887. Capacity of wards and cells.

Wards or
Workshops
Wards or
Workshops
Cells
Cells
Hospitals
Hospitals
Class of prisoner and locality of jail
Square feet of ground area
Cubic feet of air space.
Square feet of lateral ventilation
Square feet of ground area
Cubic feet of air space.
Square feet of lateral ventilation
Square feet of ground area.
Cubic feet of air space
Square feet of lateral ventilation.
Jails In The Plains.
Jails In The Plains.
Indians
45
540
12
96
1248
15
54
702
12
Note 1. - In calculating the cubic-space no account should be taken of any air space above 13 feet and in no case should the height exceed 15 feet.
Note 1.
Note 2. - No building should be nearer than 16 feet to an enclosure wall.
Note 2.
Note 3. - Lateral ventilation openings in barracks and hospital wards should be placed between the berths and should extend down to the floor level. Openings will only be fitted with iron-gratings.
Note 3.
Note 4. - Shutters for Doors & Windows shall be provided to the barracks, cells and hospitals in jails to protect the prisoners from rain and cold. The shutters will be fixed outside the iron gratings.
Note 4.
Note 5. - Each barrack should be provided with a cage latrine as per Plan No. 3 of the Report of the Indian Jails Committee 1919-1920. A verandah should also be provided at least on one side of each barrack for use by the prisoners when eating their meals and for holding classes.
Note 5.
Note 6. - Berths 6' x 2' should be provided in all barracks and in ground floor cells and must not be provided in condemned cells. These will be 18" high on the ground floor, but in upper floors the height can be reduced to 6" or the berths made of hollow construction.
Note 6.
Note 7. - Arrangements of two locks are required on condemned cells, but single lock is all that is required for other cells. Combined locking arrangements for cells are unnecessary.
Note 7.