Depth of seam from surface
Where the width of the galleries does not exceed 3.0 meters
Where the width of the galleries does not exceed 3.6 meters
Where the width of the galleries does not exceed 4.2 meters
Where the width of the galleries does not exceed 4.8 meters
The distance between centres of adjacent pillars shall not be
less than
(1)
(2)
(3)
(4)
(5)
Meters
Meters
Meters
Meters
Not exceeding 60 meters
12.0
15.0
18.0
19.5
Exceeding 60 but not exceeding 90 meters
13.5
16.5
19.5
21.0
Exceeding 90 but not exceeding 150 meters
16.5
19.5
22.5
25.5
Exceeding 150 but not exceeding 240 meters
22.5
25.5
30.5
34.5
Exceeding 240 but not exceeding 360 meters
28.5
34.5
39.5
45.0
Exceeding 360 meters
39.0
42.0
45.0
48.0
(a) if the distance between the centers of adjacent pillars is smaller than that specified in the table under sub-regulation (4), the pillars shall not be further reduced; or
(b) if the distance between the centers of adjacent pillar is not smaller than that specified in the table under sub-regulation (4), the pillars shall not be so reduced as to render such distance smaller than -
(i) the distance so specified; or
(ii) any distance required in this behalf by the Chief Inspector; and
(c) the height and width of the galleries shall not be further increased without the permission in writing of the Regional Inspector and subject to such conditions as he may specify therein.
Section 111 • The Coal Mines Regulations, 2017
111. Development work.
the-coal-mines-regulations-2017-sec-111.json
•
Section 111
{
"act_title": "The Coal Mines Regulations, 2017",
"act_slug": "the-coal-mines-regulations-2017",
"section_label": "Section",
"section": {
"number": "111",
"title": "111. Development work.",
"chapter": null,
"content": "Depth of seam from surface\nWhere the width of the galleries does not exceed 3.0 meters\nWhere the width of the galleries does not exceed 3.6 meters\nWhere the width of the galleries does not exceed 4.2 meters\nWhere the width of the galleries does not exceed 4.8 meters\nThe distance between centres of adjacent pillars shall not be\n\t\t\t\tless than\n(1)\n(2)\n(3)\n(4)\n(5)\nMeters\nMeters\nMeters\nMeters\nNot exceeding 60 meters\n12.0\n15.0\n18.0\n19.5\nExceeding 60 but not exceeding 90 meters\n13.5\n16.5\n19.5\n21.0\nExceeding 90 but not exceeding 150 meters\n16.5\n19.5\n22.5\n25.5\nExceeding 150 but not exceeding 240 meters\n22.5\n25.5\n30.5\n34.5\nExceeding 240 but not exceeding 360 meters\n28.5\n34.5\n39.5\n45.0\nExceeding 360 meters\n39.0\n42.0\n45.0\n48.0\n(a) if the distance between the centers of adjacent pillars is smaller than that specified in the table under sub-regulation (4), the pillars shall not be further reduced; or\n(b) if the distance between the centers of adjacent pillar is not smaller than that specified in the table under sub-regulation (4), the pillars shall not be so reduced as to render such distance smaller than -\n(i) the distance so specified; or\n(ii) any distance required in this behalf by the Chief Inspector; and\n(c) the height and width of the galleries shall not be further increased without the permission in writing of the Regional Inspector and subject to such conditions as he may specify therein.",
"footnote": "",
"is_definition": false,
"sort_order": 110
},
"prev_section": "110",
"next_section": "112"
}