52. Placing of detonators.

(b) if the said railway servant is recalled, before the obstruction is removed, he shall leave down three detonators, on his way back, pick up the intermediate detonator.
(a) two detonators shall be placed on the line, by a railway servant appointed by station master in this behalf, about ten meters apart, and at least two hundred seventy meters outside the first stop signal;
(b) the station working rules shall prescribe the visibility test object from a distance of not less than one hundred eighty meters and can be a post erected for the purpose and lighted at night or light of a fixed colour light signal.
Note: also see rule 220
Note: