(a) No working or gallery shall be extended to a distance of more than 4.5 metres from the nearest ventilation connection unless the current of air is coursed upto a point within 4.5 metres of the face by means of fire resistant pipes, tubes brattices or other material.
(b) No narrow main or advance gallery shall be driven more than three meters ahead of the widened gallery.
(c) Every stopping between the main intake and the main return airways shall be substantially built and every air-crossing shall be constructed and maintained as to withstand the force of an explosion.
(d) The main air current shall be so split and coursed that an air current which ventilates a goaved out area, whether packed or unpacked, or any disused working shall not, except with the prior permission in writing of the Regional Inspector and subject to such conditions as he may specify therein, ventilate ally working where coal is being extracted.
(e) No major alteration shall be made in the system of ventilation except with the prior permission in writing of the Regional Inspector and subject to such conditions as he may specify therein:
(f) Except in an emergency, when a major alteration is made in the system of ventilation, only such persons as are engaged in making the alteration shall be present belowground.
Section 175 • The Coal Mines Regulations, 2011
175. General precautions in gassy mines.
the-coal-mines-regulations-2011-sec-175.json
•
Section 175
{
"act_title": "The Coal Mines Regulations, 2011",
"act_slug": "the-coal-mines-regulations-2011",
"section_label": "Section",
"section": {
"number": "175",
"title": "175. General precautions in gassy mines.",
"chapter": null,
"content": "(a) No working or gallery shall be extended to a distance of more than 4.5 metres from the nearest ventilation connection unless the current of air is coursed upto a point within 4.5 metres of the face by means of fire resistant pipes, tubes brattices or other material.\n(b) No narrow main or advance gallery shall be driven more than three meters ahead of the widened gallery.\n(c) Every stopping between the main intake and the main return airways shall be substantially built and every air-crossing shall be constructed and maintained as to withstand the force of an explosion.\n(d) The main air current shall be so split and coursed that an air current which ventilates a goaved out area, whether packed or unpacked, or any disused working shall not, except with the prior permission in writing of the Regional Inspector and subject to such conditions as he may specify therein, ventilate ally working where coal is being extracted.\n(e) No major alteration shall be made in the system of ventilation except with the prior permission in writing of the Regional Inspector and subject to such conditions as he may specify therein:\n(f) Except in an emergency, when a major alteration is made in the system of ventilation, only such persons as are engaged in making the alteration shall be present belowground.",
"footnote": "",
"is_definition": false,
"sort_order": 174
},
"prev_section": "174",
"next_section": "176"
}