194. Shotfirers.

(a) a manager's or overman's certificate or a sirdar's certificate together with a gas testing Certificate in case of belowground mines; and
(b) a manager's, overman's or a sirdar's certificate in the case of open cast working.
(a) the time normally require to prepare and fire a shot in accordance with the provisions of these regulations;
(b) the time required for that shotfirer to move between places where shots are fired;
(c) the assistance, if any, available to him in the performance of his said duties; and
(d) any other duties assigned to him, whether statutory or otherwise, and shall not in any case exceed-
(i) in the case of a gassy seam of second or third degree or a fiery seam, forty, if a single shot exploder is used and eighty; if a multi-shot exploder is used;
(ii) in the case of other seams fifty, if a single-shot exploder is used and hundred, if a multi-shot exploder is used; and
(iii) in the case of open cast mines sixty, if a single shot exploder is used or if blasting is done with ordinary detonators and one hundred and twenty, if a multi-shot exploder is used: