques, emergency care and use of antidotes; and
(vii) safety rules in handling cylinders of compressed gases must be observed and staff must be familiar with relevant colour identification codes;
(c) Protective precautions to be taken in laboratories :
(i) water showers shall be installed at appropriate places in the laboratory;
(ii) rubber suction bulbs must be used on manual pipettes and siphons;
(iii) warnings, precautions, and written instructions must be given for work with violent, uncontrollable or dangerous reactions (e.g., mixing water and acids, biological such as infectious agents, etc.);
(iv) appropriate facilities for the collection, storage, and disposal of wastes shall be made available.
(v) staff must be aware of methods for safe disposal of corrosive or dangerous products by neutralisation or deactivation and of the need for complete disposal of mercury and its salts.
(vi) staff must also be aware about the safety precautions to be adopted while handling potassium cyanide and cyanogen bromide.
(vii) a Standard Operating Procedure for handling, collection, disposal of chemical and biological wastes be prepared.
Maintenance, calibration, and validation of equipments :-
(a) All equipments, instruments and other devices used in the laboratory shall use appropriate methods and procedures for all tests or calibrations and they shall be regularly calibrated and validated. The frequency of calibration may differ from instrument to instrument.
(b) The original equipment manufacturer's recommendations along with the experience of the laboratory staff and the use of equipment per day may also be considered while fixing the frequency of calibration.
(c) For most of the equipments and instruments, Standard Operating Procedures for calibration and calibration schedule be prepared by the laboratory and a logbook shall also be prepared by each laboratory for proper documentation of calibration results.
Reference materials :-
(a) Reference materials are necessary for the testing and, or calibration, validation or verification of a sample or of equipment, instruments or other devices and all such materials shall be traceable to agency authorized by Government of India or any other International body.
(b) The laboratory shall prepare working standard by comparing with the reference standard and shall be routinely checked for their purity by selecting parameters such as identity, loss on drying or on water, impurity and assay, etc.
(c) Whenever, any new reference material is received by the laboratory, a code number shall be assigned and this code number shall be quoted on the laboratory note book and analytical work sheet. The working standard shall also be provided with identification code.
(d) A register pertaining to reference and working materials must be maintained by the laboratory. The following details may be mentioned in the register :-
(i) source of supply;
(ii) code number of the reference material;
(iii) date of receipt;
(iv) batch number or identification number of the supplying agency;
(v) details like assay value, water content or any other information provided;
(vi) storage condition of the material; and
(vii) date of expiry, if any and date of manufacturing if possible.
(e) All working standards shall be checked at appropriate intervals or before use to ensure that it has not deteriorated or decomposed during storage. These observations be recorded in a register. All the reference and working standards shall be stored at appropriate storage condition; those requiring storage between 2-8°C shall be stored in a refrigerator. Wherever recommended the material may not be allowed to be frozen.
Microbiological Cultures :-
(a) Standard Operating Procedure for maintenance of microbial culture and sub-culture must be prepared by the laboratories.
(b) If the cultures have become non-viable or mutant, proper procedure shall be followed to destroy these cultures by autoclaving under an authorized personnel for biological testing. Preferably not more than five passages may be prepared.
(c) All activities be carried out in a aseptic area by authorized person.
(d) The laboratories shall perform standard biochemical tests on the sub-culture as given in literature to ensure their viability.
Quality system :-
(a) the measurements and calibrations shall fully conform to the compendial requirements and the methods demonstrably based on validation protocols are followed;
(b) it shall be effective in providing necessary assurance that the activities or processes or techniques or practices comply with planned arrangements;
(c) it helps in early detection and correction of non-conformities;
(d) remedial action on the observations by internal and external audits are taken appropriately; and
(e) It shall have a documented quality policy for the organisation.
Internal quality system audits :-
(a) Internal audits are done to assure the integrity of the analysis and such audits shall be conducted periodically with a predetermined schedule and procedure with appropriate checklist, to verify that the operations continue to comply with the requirements of quality system and requirements of regulatory authorities. Internal quality audits shall be carried out by trained and qualified personnel who are independent of the activity to be audited.
(b) The periodicity of quality audit shall be fixed by the Head of the laboratory so that each activity is audited at least once in a year.
(c) Head of the laboratory will be responsible for initiation of the corrective action arising from audits and verification of corrective action.
(d) Whenever any non-compliance or any diversion is noticed by the team in implementing quality policy or quality system, protocols, the same will be attended by the Quality Manager. The problem will be analyzed and necessary actions will be taken with proper documentation.
(e) The Quality Manager shall maintain all the records of the analysis being conducted which includes test system, the type of analysis, date on which analysis is done, etc., and quality Manager shall also maintain copies of all protocols pertaining to different activities being checked by the audit team.
Management review.
(i) report or input of internal audits;
(ii) matter arising from previous reviews;
(iii) report of external audits, if any;
(iv) surveillance report, if any;
(v) result of proficiency testing;
(vi) complaints or feedback received from users of laboratory services;
(vii) details of in-house quality control checks;
(viii) need of amendment of the quality system and documentation;
(ix) induction training of new staff; and
(x) any other requirements of the laboratory.
Standard operating procedures
(a) Standard Operating Procedures are written procedures for different activities being conducted in a laboratory and shall include the following characteristics :-
(i) they shall be written in a chronological order listing different steps leading to an analysis of drugs or calibration of an instrument;
(ii) testing laboratories shall have Standard Operative Procedure manuals and have its periodic review;
(iii) it shall be user friendly documents and shall include designation of the person responsible for intended activity.
(b) Standard Operating Procedures in addition to those recommended under various activities shall also be prepared to the minimum in respect of the following :-
(i) sample handling and accountability;
(ii) receipt identification, storage, mixing and method sampling of the test and control articles;
(iii) record keeping, reporting, storage and retrieval of data;
(iv) coding of different studies, handling of data including use of computerised data system;
(v) operation of technical audit personnel in performing and reporting audits, inspections and final report reviews;
(vi) routine inspection of cleaning, maintenance, testing, calibration and standardisation of instruments;
(vii) action to be taken in respect of equipment failure;
(viii) analytical data methods;
(ix) the raw data;
(x) data handling and storage retrieval;
(xi) health and safety protection;
(xii) animal room preparations;
(xiii) animal care;
(xiv) storage and maintenance of microbial cultures;
(xv) maintenance of sterility room (i.e., constant maintenance and monitoring of Aseptic condition of sterility room);
(xvi) use and storage of reference standards;
(xvii) procurement of stores and equipment;
(xviii) monitoring of testing of samples;
(xix) method of retention of unexpended samples, their location, maintenance and;
(x) document control;
(xxi) redressal of technical complaints;
(xxii) housing-keeping;
(xxiii) corrective and preventive action;
(xxiv) working procedure (test methods);
(xxv) calibration Manual; and
(xxvi) training manual.
Protocols and specifications archive :-
(a) Every laboratory shall have a specification archive and current versions of all necessary specifications shall be kept as per the requirements of the Act and the rules made thereunder and the National Pharmacopoeia (Indian Pharmacopoeia).
(b) All updates and corrections must be noted in the master volumes of Pharmacopoeias to prevent the use of obsolete sections; supplement and addendum shall also be made available in the laboratory.
(c) The specification archive shall contain the following :-
(i) list of all the pharmacopoeias;
(ii) a file on patent and proprietary medicines (non-pharmacopoeial) test methods to specifications prepared and validated by the manufacturer or by the laboratory itself. The test methods shall be submitted to the concerned Drug Control Authority. The validated test methods developed by the manufacturer or the laboratory shall stand to the requirements of compendial parameters in regard to its precision, accuracy, reproducibility, specificity, linearity, and ruggedness, etc.
Raw data :-
(a) Raw data refers to the laboratory work sheet, note books or analysis sheet, records, memorandum, notes or extract copies thereof that may be the results of general observations and other activities and such raw data shall include hand written notes, photographs, software, drawings, computer printouts, spectral charts, dictated observations or recorded data from automated equipments. The raw data also includes record on receipt of animals, result of environmental monitoring, calibration, records of equipments, integrator output from analytical equipment, including work-sheet used to read a note, information from Light Emitting Diode (LED) display of any equipment.
(b) A single line shall strike through the data being changed; the correct information shall be recorded along with the old data and the reason of change. The analyst making the change shall be identified by his signature with date. In case of automated data collection system, the person responsible shall be identified at the time of data output The original entry must be saved and the system shall have audit trail for all the data.
(c) Data integrity and security shall be maintained and the data shall not be accessible to any unauthorized person.
Storage and archival :-
(a) The residual sample shall be retained in proper storage condition for a period of one year after the final report.
(b) The laboratory must establish and maintain procedures for the identification collection, indexing, retrieval, storage, maintenance and disposal of all quality documents.
(c) All the raw data, documentation, Standard Operative Procedres,.protocols and final reports are to be retained and there shall be archives for orderly storage and expeditious retrieval of all raw data, documentation, protocols, interim and final report. The archive shall provide a suitable environment that will prevent modification, damage, or deterioration and/or loss.
(d) The condition under which the original documents are stored must ensure their security and confidentiality.
(e) Paper documents shall not be kept for long periods under high humidity and raw data in the form of tape and discs are to be preserved with care.
(f) In case of storage of only optical disc, the life of disc shall be longer than the storage time.
(g) Raw data on thermal paper might fade away with time; therefore, a photocopy of the thermal paper shall also be retained in the archive.
(h) Time for which records are retained shall be prescribed in the documents.
[SCHEDULE M]
(See rules 71, 74, 76 and 78)
GOOD MANUFACTURING PRACTICES AND REQUIREMENTS OF PREMISES, PLANT AND EQUIPMENT FOR PHARMACEUTICAL PRODUCTS
Note.
PART I
PART I
GOOD MANUFACTURING PRACTICES FOR PREMISES AND MATERIALS
General requirements
(i) compatible with other drug manufacturing operations that may be carried out in the same or adjacent area/section;
(ii) adequately provided with working space to allow orderly and logical placement of equipment, materials and movement of personnel so as to--
(a) avoid the risk of mix-up between different categories of drugs or with raw materials, intermediates and in-process material;
(b) avoid the possibilities of contamination and cross-contamination by providing suitable mechanism;
(iii) designed/constructed/maintained to prevent entry of insects, pests, birds, vermins, and rodents. Interior surface (walls, floors, and ceilings) shall be smooth and free from cracks and permit easy cleaning, painting and disinfection;
(iv) air-conditioned, where prescribed for the operations and dosage forms under production. The production and dispensing areas shall be well lighted, effectively ventilated, with air control facilities and may have proper air handling units (wherever applicable) to maintain conditions including temperature and, wherever necessary, humidity, as defined for the relevant product. These conditions shall be appropriate to the category of drugs and nature of the operation. These shall also be suitable to the comforts of the personnel working with protective clothing, products handled, operations undertaken within them in relation to the external environment. These areas shall be regularly monitored for compliance with required specifications;
(v) provided with drainage system, as specified for the various categories of products, which shall be of adequate size and so designed as to prevent back-flow and/or to prevent insects and rodents entering the premises. Open channels shall be avoided in manufacturing areas and, where provided, these shall be shallow to facilitate cleaning and disinfection; and
(vi) The walls and floors of the areas where manufacture of drugs is carried out shall be free from cracks and open joints to avoid accumulation of dust. These shall be smooth, washable, covered and shall permit easy and effective cleaning and disinfection. The interior surfaces shall not shed particles. A periodical record of cleaning and painting of the premises shall be maintained.
(ii) All bio-medical waste shall be destroyed as per the provisions of the Bio-Medical Waste (Management and Handling) Rules, 1996.
(iii) Additional precautions shall be taken for the storage and disposal of rejected drugs. Records shall be maintained for all disposal of waste.
(iv) Provisions shall be made for the proper and safe storage of waste materials awaiting disposal. Hazardous, toxic substances and flammable materials shall be stored in suitably designed and segregated, enclosed areas in conformity with Central and State Legislations.
Warehousing Area
Production area
Ancillary areas
Quality control area
Personnel
Health, clothing and sanitation of workers
Manufacturing operations and controls
Sanitation in the manufacturing premises
(a) specific areas to be cleaned and cleaning intervals;
(b) cleaning procedure to be followed, including equipment and materials to be used for cleaning; and
(c) personnel assigned to and responsible for the cleaning operation.
Raw materials
(a) designated name of the product and the internal code reference, where applicable, and analytical reference number;
(b) manufacturer's name, address and batch number;
(c) the status of the contents (e.g. quarantine, under test, released, approved, rejected); and
(d) the manufacturing date, expiry date and re-test date.
Equipment
Documentation and records
Labels and other printed materials
Quality assurance-
(a) the pharmaceutical products are designed and developed in a way that takes account of the requirements of Good Manufacturing Practices (hereinafter'referred to as GMP) and other associated codes such as those of Good Laboratory Practices (hereinafter referred to as GLP) and Good Clinical Practices (hereinafter referred to as GCP);
(b) adequate arrangements are made for manufacture, supply and use of the correct starting and packaging materials;
(c) adequate controls on starting materials, intermediate products and bulk products and other in-process controls, calibrations and validations are carried out;
(d) the finished product is correctly processed and checked in accordance with established procedures; and
(e) the pharmaceutical products are not released for sale or supplied before authorized persons have certified that each production batch has been produced and controlled in accordance with the requirements of the label claim and any other provisions relevant to production, control and release of pharmaceutical products.
Self-inspection and quality audit
(a) Personnel.
(b) Premises including personnel facilities.
(c) Maintenance of buildings and equipment.
(d) Storage of starting materials and finished products.
(e) Equipment.
(f) Production and in-process controls.
(g) Quality control.
(h) Documentation.
(i) Sanitation and hygiene.
(j) Validation and revalidation programmes.
(k) Calibration of instruments or measurement systems.
(l) Recall procedures.
(m) Complaints management.
(n) Labels control.
(o) Results of previous self-inspections and any corrective steps taken.
Quality control system
Specifications
(a) the designated name and internal code reference;
(b) reference, if any, to a pharmacopoeia] monograph;
(c) qualitative and quantitative requirements with acceptance limits;
(d) name and address of manufacturer or supplier and original manufacturer of the material;
(e) specimen of printed material;
(f) directions for sampling and testing or reference to procedures;
(g) storage conditions; and
(h) maximum period of storage before re-testing.
(a) the designated name of the product and the code reference;
(b) the formula or a reference to the formula and the pharmacopoeia) reference;
(c) directions for sampling and testing or a reference to procedures;
(d) a description of the dosage form and package details;
(e) the qualitative and quantitative requirements, with the acceptance limits for release;
(f) the storage conditions and precautions, where applicable, and
(g) the shelf-life.
Master formula records
(a) the name of the product together with product reference code relating to its specifications;
(b) the patent or proprietary name of the product alongwith the generic name, a description of the dosage form, strength, composition of the product and batch size;
(c) name, quantity and reference number of all the starting materials to be used. Mention shall be made of any substance that may "disappear" in the course of processing;
(d) a statement of the expected final yield with the acceptable limits, and of relevant intermediate yields, where applicable;
(e) a statement of the processing location and the principal equipment to be used;
(f) the methods, or reference to the methods, to be used for preparing the critical equipment including cleaning, assembling, calibrating, sterilising;
(g) detailed stepwise processing instructions and the time taken for each step;
(h) the instructions for in-process controls with their limits;
(i) the requirements for storage conditions of the products, including the container, labelling and special storage conditions where applicable;
(j) any special precautions to be observed; and
(k) packing details and specimen labels.
Packaging records
(a) name of the product;
(b) description of the dosage form, strength and composition;
(c) the pack size expressed in terms of the number or doses, weight or volume of the product in the final container;
(d) complete list of all the packaging materials required for a standard batch size, including quantities, sizes and types, with the code or reference number relating to the specifications of each packaging material;
(e) reproduction of the relevant printed packaging materials and specimens indicating where batch number and expiry date of the product have been applied;
(f) special precautions to be observed, including a careful examination of the area and equipment in order to ascertain the line clearance before the operations begin;
(g) description of the packaging operation, including any significant subsidiary operations and equipment to be used;
(h) details of in-process controls with instructions for sampling and acceptance; and
(i) upon completion of the packing and labelling operation a reconciliation shall be made between number of labelling and packaging units issued, number of units labelled, packed and excess returned or destroyed. Any significant or unusual discrepancy in the numbers shall be carefully investigated before releasing the final batch.
Batch packaging records
Batch processing records
(a) the name of the product,
(b) the number of the batch being manufactured,
(c) dates and time of commencement of significant intermediate stages and of completion of production,
(d) initials of the operator of different significant steps of production and where appropriate, of the person who checked each of these operations,
(e) the batch number and/or analytical control number as well as the quantities of each starting material actually weighed,
(f) any relevant processing operation or event and major equipment used,
(g) a record of the in-process controls and the initials of the person(s) carrying them out, and the results obtained,
(h) the amount of product obtained after different and critical stages of manufacture (yield),
(i) comments or explanations for significant deviations from the expected yield limits shall be given,
(j) notes on special problems including details, with signed authorisation, for any deviation from the master formula,
(k) addition of any recovered or reprocessed material with reference to recovery or reprocessing stages.
Standard operating procedures (SOPs) and records, regarding
(a) the name of the material on the delivery note and the number of the containers;
(b) the date of receipt;
(c) the manufacturer's and/or supplier's name;
(d) the manufacturer's batch or reference number;
(e) the total quantity, and number of containers, quantity in each container received;
(f) the control reference number assigned after receipt; and
(g) any other relevant comment or information.
(a) the method of sampling and the sampling plan,
(b) the equipment to be used,
(c) any precautions to be observed to avoid contamination of the material or any deterioration in its quality,
(d) the quantity of samples to be taken,
(e) instructions for any required sub-division or pooling of the samples,
(f) the type of sample container to be used, and
(g) any specific precautions to be observed, especially in regard to sampling of sterile or hazardous material.
(a) name of the material or product and the dosage form,
(b) batch number and, where appropriate, the manufacturer and/or supplier,
(c) references to the relevant specifications and testing procedures,
(d) test results, including observations and calculations, and reference to any specifications (limits),
(e) dates of testing,
(f) initials of the persons who performed the testing,
(g) initials of the persons who verified the testing and the detailed calculations,
(h) a statement of release or rejection, and
(i) signature and date of the designated responsible person.
(a) equipment assembly and validation;
(b) analytical apparatus and calibration;
(c) maintenance, cleaning and sanitation;
(d) personnel matters including qualification, training, clothing, hygiene;
(e) environmental monitoring;
(f) pest control;
(g) complaints;
(h) recalls made; and
(i) returns received.
Reference samples
Reprocessing and recoveries
Distribution records
Validation and process validation
Product recalls-
Complaints and adverse reactions
Site master file
(a) brief information of the firm;
(b) pharmaceutical manufacturing activities as permitted by the licensing authority;
(c) other manufacturing activities, if any, carried out on the premises;
(d) type of products licensed for manufacture with flow charts mentioning procedures and process flow;
(e) number of employees engaged in the production, quality control, storage and distribution;
(f) use of outside scientific, analytical or other technical assistance in relation to manufacture and analysis;
(g) short description of the Quality Management system of the firm; and
(h) product details registered with foreign countries.
(a) organisational chart showing the arrangement for quality assurance including production and quality control;
(b) qualification, experience and responsibilities of key personnel;
(c) outline for arrangements for basic and in-service training and how the records are maintained;
(d) health requirements for personnel engaged in production; and
(e) personal hygiene requirements, including clothing.
(a) simple plan or description of manufacturing areas drawn to scale;
(b) nature of construction and fixtures/fittings;
(c) brief description of ventilation systems. More details should be given for critical areas with potential risk of airborne contamination (schematic drawing of systems). Classification of the rooms used for the manufacture of sterile products should be mentioned;
(d) special areas for the handling of the highly toxic, hazardous and sensitising materials;
(e) brief description of water systems (schematic drawings of systems), including sanitation; and
(f) description of planned preventive maintenance programmes for premises and of the recording system.
(a) brief description of major equipment used in production and quality control laboratories (a list of equipment required);
(b) description of planned preventive maintenance programmes for equipment and of the recording system; and
(c) qualification and calibration including the recording systems and arrangements for computerised systems validation.
(a) availability of written specifications and procedures for cleaning manufacturing areas and equipment.
(a) arrangements for the preparation, revision and distribution of;
(b) necessary documentation for the manufacture; and
(c) any other documentation related to product quality that is not mentioned elsewhere (e.g., microbiological controls about air and water).
(a) brief description of production operations using, wherever possible, flow sheets and charts specifying important parameters;
(b) arrangements for the handling of starting materials, packaging materials, bulk and finished products including sampling, quarantine, release and storage;
(c) arrangements for the handling of rejected materials and products; and
(d) brief description of general policy for process validation.
(a) description of the quality control system and of the activities of the quality control department. Procedures for the release of the finished products.
(a) description of the way in which compliance of Good Manufacturing Practices by the loan licensee shall be assessed.
(a) arrangements and recording system for distribution; and
(b) arrangements for the handling of complaints and product recalls.
(a) short description of the self-inspection system indicating whether an outside, independent and experienced external expert was involved in evaluating the manufacturer's compliance with Good Manufacturing Practices in all aspects of production.
(a) products exported to different countries; and
(b) complaints and product recall, if any.
PART I-A
PART I-A
SPECIFIC REQUIREMENTS FOR MANUFACTURE OF STERILE PRODUCTS, PARENTERAL PREPARATIONS (SMALL VOLUME INJECTABLES AND LARGE VOLUME PARENTERALS) AND STERILE OPHTHALMIC PREPARATIONS
Note.
General
Buildings and civil works
In aseptic areas :-
(a) walls, floors and ceiling should be impervious, non-shedding, non-flaking and non-cracking. Flooring should be unbroken and provided with a cove both at the junction between the wall and the floor as well as the wall and the ceiling;
(b) walls shall be flat, and ledges and recesses shall be avoided. Wherever other surfaces join the wall (e.g., sterilisers, electric sockets, gas points, etc.) these shall flush the walls. Walls shall be provided with a cove at the joint between the ceiling and floor;
(c) ceiling shall be solid and joints shall be sealed. Light fittings and air-grills shall be flush with the walls and not hanging from the ceiling, so as to prevent contamination;
(d) there shall be no sinks and drains in Grade A and Grade B areas;
(e) doors shall be made of non-shedding materials. These may be made preferably of Aluminium or Steel material. Wooden doors shall not be used. Doors shall open towards the higher-pressure area so that they close automatically due to air pressure;
(f) windows shall be made of similar material as the doors, preferably with double panel and shall be flush with the walls. If fire escapes are to be provided, these shall be suitably fastened to the walls without any gaps; and
(g) the furniture used shall be smooth, washable and made of stainless steel or any other appropriate material other than wood.
Air handling system (central air-conditioning)
[TABLE I]
[TABLE I]
THE AIR BORNE PARTICULATE CLASSIFICATION FOR MANUFACTURE OF STERILE PRODUCTS
Grade Maximum number of permitted particles per cubic metre equal to or above At rest (b) In operation (a) 0.5µm 5µm 0.5µm 5µm A 3500 0 3500 0 B(a) 3500 0 3,50,000 2000 C(a) 3,50,000 2000 35,00,000 20,000 D(a) 35,00,000 20,000 Not defined (c) Not defined (c)
Grade
Grade
Maximum number of permitted particles per cubic metre equal to or above
Maximum number of permitted particles per cubic metre equal to or above
At rest (b)
In operation (a)
0.5µm
5µm
0.5µm
5µm
A
3500
0
3500
0
B(a)
3500
0
3,50,000
2000
C(a)
3,50,000
2000
35,00,000
20,000
D(a)
35,00,000
20,000
Not defined (c)
Not defined (c)
Notes.
(b) The requirement and limit for the area shall depend on the nature of the operation carried out.
(c) Types of operations to be carried out in the various grades are given in Table II and Table III as under :
TABLE II
TABLE II
TYPES OF OPERATIONS TO BE CARRIED OUT IN THE VARIOUS GRADES FOR ASEPTIC PREPARATIONS
Grade Types of operations for aseptic preparations. A Aseptic preparation and filling. B Background room conditions for activities requiring Grade A. C Preparation of solution to be filtered. D Handling of components after washing.
Grade
Grade
Types of operations for aseptic preparations.
Types of operations for aseptic preparations.
A
B
C
D
TABLE III
TABLE III
TYPES OF OPERATIONS TO BE CARRIED OUT IN THE VARIOUS GRADES FOR TERMINALLY STERILIZED PRODUCTS
Grade Types of operations for terminally sterilized products. A Filling of products, which are usually at risk. C Placement of filling and sealing machines, preparation of solutions, when [unusually at risk]. Filling of product when unusually at risk. D Moulding , blowing (pre-forming) operations of plastic containers. Preparations of solutions and components for subsequent filling.
Grade
Grade
Types of operations for terminally sterilized products.
Types of operations for terminally sterilized products.
A
C
D
Environmental monitoring
(a) Particulate monitoring in air - 6 Monthly (b) HEPA filter integrity testing
(smoke testing) - Yearly (c) Air change rates - 6 Monthly (d) Air pressure differentials - Daily (e) Temperature and humidity - Daily (f) Microbiological monitoring by settle plates and/or - Daily, and at decreased swabs in aseptic areas frequency in other areas
-
-
-
-
-
-
Note.
TABLE
TABLE
RECOMMENDED LIMITS FOR MICROBIOLOGICAL MONITORING OF CLEAN AREAS "IN-OPERATION"
Grade Air sample Cfu/m 3 Settle plates (dia. 90 mm.) Cfu/2 hrs. Contact plates (dia. 55mm) Cfu per plate Glove points (five fingers) Cfu per glove A <1 <1 <1 <1 B 10 5 5 5 C 100 50 25 - D 500 100 50 -
Grade
Grade
Air sample Cfu/m 3
Air sample Cfu/m 3
Settle plates (dia. 90 mm.) Cfu/2 hrs.
Settle plates (dia. 90 mm.) Cfu/2 hrs.
Contact plates (dia. 55mm) Cfu per plate
Contact plates (dia. 55mm) Cfu per plate
Glove points (five fingers) Cfu per glove
Glove points (five fingers) Cfu per glove
A
<1
<1
<1
<1
B
10
5
5
5
C
100
50
25
-
D
500
100
50
-
Notes.
(b) Individual settle plates may be exposed for not less than two hours in Grade B, C and D areas and for not less than thirty minutes in Grade A area.
Garments
Sanitation
Equipment
Water and steam systems
Manufacturing process
Form-fill-seal technology or blowfill-seal technology
Note.
(ii) These shall comply with the limits as recommended in Table at item 4.2.
(i) Solutions for Large Volume Parenterals shall be filtered through a non-fibre releasing, sterilizing grade cartridge/membrane filter of nominal pore size of 0.22 It for aseptic filling whereas 0.45 µ porosity shall be used for terminally sterilized products.
(ii) A second filtration using another 0.22 µ sterilizing grade cartridge/membrane filter shall be performed immediately prior to filling. Process specifications shall indicate the maximum time during which a filtration system may be used with a view to precluding microbial build-up to levels that may affect the microbiological quality of the Large Volume Parenterals.
(iii) The integrity of the sterilized filter shall be verified and confirmed immediately after use by an appropriate method such as Bubble Point, Diffusive Flow or Pressure Hold Test.
Product containers and closures
(1) Serial number of the Batch Manufacturing Record.
(2) Name of the product.
(3) Reference to Master Formu,,i Record.
(4) Batch/Lot number.
(5) Batch/Lot size.
(6) Date of commencement of manufacture and date of completion of manufacture.
(7) Date of manufacture and assigned date of expiry.
(8) Date of each step in manufacturing.
(9) Names of all ingredients with the grade given by the quality control department.
(10) Quantity of all ingredients.
(11) Control reference numbers for all ingredients.
(12) Time and duration of blending, mixing, etc., whenever applicable.
(13) pH of solution whenever applicable.
(14) Filter integrity testing records.
(15) Temperature and humidity records whenever applicable.
(16) Records of plate-counts whenever applicable.
(17) Results of pyrogen and/or bacterial endotoxin and toxicity.
(18) Records of weight or volume of drug filled in containers.
(19) Bulk sterility in case of aseptically filled products.
(20) Leak test records.
(21) Inspection records.
(22) Sterilization records including autoclave, leakage test records, load details, date, duration, temperature, pressure, etc.
(23) Container washing records.
(24) Total number of containers filled.
(25) Total number of containers rejected at each stage.
(26) Theoretical yield, permissible yield, actual yield and variation thereof.
(27) Clarification for variation in yield beyond permissible yield.
(28) Reference numbers of relevant analytical reports.
(29) Details of reprocessing, if any.
(30) Name of all operations carrying out different activities.
(31) Environmental monitoring records.
(32) Specimens of printed packaging material.
(33) Records of destruction of rejected containers and printed packaging materials.
(34) Signature of the competent technical staff responsible for manufacture and testing.
Notes.
PART I-B
PART I-B
SPECIFIC REQUIREMENTS FOR MANUFACTURE OF ORAL SOLID DOSAGE FORMS (TABLETS AND CAPSULES)
Note.
General
Sifting, mixing and granulation
Compression (Tablets)
Coating (Tablets)
Filling of hard gelatin capsule
Printing (Tablets and capsules)
Packaging (Strip and blister)
PART I-C
PART I-C
SPECIFIC REQUIREMENTS FOR MANUFACTURE OF ORAL LIQUIDS (SYRUPS, ELIXIRS, EMULSIONS AND SUSPENSIONS)
Note.
Building and equipment
Purred water
Manufacturing
PART I-D
PART I-D
SPECIFIC REQUIREMENTS FOR MANUFACTURE OF TOPICAL PRODUCTS i.e., EXTERNAL PREPARATIONS (CREAMS, OINTMENTS, PASTES, EMULSIONS, LOTIONS, SOLUTIONS, DUSTING POWDERS AND IDENTICAL PRODUCTS)
Note.
PART I-E
PART I-E
SPECIFIC REQUIREMENTS FOR MANUFACTURE OF METERED-DOSE-INHALERS (MDI)
Note.
General
Building and civil works
Environmental conditions
Garments
Sanitation
Equipment
Manufacture
Documentation
(1) Temperature and humidity in the manufacturing area.
(2) Periodic filled weights of the formulation.
(3) Records of rejections during online check weighing.
(4) Records of rejections during spray testing.
PART I-F
PART I-F
SPECIFIC REQUIREMENTS OF PREMISES, PLANT AND MATERIALS FOR MANUFACTURE OF ACTIVE PHARMACEUTICAL INGREDIENTS (BULK DRUGS)
Note.
Building and civil works
Sterile products
Utilities/services
Equipment design, size and location
(a) the suitability of the cleaning agent to remove residues of raw materials, intermediates, precursors, degradation products and isomers, as appropriate;
(b) whether the cleaning agent leaves a residue itself;
(c) compatibility with equipment construction materials like centrifuge/filtration, dryer, fluid bed dryer, rotocone proton dryer, vacuum dryer, frit mill, multi-mill/jet mills/sewetters cut sizing;
(d) test for absence of intermediate or active pharmaceutical ingredient in the final rinse.
(a) assignment of responsibility for cleaning and maintaining equipment;
(b) maintenance and cleaning programme schedules, including where appropriate, sanitizing schedules;
(c) a complete description of the methods and materials used to clean and maintain equipment, including instructions for dis-assembling and re-assembling each article of equipment to ensure proper cleaning and maintenance;
(d) removal or obliteration of previous batch identification;
(e) protection of clean equipment from contamination prior to use;
(f) inspection of equipment for cleanliness immediately before use;
(g) establishing the maximum time that may elapse between completion of processing and equipment cleaning as well as between cleaning and equipment reuse.
IN-PROCESS CONTROLS
(a) reaction time or reaction completion;
(b) reaction mass appearance, clarity, completeness or pH solutions;
(c) reaction temperature;
(d) concentration of a reactant;
(e) assay or purity of the product;
(f) process completion check by TLC/any other means.
(a) appearance and colour;
(b) uniformity of the blend;
(c) temperature of a process;
(d) concentration of a solution;
(e) processing rate or time;
(f) particle size analysis;
(g) bulk/tap density;
(h) pH determination;
(i) moisture content.
Product containers and closures
(a) quality and standards, if specified;
(b) manufacturing license number/drug master file number (whichever applicable), batch number;
(c) date of manufacture and date of expiry;
(d) method for container disposal (label shall give the methodology, if required);
(e) storage conditions, if specified and name and address of the manufacturer, if available.
PART II
PART II
REQUIREMENTS OF PLANT AND EQUIPMENT
External preparations.
(1) [Mixing and storage tanks preferably of stainless steel or any other appropriate material]
(2) Jacketted Kettle [stainless steel container] (steam, gas or electrically heated)
(3) Mixer (electrically operated)
(4) Planetary mixer
(5) A colloid mill or a suitable emulsifier
(6) A triple roller mill or an ointment mill
(7) Liquid filling equipment (electrically operated)
(8) Jar or tube filling equipment [***] .
[Note.
Oral liquid preparations.
(1) [Mixing and storage tanks preferably of stainless steel or any other appropriate material]
(2) Jacketted Kettle, Stainless steel tank (steam, gas or electrically heated)
(3) Portable stirrer (electrically operated)
(4) A colloid mill or a suitable emulsifier (electrically operated)
(5) Suitable filtration equipment (electrically operated)
(6) Semi-automatic/automatic bottle filling machine
(7) Pilfer-proof cap sealing machine
(8) Water distillation unit or deioniser
(9) Clarity testing inspection units
[Note.
Tablets.
(a) Mixing, Granulation and Drying section
(b) Tablet compression section
(c) Packaging section (strip/blister) machine wherever required)
(d) Coating section (wherever required)
(a) Granulation-cum-drying section
(1) Disintegrator and sifter
(2) Powder mixer
(3) Mass mixer/Planetary mixer/Rapid mixer granulator
(4) [Granulator wherever required]
(5) Thermostatically-controlled hot air oven with trays (preferably mounted on a trolley)/Fluid bed dryer
(6) Weighing machines
(b) Compression section
(1) Tablet compression machine, single/multi punch/rotatory
(2) Punch and dyes storage cabinets
(3) Tablet de-duster
(4) Tablet inspection unit/belt
(5) [Dissolution test apparatus wherever required]
(6) In-process testing equipment like single pan electronic balance, hardness tester, friability and disintegration test apparatus.
(7) Air-conditioning and dehumidification arrangement (wherever necessary)
(c) Packaging section
(1) Strip/blister packaging machine
(2) Leak test apparatus (vacuum system)
(3) Tablet counters (wherever applicable)
(4) Air-conditioning and dehumidification arrangement (wherever applicable) Area.-A minimum area of sixty square metres for basic installation and twenty square metres for Ancillary area is recommended for un-coated tablets.
(d) Coating section
(1) Jacketted kettle [stainless steel container or any other appropriate material] (steam, gas or electrically heated for preparing coating suspension)
(2) Coating pan (stainless steel)
(3) Polishing pan (where applicable)
(4) Exhaust system (including vacuum dust collector)
(5) Air-conditioning and dehumidification arrangement
(6) Weighing balance.
[Note.
[Note.
Powders.
(1) Disintegrator
(2) Mixer (electrically operated)
(3) Sifter
(4) Stainless steel vessels and scoops of suitable sizes
(5) Filling equipment [* * *]
(6) Weighing balance.
[Note.
Capsules.
(1) Mixing and blending equipment (electrically or power driven)
(2) Capsule filling units [* * *]
(3) Capsules counters (wherever applicable)
(4) Weighing balance
(5) Disintegration test apparatus
(6) Capsule polishing equipment
[Note.
Surgical dressing.
(1) Rolling machine
(2) Trimming machine
(3) Cutting equipment
(4) Folding and pressing machine for gauze
(5) Mixing tanks for processing medicated dressing
(6) Hot air dry oven
(7) Steam sterilizer or dry heat sterilizer or other suitable equipment
(8) Work tablets/benches for different operations.
Ophthalmic preparations.
(1) Thermostatically controlled hot air ovens (preferably double ended)
(2) Jacketted kettle/Stainless steel tanks (steam, gas or electrically heated)
(3) Mixing and storage tanks of stainless steel/Planetary mixer
(4) Colloid mill or ointment mill
(5) Tube filling and crimping equipment (semi-automatic or automatic filling machines)
(6) Tube cleaning equipment (air jet type)
(7) Tube washing and drying equipment, if required
(8) Automatic vial washing machine
(9) Vial drying oven
(10) Rubber bung washing machine
(11) Sintered glass funnel, seitz filter or candle (preferably cartridge and membrane filters)
(12) Liquid filling equipment (semi-automatic or automatic filling machines)
(13) Autoclave (preferably ventilator autoclave)
(14) Air-conditioning and dehumidification arrangement (preferably centrally air-conditioned and dehumidification system)
(15) Laminar air flow units.
[Note.
Pessaries and suppositories.
(1) Mixing and pouring equipment
(2) Moulding equipment
(3) Weighing devices.
(ii) In the case of pessaries manufactured by granulation and compression, the requirements as indicated under "item 3 of Tablet", shall be provided.
Inhalers and vitrallae.
(1) Mixing equipment
(2) Graduated delivery equipment for measurement of the medicament during filling
(3) Sealing equipment.
Repacking of drugs and pharmaceutical chemicals.
(1) Powder disintegrator
(2) Powder sifter (electrically operated)
(3) Stainless steel scoops and vessels of suitable sizes
(4) Weighing and measuring equipment
(5) Filling equipment (semi-automatic/automatic machine)
(6) Electric sealing machine.
Parenteral preparations.
(2) Containers and closures preparation area: This includes washing and drying of ampoules, vials, bottles and closures.
(3) Solution preparation area: This includes preparation and filtration of solution.
(4) Filling, capping and sealing area. This includes filling and sealing of ampoules and/or filling, capping and sealing of vials and bottles.
(5) Sterilization area.
(6) Quarantine area.
(7) Visual inspection area.
(8) Packaging area.
(a) Water management area,
(1) De-ionised water treatment unit.
(2) Distillation (multi-column with heat exchangers) unit.
(3) Thermostatically controlled water storage tank.
(4) Transfer pumps.
(5) Stainless steel service lines for carrying water into user areas.
(b) Containers and closures preparation area,
(1) Automatic rotary ampoule/vial/bottle washing machine having separate air, water, distilled water jets.
(2) Automatic closures washing machine.
(3) Storage equipment for ampoules, vials, bottles and closures.
(4) Dryer/sterilizer (double ended).
(5) Dust proof storage cabinets.
(6) Stainless steel benches/stools.
(c) Solution preparation area,
(1) Solution preparation and mixing stainless steel tanks and other containers.
(2) Portable stirrer.
(3) Filtration equipment with cartridge and membrane fitters/bacteriological filters.
(4) Transfer pumps
(5) Stainless steel benches/stools
(d) Filling, capping and sealing area,
(1) Automatic ampoule/vial/bottle filling, sealing and capping machine under laminar air flow work station.
(2) Gas lines (Nitrogen, Oxygen Carbon dioxide) wherever required.
(3) Stainless steel benches/stools.
(e) Sterilization area,
(1) Steam sterilizer (preferably with computer control for sterilization cycle alongwith trolley sets for loading/unloading containers before and after sterilization)
(2) Hot air sterilizer (preferably double ended)
(3) Pressure leak test apparatus
(f) Quarantine area,-
(1) Storage cabinets
(2) Raised platforms/steel racks.
(g) Visual inspection area,
(1) Visual inspection units (preferably conveyor belt type and composite white and black assembly supported with illumination)
(2) Stainless steel benches/stools
(h) Packaging area,
(1) Batch coding machine (preferably automatic)
(2) Labelling unit (preferably conveyor belt type)
(3) Benches/stools
(2) Areas for formulations meant for external use and internal use shall be separately provided to avoid mix-up.
(3) Packaging materials for large volume Parenteral shall have a minimum area of 100 square metres.
[Note.
Parenteral preparations in Plastic containers by Form-Fill-Seal/Blow-Fill-Seal technology.
(1) Water management area
(2) Solution preparation area
(3) Container moulding-cum-filling and sealing area
(4) Sterilization area
(5) Quarantine area
(6) Visual inspection area
(7) Packaging area
(a) Water management area,
(1) De-ionised water treatment unit
(2) Distillation unit (multi-column with heat exchangers)
(3) Thermostatically controlled water storage tank
(4) Transfer pumps
(5) Stainless steel service lines for carrying water into user areas.
(b) Solution preparation area,
(1) Solution preparation and storage tanks
(2) Transfer pumps
(3) Cartridge and membrane filters.
(c) Container moulding-cum-filling and sealing area,
(1) Sterile Form-Fill-Seal machine (all operations in one station with built-in Laminar air flow work station having integrated container output conveyor belt through pass box)
(2) Arrangement for feeding plastic granules through feeding-cum-filling tank into the machine.
(d) Sterilization area.-Super heated steam steriliser (with computer control for sterilization cycle along with trolley sets for loading/unloading containers for sterilization).
(e) Quarantine area.-Adequate number of platforms/racks with storage system.
(f) Visual inspection area.-Visual inspection unit (with conveyor belt and composite white and black assembly supported with illumination).
(g) Packaging area.-(1) Pressure leak test apparatus (pressure belt or rotating disc type).
(2) Batch coding machine (preferably automatic).
(3) Labelling unit (preferably conveyor belt type).
(2) Areas for formulations meant for external use and internal use shall be separately provided to avoid mix-up.
(3) Packaging materials for large volume Parenteral shall have a minimum area of 100 square metres.
[Note.
Note I.
Note II.
OLD LAW ▼
[SCHEDULE M]
(See rules 71, 74, 76 and 78)
GOOD MANUFACTURING PRACTICES AND REQUIREMENTS OF PREMISES, PLANT AND EQUIPMENT
Note.
PART I
PART I
GOOD MANUFACTURING PRACTICES-FACTORY PREMISES
General requirements
(i) compatible with other manufacturing operations that may be carried out in the same or adjacent premises;
(ii) adequately provided with the working spaces to allow orderly and logical placement of equipment and materials so as to,
(a) avoid the risk of mix-up between different drugs or with component, and
(b) control the possibility of cross contamination by other drugs or substances and avoid the risk of omission of any manufacturing or control step;
(iii) designed/constructed/maintained to prevent entry of insect and rodents. Interior surface (walls, floors and ceilings) shall be smooth and free from cracks, and permit easy cleaning and disinfection;
(iv) provided with adequate lighting and ventilation and if necessary air conditioning to maintain a satisfactory temperature and relative humidity that will not adversely effect the drug during manufacture and storage, or the accuracy of the functioning of the laboratory instruments;
(v) provided with underground drainage system in the processing area as far as possible. The sanitary fitting, and electrical fixtures in the manufacturing area shall be concealed and ventilation and air inlet points should be flushed with the wall as far as possible.
Requirement for sterile products manufacturing areas.
Working space and storage area
Health clothing and sanitation of workers
Medical service
(a) Adequate facilities for first aid;
(b) Medical examination of workers at the time of employment and periodical check up thereafter once in a year, with particular attention being devoted to freedom from infectious conditions. Records thereof shall be maintained; and
(c) Facility for vaccination or other exigencies. The licensee shall provide the services of a qualified physician for assessing the health status of personnel involved in the manufacturing and quality control of drugs.
Sanitation in the manufacturing premises
(i) The manufacture area shall not be utilised for any other purpose;
(ii) The manufacturing premises shall be maintained clean and in an orderly manner, free from accumulated waste, dust, debris, etc.;
(iii) Eating, chewing, smoking or any unhygienic practices shall not be permitted in the manufacturing area;
(iv) The manufacturing area shall not be used for general thoroughfare for personnel or for storage of materials, except for material being processed;
(v) A routine sanitation programme shall be drawn up and observed, which shall be properly recorded and which shall indicate.
(a) specific areas to be cleaned and cleaning intervals;
(b) cleaning procedure to be followed, including equipment and materials to be used for cleaning; and
(c) personnel assigned to and responsible for cleaning operations. Records of compliance in respect of sanitation shall be maintained for inspection.
Equipment
(i) achieve operational efficiency to attain the desired quality;
(ii) prevent physical, chemical and physiochemical change through surface contact;
(iii) prevent contact of any substance required for the operation of the equipments like lubricants, etc.;
(iv) facilitate through cleaning whenever necessary;
(v) minimise any contamination of drugs and their containers during manufacture.
(ii) Manufacturing equipment and utensils shall be thoroughly cleaned and if necessary sterilized in accordance with the written and specific instructions. When indicated all equipment should be disassembled and thoroughly cleaned to preclude the carry over of drug residences from previous operations/batches.
(iii) The accuracy and precision of the equipment used for specific filling shall be checked and confirmed at regular intervals and records of such checks shall be maintained.
(iv) The accuracy of premise filling shall be checked, confirmed and calibrated at regular intervals and the records of such checks shall be maintained.
(v) Equipment used for sterilization of drugs shall be filled with recording devices so as to monitor and evaluate the performance of the equipment and shall be calibrated and checked at regular intervals and records thereof shall be maintained.
(vi) Equipment used for critical steps in processing shall be monitored by devices capable of recording the permanent parameters or with alarm system to indicate malfunctions. These devices shall be calibrated and tested and records thereof shall be maintained.
Raw materials
(i) identified and their containers examined for damage and assigned control number;
(ii) stored at optimum temperatures and relative Humidity;
(iii) conspicuously labelled indicating the name of the materials, control number, name of the manufacturer and be specifically labelled "under test" or "approved" or "rejected";
(iv) systematically sampled by quality control personnel;
(v) tested for compliance with required standards of quality;
(vi) released from Quarantine by quality control personnel through written instructions;
(vii) so organised that stock rotation is on the basis of first in and first out principles in the storage areas;
(viii) so arranged that all rejected materials are conspicuously identified and are destroyed or returned to the suppliers as soon as possible and records maintained thereof.
Master formula records
(i) the patent or proprietary name of the product along with the generic name, if any, strength and the dosage form;
(ii) a description or identification of the final containers, packaging materials labels and closures to be used;
(iii) the identity, quantity and quality of each raw material to be used irrespective of whether or not it appears in the finished product. The permissible average that may be included in a formulated batch should be indicated;
(iv) a description of all vessels and equipment and the sizes used in the process;
(v) manufacturing and control instructions along with parameters for critical steps such as mixing, drying, blending, sieving, sterilizing the product, etc.;
(vi) the theoretical yield to be expected from the formulation at different stages for manufacture and permissible yield limits;
(vii) detailed instructions on precautions to be taken in manufacture and storage of drugs and of semi-finished products; and
(viii) the requirements of in-process quality control test and analysis to be carried out during each stage of manufacture including the designation of persons or departments responsible for the execution of such tests and analysis.
Batch manufacturing records-
Manufacturing operations and controls
(ii) Products not prepared under aseptic conditions are required to the free from pathogens, like Salmonella, E-Coli Pyocyanea, etc.
(iii) The contents of all vessels and containers used in manufacture and storage during various manufacturing stages shall be conspicuously labelled with the names of the product, batch No., batch size and stage of manufacture. Labels shall be attached to all mechanical manufacturing equipment during their operation with conspicuous labels bearing the name of the product and batch No.
(a) Carrying out manufacturing operations in separate building or adequately isolating the operation by total enclosure within the building;
(b) Using appropriate pressure differential in the process area;
(c) Providing a suitable exhaust system, and
(d) Designing laminar flow sterils air systems for sterile products;
(iv) The germicidal efficiency of UV lamps shall be checked and recorded indicating the burning hours or checked using intensity meter.
(v) The water for injection I.P. shall be either used immediately, or stored to prevent microbial growth at temperature of not less than 80°C in a jacketted stainless storage tank.
(vi) Individual containers of liquid orals, patenterals and ophthalmic solutions shall be examined against black/white background fitted with diffused light after filling to ensure freedom from contamination with foreign suspended matter.
(vii) Finished tables shall be inspected for presence of foreign matter besides an other defects.
(viii) Expert technical staff approved by the Licensing Authority shall check and compare actual yield against theoretical yield before finial distribution of the batch.