109A. Roof top Rain Water harvesting Arrangements.

(i) Group AI
residential (with floor area of100 sq.m or more
and plot area of 200or more)
(ii) Group A2
Special Residential
(iii) Group B
Educational
(iv) Group C
Medical/Hospital
(v) Group D
Assembly
(vi) Group E
Office/Business
(vii) G1 and G2
Industrial (only for workshops, assembly plants
laboratories, dr6y cleaning plants power plants Gas plants
Refineries diaries food processing units and any other occupancies
notified by the Government from time to time
(vii) Group GI
hazardous (automobile wash stall, Automobile
service Stations, Service Garages,with repairing facilities and
any other occupancies notified by the Government from time to
time.
(i) Roof catchment area
(ii) Roof gutters
(iii) Down pipe and first flush pipe arrangement
(iv) Filter unit and
(v) Storage tank with provision for drawing water and spillover
Group A1
25 liters/sqm of total floor area.
Group A2
25 liters/sqm of total floor area
Group B
50 liters/sqm of total floor area
Group C
50 liters/sqm of total floor area
Group D
50 liters/sqm of total floor area
Group E
50 liters/sqm of total floor area
Group G1 & G2
50 liters/sqm of total floor area
Group I(1)
25 liters/sqm of total floor area
(i) Roof catchment area
(ii) Roof gutters
(iii) Down pipe
(iv) Filter units
(v) Recharge well/percolation pit
Chapter XVII
Safety Provisions for High Rise Buildings