29. Development including land sub-division and plot development for industrial development.

(i) the width of every new street, public or private, intended for use as a cart or carriage way giving access to or through an organized industrial area with not less than six constituent units, shall be minimum 10 meters:
(ii) the minimum size of industrial plot abutting street shall be 400 sq. meters in extent with a width of not less than 15 meters:
(iii) in industrial layouts a place for installation of transformer shall be provided in consultation with the Chief Electrical Inspector or an officer authorized by him;
(iv) the approval of the Chief Town Planner or an officer authorized by him shall be obtained for the layout of industrial streets and land sub-division exceeding five plots;
Note:- For the purpose of these rules small industrial unit means an industrial unit classified as such by Government from time to time or an industrial unit not included in Schedule 1 of the Factories Act, 1948.
Chapter V
Occupancy