51. Duties of attendant of main mechanical ventilator.

(a) keep the ventilator running at the speed fixed by the manager; (b) examine the machinery and observe the pressure-recording or water gauge and the speedindicator at intervals of not more than one hour, and shall enter the readings of the indicator in a bound paged book kept for the purpose at the fan-house; (c) immediately report to his superior official any stoppage of, damage to, or defect or derangement in the machinery, or any unusual variation in the water-gauge or other indicators and shall also immediately report to him any unusual circumstances in regard to mine ventilation which may come to his notice; (d) not leave his place until relieved by a duly appointed substitute where the ventilator is continuously operated. 52. Duties of lamp room in-charge. - The person in-charge of a safety lamp-room shall-
(b) examine the machinery and observe the pressure-recording or water gauge and the speedindicator at intervals of not more than one hour, and shall enter the readings of the indicator in a bound paged book kept for the purpose at the fan-house;
(c) immediately report to his superior official any stoppage of, damage to, or defect or derangement in the machinery, or any unusual variation in the water-gauge or other indicators and shall also immediately report to him any unusual circumstances in regard to mine ventilation which may come to his notice;
(d) not leave his place until relieved by a duly appointed substitute where the ventilator is continuously operated.