(a) Each room of factory building shall, in relation to its size and the number of persons employed in it, be provided with an adequate number of exits for use in case of fire though not necessarily confined to such use, so positioned that each person will have a reasonably free and unobstructed passage from his work place to an exit.
(b) No exit intended for use in case of fire shall be less than 3 feet in width nor less than 6 feet, 6 inches in height.
(c) In the case of a factory building or part of a factory building of more than one storey and in which not less than twenty persons work at any one time, there shall be provided at least one substantial stairway permanently constructed either inside or outside the building and which affords direct and unimpeded access to ground level.
(d) In the case of a factory building or part of a factory building in which twenty or more persons work at any one time above the level of the ground floor, and wherein explosive or highly inflammable materials are used or stored, or which is situated below ground level, the means of escape shall include at least two separate and substantial stair ways permanently constructed either inside or outside the building and which afforded direct and unimpeded access to ground level.
(e) Every stairway in a factory which affords a means of escape in case of fire shall be provided with a substantial hand-rail which if the stairway has an open side shall be on that side, and if the stairway has two sides, such handrail shall be provided on both sides.
(a) At least one of the stairways provided shall be of fire-resisting materials.
(b) Every hoist-way or lift-way inside a factory building shall be completely enclosed with fire-resisting materials and all means of access to the hoist or lift shall be fitted with doors of fire-resisting materials :
(c) No fire escape stair shall be constructed at an angle greater than 45° from the horizontal.
(d) No part of a factory building shall be farther (along the line of travel) than 150 feet from any fire escape stair.
(e) No stairway shall be less than 45 inches in width.
Section 61 • The Assam Factories Rules, 1950
61. Means of escape in case of fire.
the-assam-factories-rules-1950-sec-61.json
•
Section 61
{
"act_title": "The Assam Factories Rules, 1950",
"act_slug": "the-assam-factories-rules-1950",
"section_label": "Section",
"section": {
"number": "61",
"title": "61. Means of escape in case of fire.",
"chapter": null,
"content": "(a) Each room of factory building shall, in relation to its size and the number of persons employed in it, be provided with an adequate number of exits for use in case of fire though not necessarily confined to such use, so positioned that each person will have a reasonably free and unobstructed passage from his work place to an exit.\n(b) No exit intended for use in case of fire shall be less than 3 feet in width nor less than 6 feet, 6 inches in height.\n(c) In the case of a factory building or part of a factory building of more than one storey and in which not less than twenty persons work at any one time, there shall be provided at least one substantial stairway permanently constructed either inside or outside the building and which affords direct and unimpeded access to ground level.\n(d) In the case of a factory building or part of a factory building in which twenty or more persons work at any one time above the level of the ground floor, and wherein explosive or highly inflammable materials are used or stored, or which is situated below ground level, the means of escape shall include at least two separate and substantial stair ways permanently constructed either inside or outside the building and which afforded direct and unimpeded access to ground level.\n(e) Every stairway in a factory which affords a means of escape in case of fire shall be provided with a substantial hand-rail which if the stairway has an open side shall be on that side, and if the stairway has two sides, such handrail shall be provided on both sides.\n(a) At least one of the stairways provided shall be of fire-resisting materials.\n(b) Every hoist-way or lift-way inside a factory building shall be completely enclosed with fire-resisting materials and all means of access to the hoist or lift shall be fitted with doors of fire-resisting materials :\n(c) No fire escape stair shall be constructed at an angle greater than 45° from the horizontal.\n(d) No part of a factory building shall be farther (along the line of travel) than 150 feet from any fire escape stair.\n(e) No stairway shall be less than 45 inches in width.",
"footnote": "",
"is_definition": false,
"sort_order": 63
},
"prev_section": "60",
"next_section": "61A"
}