114. Development work.

Table
Table
Depth of seam from surface
Where the width of galleries does
not exceed 3.0 meters
Where the width of galleries does
not exceed 3.6 meters
Where the width of the galleries
does not exceed 4.2 meters
Where the width of the galleries
does not exceed 4.8 meters
The distance between centres of adjacent pillars
shall not be less than
1
2
3
4
5
Metres
Metres
Metres
Metres
Not exceeding 60 metres
12.0
15.0
18.0
19.5
Exceeding 60 but not Exceeding 90 metres
13.5
16.5
19.5
21.0
Exceeding 90 but not exceeding 150 metres
16.5
19.5
22.5
25.5
Exceeding 150 but not exceeding 240 metres
22.5
25.5
30.0
34.5
Exceeding 240 but not exceeding 360 metres
28.5
34.5
39.0
45.0
Exceeding 360 metres
39.0
42.0
45.0
48.0
(a) If the distance between the centres of adjacent pillars is smaller than that specified in the table under sub-regulation (4), the pillars shall not be further reduced; or
(b) If the distance between the centres of adjacent pillar is not smaller than that specified in the table under sub-regulation (4), the pillars shall not be so reduced as to render such distance smaller than -
(i) the distance so specified; or
(ii) any distance required in this behalf by the Regional Inspector; and
(c) The height and width of the galleries shall not be further increased without the permission in writing of the Regional Inspector and subject to such conditions as he may specify therein.