Haryana Municipal Drainage and Sanitation Bye-laws, 1977
Haryana Municipal Drainage and Sanitation Bye-laws, 1977
Sections
1. Short title and extent.
Section 12. Definitions.
Section 23. Intention to construct.
Section 34. Application to construct.
Section 45. Building plans.
Section 56. Block plan of premises.
Section 67. Cross section when to be provided.
Section 78. Description of work proposed.
Section 89. Commencement of works.
Section 910. Notice of covering up drains or other drainage work.
Section 1011. Notice and certificate of completion of work.
Section 1112. Application before connection with public sewer.
Section 1213. Connection with public sewer.
Section 1314. Inspection of work.
Section 1415. Minor alteration in case of emergency.
Section 1516. Carrying out of work.
Section 1618. Adequacy of water supply.
Section 1819. Maintenance.
Section 1920. Water borne sanitary installation.
Section 2021. Level of lowest storey.
Section 2122. Sanitary installations and execution of works to conform to P.W.D. specifications.
Section 2223. Drain to be air, smoke and water tight.
Section 2324. Net work of soil and waste water drainage to be kept separate.
Section 2425. Junctions.
Section 2526. Minimum requirements of sanitary fitments.
Section 2627. Water closet.
Section 2728. Urinals.
Section 2829. Laying out drains.
Section 2930. Material for drains and construction.
Section 3031. Drain connection for trade effluent.
Section 3132. Ventilation of drains.
Section 3233. Soil pipes and ventilating pipes.
Section 3334. Sizes and material for soil pipe, waste pipe, ventilating pipes and their installation.
Section 3435. Separation of soil pipes from rain water pipes.
Section 3536. Waste water pipes.
Section 3637. Manholes.
Section 3738. Provision of trap
Section 3839. Ventilation for floor traps.
Section 3940. Floor surrounding the floor trap.
Section 4041. Overflow pipe.
Section 4142. Pipes not to be exposed on external walls.
Section 4243. Testing of pipes.
Section 4344. Construction of open drains and surface channels.
Section 4445. Trap and silt catcher.
Section 4546. Drainage of houses having high plinth.
Section 4647. Paving ground surface.
Section 4748. Water closet not to be connected with open drain.
Section 4849. Bye laws for open drain etc.
Section 4950. Method of disposal.
Section 5051. Septic tank.
Section 5152. Absorption pits.
Section 5253. Sub-soil irrigation for disposal of effluent.
Section 5354. Drainage of roofs.
Section 5455. Drainage of courtyard.
Section 5556. Size of rain water pipes.
Section 5657. Materials of rain water pipes.
Section 5758. Drains for storm water constructed within the thickness of wall.
Section 5859. Service latrine, privy and service urinals.
Section 5960. Proximity to building.
Section 6061. Proximity for water supply.
Section 6162. Open drains to be provided for buildings not within 30 metres of a municipal drain.
Section 6263. Discharge from washing places.
Section 6364. Capacity of cesspool.
Section 6465. Ventilation of cesspool.
Section 6566. Cesspool for latrine to be separated.
Section 6667. Location of cesspool.
Section 6768. Construction of cesspool.
Section 6869. Floor of ashpits.
Section 6970. Floors of horse stables.
Section 7071. Channels for horse stables.
Section 7172. Gully traps for more stables.
Section 7273. Bye-laws for pipe drains to be complied with.
Section 7374. Floor for cattle stables.
Section 7475. Channel for cattle stables.
Section 7576. Catchpit for cattle stables.
Section 7677. Granting to be provided for catch pits.
Section 7778. Bye-laws for pipe drains to be complied with.
Section 7879. Registration of plumbers.
Section 7980. Renewal.
Section 8083. Penalties.
Section 8384. Repeal.
Section 84
haryana-municipal-drainage-and-sanitation-bye-laws-1977.json
•
81 Sections
•
Haryana
{
"id": 17030,
"slug": "haryana-municipal-drainage-and-sanitation-bye-laws-1977",
"title": "Haryana Municipal Drainage and Sanitation Bye-laws, 1977",
"short_title": "Haryana Municipal Drainage and Sanitation Bye-laws, 1977",
"act_number": "Published vide Haryana Government Notification No.",
"act_year": 1977,
"act_type": "STATE",
"location": "Haryana",
"law_status": "unknown",
"enactment_date": null,
"description": "Haryana Municipal Drainage and Sanitation Bye-laws, 1977",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "1. Short title and extent.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "2",
"title": "2. Definitions.",
"chapter": null,
"content": "(i) \"Act\" means the Haryana Municipal Act, 1973 ;\n(ii) \"anti-syphonage\" means a device to preserve the water seal in traps by providing ventilation ;\n(iii) \"cess pool\" includes a septic tank, a settlement tank or other tank for the reception or disposal of foul matter from a premises ;\n(iv) \"connection\" means the junction of a foul water drain, surface water drain or sewer from a building or buildings with a public sewer ;\n(v) \"drain\" means a line of pipes including all fittings and equipment such as manholes, inspection Chambers, traps, gullies and floor traps used for the drainage of a building or a number of buildings or yards appurtenant to the building, within the same curtilage and includes a house drain ;\n(vi) \"drainage\" means removal of any liquid by a system constructed for the purpose. Drainage work means the design and construction of system of drainage;\n(vii) \"drop connection\" means a branch drain of which the last length of piping of the incoming drain, before connection to the sewer, is vertical ;\n(viii) \"interceptor manhole or interceptor chamber\" means a manhole incorporating an intercepting trap and providing means of access thereto and equipped with a fresh air inlet on the up stream end of the trap and a vent column on the down stream side;\n(ix) \"invert\" means the lowest point of the interior of a sewer or drain at any cross section. In a manhole chamber, the channel in the floor of the chamber which carries the flow of sewage through the manhole ;\n(x) \"licensed plumber\" means a person registered by the municipal committee for the purpose of these bye-laws, and possessing qualifications as given in the Schedule-I;\n(xi) \"manhole\" means an opening by which a man may enter or leave a drain or a sewer or other closed structure for inspection, cleaning and other maintenance operations fitted with a suitable cover ;\n(xii) \"privy\" means a place set apart for defecating or urinating or both, together with the structure comprising such place, the receptacle therein for human excreta and the fittings and apparatus, if any, connected therewith and includes a closet of the dry type, an acquex privy, a latrine and a urinal ;\n(xiii) \"rain water pipe\" shall mean a pipe or drain situated wholly above ground and used or constructed to be used solely for carrying rain water directly from roof surfaces ;\n(xiv) \"rodding eye\" means an access having a removable cover to enable obstructions to be cleared by means of a drain rod ;\n(xv) [water seal latrine] and \"service urinal\" shall mean respectively a latrine and urinal from which the excreta are removed by manual agency and not by water carriage system;\n(xvi) \"sewer\" shall mean a closed drain, provided for the purposes of carrying the liquid waste of a household or community including human excreta otherwise known as sewage, constructed and maintained by the Government or by a local authority;\n(xvii) \"soakage pit\" means a pit suitably prepared to receive soil water or partially treated sewage for seepage into surrounding ground ;\n(xviii) \"soil waste\" means the discharge from water closets, urinals, slop sinks, stable or cowshed gullies and similar appliances ;\n(xix) \"soil pipe\" means a pipe which receives the discharge from soil fitments such as water closets, urinals, slop sinks, etc. ;\n(xx) \"storm water drain\" means any open channel or conduit whether within private premises or public premises and reserved exclusively for conveyance of rain water;\n(xxi) \"sub-oil water drain\" means a drain used or constructed to be used solely for conveying to any sewer (either directly or through another drain) water that may percolate from the sub-soil ;\n(xxii) \"surface water drain\" means a drain conveying surface water including storm water;\n(xxiii) \"trade effluent\" means the discharge, other than soil or waste from any manufacturing process ;\n(xxiv) \"vent\" means a pipe line installed to provide flow of air to or from a drainage system or to provide circulation of air within such system to protect traps seals from syphonage and back flow ;\n(xxv) \"ventilating pipe\" means a pipe which provides a safe outlet into the atmosphere for the foul gases in the drain or sewer ;\n(xxvi) \"waste water (Sullage)\" means spent water from baths, wash basins, sinks and similar appliances which do not contain human or animal excreta ;\n(xxvii) \"waste pipe\" means the pipe which receives waste water from the corresponding sanitary appliances ;\n(xxviii) \"water-borne sanitary installations\" means sanitary fitments such as urinals, latrine, water closets, bidet, slop sink, hospital, sanitary fitting such as bed pan and urinal bottle sink or other similar fittings, the solid or liquid waste from which is intended to be discharged by a flush of water, and shall include all manholes, strapes, gullies, soil pipes, waste pipes, ventilating pipes, anti-syphonage pipes and drains communicating with sewers ;\n(xxix) \"water closet\" means a closet which has a separate fixed receptacle connected to a drainage system and has separate provision of flushing from supply of clean water either by the operation of a mechanism or by automatic action:\n(xxx) \"Executive Officer\" and \"Secretary\" shall mean the Officer, acting for the time being, as Executive Officer, or Secretary of the committee and shall include an Assistant Secretary, if any ;\n(xxxi) \"two pipe system\" means the system in which soil and waste pipes are distinct and separate the soil pipes being connected to drain direct and waste pipes through a trapped gully. All traps of all sanitary appliances are completely ventilated in this system ;\n(xxxii) Words and expressions used herein and not defined in these bye-laws shall have the meanings assigned to them in the Act.",
"footnote": "",
"is_definition": true,
"sort_order": 1
},
{
"number": "3",
"title": "3. Intention to construct.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 2
},
{
"number": "4",
"title": "4. Application to construct.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "5",
"title": "5. Building plans.",
"chapter": null,
"content": "(a) every floor of any building in connection with which the pipes or drains are to be used.;\n(b) the position, levels and arrangements of the several parts of such building including the roofs thereof ;\n(c) the whole of the intended new drains with their proposed sizes and gradients in figures;\n(d) the levels of the ground surface and depths of the proposed drains ; and\n(e) the position of every manhole, gully, soil pipe, ventilating pipe, rain water pipe, water closet, urinal, latrine, bath, lavatory, sink, trap or other appliances on the premises proposed to be connected with any drain and in a distinctive colour in respect of drains, etc-, mentioned in caused [e] This information shall be shown complete both on elevations and sections as well as in plans; provided always that in the case of an alteration or addition to an existing building this condition shall be deemed to be satisfied if the plans convey sufficient information for the proposals to be readily identified with the original or subsequently sanctioned plans.\n(a) the position of all windows and other openings in the building ;\n(b) the height and position of all chimneys in the building within a distance of fifteen feet from the open end of a soil pipe or ventilating pipe ;\n(c) in detail, the nature of all sanitary connections including the manner of disposal of rain water and its discharge to the storm water drain ;\n(d) the scale to which the plan is drawn ;\n(e) the disposal of bathroom and kitchen and connections to the waste and soil pipes and the nature of the connection of the soil pipe to the sewer with a suitable intercepting chamber, when such chamber has been required by the committee by a general or special order.",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "6",
"title": "6. Block plan of premises.",
"chapter": null,
"content": "(i) 1 to 200 for sites up to 1,000 square metres ;\n(ii) 1 to 400 for sites above 1,000 square metres and under 4,500 square metres ;\n(iii) 1 to 800 for sites of 4,500 square metres and above; and shall show the following, namely :-\n(a) the block plan of the building and the position of all other buildings on the premises and such parts of adjoining buildings as may be affected by the proposed works ;\n(b) the names of the street adjoining to premises ;\n(c) the difference in level between the lowest floor of the building and of any courtyard and of the adjoining ground ;\n(d) the lines, size and gradients of all drains and surface drains, if any ;\n(e) the scale of the plan ; and\n(f) the drains and other appliances shown by distinctive colours :",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "7",
"title": "7. Cross section when to be provided.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "8",
"title": "8. Description of work proposed.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "9",
"title": "9. Commencement of works.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "10",
"title": "10. Notice of covering up drains or other drainage work.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "11",
"title": "11. Notice and certificate of completion of work.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "12",
"title": "12. Application before connection with public sewer.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "13",
"title": "13. Connection with public sewer.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "14",
"title": "14. Inspection of work.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "15",
"title": "15. Minor alteration in case of emergency.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "16",
"title": "16. Carrying out of work.",
"chapter": null,
"content": "[17. List of licensed plumbers.",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "18",
"title": "18. Adequacy of water supply.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "19",
"title": "19. Maintenance.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "20",
"title": "20. Water borne sanitary installation.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 18
},
{
"number": "21",
"title": "21. Level of lowest storey.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 19
},
{
"number": "22",
"title": "22. Sanitary installations and execution of works to conform to P.W.D. specifications.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 20
},
{
"number": "23",
"title": "23. Drain to be air, smoke and water tight.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 21
},
{
"number": "24",
"title": "24. Net work of soil and waste water drainage to be kept separate.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 22
},
{
"number": "25",
"title": "25. Junctions.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 23
},
{
"number": "26",
"title": "26. Minimum requirements of sanitary fitments.",
"chapter": null,
"content": "(a) one bath room provided with a tap ;\n(b) one water close ; and\n(c) one Nahani or sink either in the floor or raised from the floor. Where only one water closet is provided in a dwelling, the bath and water closet shall be separately accommodated.\n(a) one water tap with draining arrangements in each tenement ;\n(b) one water closet and one bath for every two tenements ; and\n(c) water taps in common bath rooms and common closets.",
"footnote": "",
"is_definition": false,
"sort_order": 24
},
{
"number": "27",
"title": "27. Water closet.",
"chapter": null,
"content": "(a) have an internal diameter of not less than 50 mm. ;\n(b) be connected with the arm of the soil pipe at a point not less than 7.5 cm. and not more than 30 cm. from the highest part of the trap, on that side of the water seal which is nearer to the soil pipe and in the direction of the flow ; and\n(c) either have an open and as high as the top of soil pipe or be carried into a soil pipe at a point not less than 1.5 metres above the highest connection of the soil pipe.",
"footnote": "",
"is_definition": false,
"sort_order": 25
},
{
"number": "28",
"title": "28. Urinals.",
"chapter": null,
"content": "(i) the urinals shall be provided with a basin, stall, trough or other suitable receptacle or receptacle of non-absorbent material ;\n(ii) in a urinal constructed or adapted to be used for receiving any urine or liquid filth for conveyance to any sewer, an efficient syphon capable for maintaining the urinal and any drain or waste pipe in connection therewith shall be provided ;\n(iii) no trap of the kind known as a bell trap, a dip trap or D trap nor any non self cleansing trap shall be constructed or fixed in or in connection with the urinal;\n(iv) it shall be provided with suitable automatic flushing cistern for effectively flushing and cleansing the receptacle provided ;\n(v) the outlet from the receptacle or receptacles shall be provided with an efficient gratings;\n(vi) the discharging or flushing capacity shall not be less than one gallon of water for each connection basin, or each with or length not exceeding 70 cms. of stall or trough respectively;\n(vii) it shall be capable of being filled or charged with water within a period of twenty-five minutes or such less period as will permit, while the urinal is in use or available for use a flushing operation of sufficient frequency to ensure the maintenance of such basin, stall or trough in a state of cleanliness;\n(viii) It shall be fitted with a suitable automatic flushing cistern connected to the urinal basin, stall or trough, by an adequate flush pipe or pipes of the lead, copper, iron or other equally suitable material having a minimum internal diameter of 12 mm and fitted with a suitable spreader or sparger pipe so as effectively to distribute the water over the internal surface of every basin, stall or trough ;\n(ix) no part of the urinal apparatus shall be directly connected with a supply or distributing pipe ;\n(x) when a room is used only as a urinal it will have a minimum floor area 1.25 square metre and a minimum width of 1.6 metre. The floor and the walls of any room which is used as urinal shall be constructed of an impervious and non-absorbent material to a height of one metre;\n(xi) no urinal shall be constructed so as to make it approachable directly from any room used for the purpose of human habitation or for the manufacture/preparation or storage of food for consumption or as a factory, workshop or work place until and unless a properly ventilated passage of 1 metre is provided ;\n(xii) the floor of all urinals on the ground floor shall be raised at least 15 cms. above the outside grounds ;\n(xiii) if the urinal can be entered from within the buildings and is constructed to discharge into a soil pipe which also received the discharge from another urinal, or from a water-closet, bidet or lavatory basin, the trap of the urinal shall be ventilated by a pipe which shall-\n(a) be of internal diameter of not less than that of the trap or 50 mm whichever is less;\n(b) be connected with the waste pipe from the urinal at a point not less than 7.5 cm. and not more than 30 cm. from the highest part of the trap on that side of the water seal which is nearer to the waste pipe ; and\n(c) either have an open and as high as the top of the waste pipe or be carried into a waste pipe at a point not less than 1.5 metres above the highest connection to the waste pipe:\nLaying out Installation of Drain Pipes",
"footnote": "",
"is_definition": false,
"sort_order": 26
},
{
"number": "29",
"title": "29. Laying out drains.",
"chapter": null,
"content": "(a) be of a suitable size, and if it is intended for the conveyance of soil water or waste water, shall have an internal diameter of not less than 10.0 mm ;\n(b) be laid with a suitable gradient, and where practicable, in a direct line. The standard gradient shall be 1 in 40 for a 100 mm drain and in 80 for 150 mm drain. The maximum and minimum gradients shall respectively be 1 in 20 and 1 in 80 for a 100 mm drain and 1 in 40 and 1 in 140 respectively for a 150 mm drain ;\n(ii) a drain shall not be constructed so as to be within or under any building, except in a case where any other situation is impracticable ;\n(iii) where any such drain or part thereof is constructed within or under any building, such part thereof shall be laid or fixed in a direct line, and where practicable, be provided with adequate means of access ;\n(iv) where such drain is laid under a wall, it shall be protected at that part which is under the wall by means of a relieving arch, flag stone, iron or any other support which shall not bear in the drain and shall be of sufficient size and strength to prevent any [blockade or damage] to such drain ;\n(v) a drain shall not be constructed in such a manner that there shall be within a building any inlet to such drain except such inlet as may be necessary from any sanitary fittings or any sanitary installation connected directly to such drain ;\n(vi) every branch drain shall join any other drain obliquely in the direction of the flow of that drain and as near as practicable to the invert thereof ; and\n(vii) every inlet other than a ventilating pipe to such drain shall be properly trapped by a suitable and efficient trap, and such trap shall be formed and fixed so as to be capable of maintaining a water seal of ;-\n(a) 50 mm where such inlet has an internal diameter of less than 80 mm ;\n(b) 75 mm where such inlet has an internal diameter of more than 80 mm ;\n(viii) every trapped gully shall be covered with a grating the bars of which shall be not more than 10 mm apart ;\n(ix) have a suitable and efficient intercepting trap, when such trap has been required by the committee by a general or special order, with a water seal at least 100 mm at a point as far as may be practicable from the building and as near as may be practicable to the point at which the drain shall be connected with the sewer, which shall be provided to such a drain before connecting it. Such a trap shall be provided with a raking or leaning arm, fitted with a secure and suitable stopper as a means of access shall be-\n(a) constructed so as to be water-tight ;\n(b) fitted with a suitable cover at the level of adjoining ground surface; and\n(c) if placed within a building fitted with an airtight manhole cover.",
"footnote": "",
"is_definition": false,
"sort_order": 27
},
{
"number": "30",
"title": "30. Material for drains and construction.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 28
},
{
"number": "31",
"title": "31. Drain connection for trade effluent.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 29
},
{
"number": "32",
"title": "32. Ventilation of drains.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 30
},
{
"number": "33",
"title": "33. Soil pipes and ventilating pipes.",
"chapter": null,
"content": "(i) easily accessible throughout its course and adequately protected where necessary from damage ;\n(ii) of an internal diameter of not less than 100 mm ;\n(iii) circular ;\n(iv) carried upwards to such a height and in such manner so as to prevent any nuisance or injury or danger to health arising from the omission of foul air from such pipe, the minimum height being 150 cm. above flat roof or terrace parapet whichever is higher or top of the window within a horizontal distance of 3 metres and be fitted with suitable cowl. In case the adjacent building is taller, the ventilating pipe shall be carried higher than the roof of the adjacent building wherever it is possible.",
"footnote": "",
"is_definition": false,
"sort_order": 31
},
{
"number": "34",
"title": "34. Sizes and material for soil pipe, waste pipe, ventilating pipes and their installation.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 32
},
{
"number": "35",
"title": "35. Separation of soil pipes from rain water pipes.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 33
},
{
"number": "36",
"title": "36. Waste water pipes.",
"chapter": null,
"content": "(i) not discharge as to cause dampness in wall or foundation of a building ;\n(ii) it discharges into a drain it shall be disconnected from the drain by a trapped gully with a suitable grating above the level of the water in the trap ;\n(iii) if it is more than 1.80 metres in length, be provided with a suitable trap.",
"footnote": "",
"is_definition": false,
"sort_order": 34
},
{
"number": "37",
"title": "37. Manholes.",
"chapter": null,
"content": "(a) for depth of 0.8 m. or less\n0.75 x 0. 75 m.\n(b) for depths between 0.8 m. and 2.1 m.\n.. 1.2 x 0.9 m.\n(c) for depths more than 2.1 m.\nrectangular chamber with minimum internal dimensions of 1.1 x\n\t\t\t0.9 m.",
"footnote": "",
"is_definition": false,
"sort_order": 35
},
{
"number": "38",
"title": "38. Provision of trap",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 36
},
{
"number": "39",
"title": "39. Ventilation for floor traps.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 37
},
{
"number": "40",
"title": "40. Floor surrounding the floor trap.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 38
},
{
"number": "41",
"title": "41. Overflow pipe.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 39
},
{
"number": "42",
"title": "42. Pipes not to be exposed on external walls.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 40
},
{
"number": "43",
"title": "43. Testing of pipes.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 41
},
{
"number": "44",
"title": "44. Construction of open drains and surface channels.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 42
},
{
"number": "45",
"title": "45. Trap and silt catcher.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 43
},
{
"number": "46",
"title": "46. Drainage of houses having high plinth.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 44
},
{
"number": "47",
"title": "47. Paving ground surface.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 45
},
{
"number": "48",
"title": "48. Water closet not to be connected with open drain.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 46
},
{
"number": "49",
"title": "49. Bye laws for open drain etc.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 47
},
{
"number": "50",
"title": "50. Method of disposal.",
"chapter": null,
"content": "(a) into absorption pits ; or\n(b) by sub-soil irrigation :",
"footnote": "",
"is_definition": false,
"sort_order": 48
},
{
"number": "51",
"title": "51. Septic tank.",
"chapter": null,
"content": "(i) at a distance of less than 25 metres, from a dwelling house or any other building used for human habitation or for work or recreation or within a public thoroughfare;\n(ii) within 30 metres from any percolation well, water-course or stream used or likely to be used for drinking or domestic purposes or for manufacture or preparation of any article of food or drink for human consumption and it shall be readily accessible so as to permit cleaning operations being carried out without interference with the operation of any water borne sanitary installation as a whole.",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
{
"number": "52",
"title": "52. Absorption pits.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 50
},
{
"number": "53",
"title": "53. Sub-soil irrigation for disposal of effluent.",
"chapter": null,
"content": "Storm Water Drainage",
"footnote": "",
"is_definition": false,
"sort_order": 51
},
{
"number": "54",
"title": "54. Drainage of roofs.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 52
},
{
"number": "55",
"title": "55. Drainage of courtyard.",
"chapter": null,
"content": "(b) An outer courtyard is a courtyard in which at least one of the walls faces out into the open.",
"footnote": "",
"is_definition": false,
"sort_order": 53
},
{
"number": "56",
"title": "56. Size of rain water pipes.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 54
},
{
"number": "57",
"title": "57. Materials of rain water pipes.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 55
},
{
"number": "58",
"title": "58. Drains for storm water constructed within the thickness of wall.",
"chapter": null,
"content": "Dry System-Service Latrine, Privy Service Urinals",
"footnote": "",
"is_definition": false,
"sort_order": 56
},
{
"number": "59",
"title": "59. Service latrine, privy and service urinals.",
"chapter": null,
"content": "(i) It shall have only direct entrance which shall be external.\n(ii) For the purpose of cleaning, access shall be provided to all [water seal latrines] and service urinals from a public road and such accesses shall in no case be less than 75 cm. wide through a building.\n(iii) Every [water seal latrine] should have a minimum floor area of 2 sq. metres and a minimum width of 1 metre.\n(iv) It shall not be less than 30 metres from any wall, spring, or stream of water, used or likely to be used by human beings for drinking or domestic purposes, for the manufacture or preparation of articles of food or drink for human consumption, or for the cleaning of vessels, and otherwise in such a position so as not to render any such water liable to pollution.\n(v) It shall be provided with a sufficient opening for lighting and ventilating as near the top as practicable and communicating directly with the external air.\n(vi) Every [water seal latrine] or service urinal shall be so constructed that when the outer door thereof is open the seat shall not be visible from a road or other public place.\n(vii) The floor shall be of non-absorbent material, which shall in every part, including the part beneath the seat, be not less than 75 mm. above the surface of the adjoining ground level and have a fall or inclination towards the exterior of the room of not less than 1 in 10.\n(viii) The receptacle for faecal matter in the case of [water seal latrine] , etc. (hereinafter in these bye-laws called the \"the receptacle\") shall be of non-absorbent material.\n(ix) The receptacle shall be of a sufficient capacity so as to hold excreta, etc. for one day.\n(x) The [water seal latrine] and service urinal walls shall be rendered with a non-absorbent material such as cement plaster (1 : 2) upto a height of at least 1.20 metres above the floor level,\n(xi) The latrine and urinal slope to a drain should be provided in such a way that the liquid will flow off quickly.\n(xii) Every [water seal latrine] and service urinal shall be provided with a drain which shall be constructed of glazed pipes or other impervious material and shall connect the floor of the latrine or urinal with a public drain or if in the opinion of the committee this is not practicable, with a property designed soakage pit, which shall further be provided as per the provisions of these bye-laws.\nCesspool",
"footnote": "",
"is_definition": false,
"sort_order": 57
},
{
"number": "60",
"title": "60. Proximity to building.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 58
},
{
"number": "61",
"title": "61. Proximity for water supply.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 59
},
{
"number": "62",
"title": "62. Open drains to be provided for buildings not within 30 metres of a municipal drain.",
"chapter": null,
"content": "(1) The house drain if open, shall discharge by means of a 15 cm. by 15 cm. stoneware gully trap into the cesspool.\n(2) All cesspools shall be closely covered and fitted with a cast iron airtight frame and cover, provided with adequate means of ventilation.\n(3) All cesspools shall be provided with adequate means of access for cleaning each manhole being fitted with suitable airtight cast iron frame and cover.",
"footnote": "",
"is_definition": false,
"sort_order": 60
},
{
"number": "63",
"title": "63. Discharge from washing places.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 61
},
{
"number": "64",
"title": "64. Capacity of cesspool.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 62
},
{
"number": "65",
"title": "65. Ventilation of cesspool.",
"chapter": null,
"content": "(a) carried at least 4.50 m. higher than any skylight or window situated within a distance of 12 m. therefrom.\n(b) carried at least 1.50 m. higher than eave or the roof, if affixed to a wall supporting the eave ; and\n(c) erected or affixed so as to cause the least practicable nuisance or inconvenience to the inhabitants of the neighbourhood.",
"footnote": "",
"is_definition": false,
"sort_order": 63
},
{
"number": "66",
"title": "66. Cesspool for latrine to be separated.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 64
},
{
"number": "67",
"title": "67. Location of cesspool.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 65
},
{
"number": "68",
"title": "68. Construction of cesspool.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 66
},
{
"number": "69",
"title": "69. Floor of ashpits.",
"chapter": null,
"content": "Horse Stables (Public or Private)",
"footnote": "",
"is_definition": false,
"sort_order": 67
},
{
"number": "70",
"title": "70. Floors of horse stables.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 68
},
{
"number": "71",
"title": "71. Channels for horse stables.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 69
},
{
"number": "72",
"title": "72. Gully traps for more stables.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 70
},
{
"number": "73",
"title": "73. Bye-laws for pipe drains to be complied with.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 71
},
{
"number": "74",
"title": "74. Floor for cattle stables.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 72
},
{
"number": "75",
"title": "75. Channel for cattle stables.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 73
},
{
"number": "76",
"title": "76. Catchpit for cattle stables.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 74
},
{
"number": "77",
"title": "77. Granting to be provided for catch pits.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 75
},
{
"number": "78",
"title": "78. Bye-laws for pipe drains to be complied with.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 76
},
{
"number": "79",
"title": "79. Registration of plumbers.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 77
},
{
"number": "80",
"title": "80. Renewal.",
"chapter": null,
"content": "81.\n82.",
"footnote": "",
"is_definition": false,
"sort_order": 78
},
{
"number": "83",
"title": "83. Penalties.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 79
},
{
"number": "84",
"title": "84. Repeal.",
"chapter": null,
"content": "Form A\nForm A\n( See Bye-laws 4 )\nMunicipal Committee ______________________\n(To be submitted in duplicate)\nDrainage of Premises\nApplication for Drainage of Premises\n( See Bye-law 4 )\nNote :- The application shall be signed by the owner of the premises and shall be countersigned by the licensed plumber.\nForm B\nForm B\n(Annexure to Form A)\n( See Bye-law 8 )\nMunicipal Committee............\n(To be submitted in triplicate)\nDrainage of Premises\n(To be filled in by applicant or person/s depositing plans)\nN.B.-\n(a) Main Sewage Drains\n{\nfall size\n(b) Branch Sewage Drains\n(c) Materials,\n(d) Method of joining.\n(a) Method of Bedding.\n(b) Thickness and width of beds of concrete.\n(c) Thickness of concrete round pipes.\nBath waste pipes.\nSink.\nWater-closet traps.\nGrease traps.\nSlop sink.\nUrinal.\nOthers.\nThickness of walls.\nDescription of bricks.\nDescription of rendering channels.\nDescription of invert channels.\nDepth of chambers.\nSize and description of cover and manner of fixing.\n(a) Position\nHeight above nearest ground level,\n(b) Outlet shaft position of terminal at top.\n(a) Lead and Iron pipes.\n(b) Lead pipe of trap with cast iron pipe.\n(c) Stoneware pipe or trap with lead pipe.\n(d) Lead soil pipe or trap with stoneware pipe or trap.\n(e) Cast iron pipe with stoneware drain.\n(f) Stoneware trap with cast iron soil pipe.\n(a) At or above ground level.\nApproached from.\nFloor material.\nFloor fall towards door.\nSize of window made to open.\nPosition of same.\nMeans of constant ventilation.\nPosition of same.\n(b) Water closet apparatus :-\nDescription of pan, basin, etc.\n{\nkind Capacity\nFlushing cistern.\nMaterial of flushing pipe.\nFlushing of pipe.\nInternal diameter.\nUnion with basin.\n(b) Capacity and position of water storage tanks.\n(c) Size and number of draw off taps and whether taken off storage tanks or direct from main supply.\n(d) Details of draw off taps i.e. whether they are of plain screw down pattern or \"waste note.\"\nMaterials Diameter Weight Method of Joining.\nSub-Soil drains\nMain Sewage drains\nBranch Sewage drains\nSoil Pipes\nVentilating Pipes\nOther than soil pipes\nWaste pipes\nRain water pipes\nAnti syphon pipes\nSignatures of the Licensed Plumber.\nName and address of the Licensed Plumber.\nForm 'C'\nForm 'C'\n( See Bye-law 10 )\nMunicipal Committee_________________\n(To be submitted in duplicate)\nDrainage Of Premises\nForm For Intimating Intention To Cover Up The Work\nForm For Intimating Intention To Cover Up The Work\n{\nSignature of\n\t\t\tperson incharge of the drainage of premises\n}\n{ Name of\n\t\t\tthe owner of the house and addresses }\n{\nName of\n\t\t\tthe owner of the house and addresses\n}\nNo_____________\nDated _________19\nExecutive Officer/Secretary\n___________Committee__________\nEngineer,\nCommittee,\nForm 'D'\nForm 'D'\n( See Bye-law 11 )\nMunicipal Committee.............\n(To be submitted in duplicate)\nDrainage of Premises\nForm For Licensed Plumber's Completion Certificate\nForm For Licensed Plumber's Completion Certificate\nSignature of Licensed Plumber\nName and address__________\n__________________________\nCommittee's Report\nDate________________\nThe Committee\nTable 1\nTable 1\nOffice Building\n(See Bye-law 26)\nFor accommodation other than for Principals\nSr.No.\nSr.No.\nFitments\nFitments\nFor Male Personnel\nFor Male Personnel\nFor Female Personnel\nFor Female Personnel\n1\n2\n3\n4\n1.\nWater Closets\nfor every 25 persons or part thereof\n1 for every 15 persons or part thereof\n2.\nAblution taps\n1 in each water closet\n1 in each water closet, 1 water tap with draining\n\t\t\t\tarrangements shall be provided for every 50 persons or part\n\t\t\t\tthereof in the vicinity of water closets and urinals\n3.\nUrinals\nNil, upto 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons From\n\t\t\t\t101 to 200 persons add at the rate of 3 per cent; For over 200\n\t\t\t\tpersons add at the rate of 2.5 per cent\n4.\nWash basins\n1 for every 25 persons or part thereof\n5.\nDrinking water fountains\n1 for every 100 persons with a minimum of one on each floor\n6.\nBaths\nPreferably 1 on each floor\n7.\nCleaner's sink\n1 per floor, minimum, preferably in or adjacent to sanitary\n\t\t\t\trooms\nTable 2\nTable 2\nFactories\n(See Bye-law 26)\nSr. No.\nSr. No.\nFitments\nFitments\nFor Male Personnel\nFor Male Personnel\nFor Female Personnel\nFor Female Personnel\n1\n2\n3\n4\n1.\nWater closets\n1 for 1-15 persons 2 for 16-35 persons 3 for 36-65\n\t\t\t\tpersons 4 for 66-100 persons\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t78-100 persons\nFrom 100 to 200 persons add at the rate of 3 per cent\nFrom 101 to 200 persons add at the rate of 5 per cent\nFrom over 200 persons add at the rate of 2.5 per cent\nFrom over 200 persons add at the rate of 4 percent\n2.\nAblution taps\n1 in each water closets 1 water tap with draining arrangements\n\t\t\t\tshall be provided for every 50 persons or part thereof in the\n\t\t\t\tvicinity of water closets and urinals\n1 in each water closets 1 water tap with draining arrangements\n\t\t\t\tshall be provided for every 50 persons or part thereof in the\n\t\t\t\tvicinity of water closets and urinals\n3.\nUrinals\nNil, upto 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons\nFrom 101-200 persons, add at the rate of 3 per cent For\n\t\t\t\tover 200 persons, add at the rate of 2.5 per cent\n4.\nWashing taps with drinking & draining arrangements\n1 for every 25 persons or part thereof\n5.\nDrinking water fountains\n1 for every 100 persons with a minimum of one on each floor\n6.\nBath (preferably showers)\nAs required for particular trades or occupations\nNote. - For many trades of a dirty or dangerous character, more extensive provisions are required by law.\nTable 3\nTable 3\n(See Bye-law 26)\n(Sanitation Requirements for Cinema, Theatres and Public Assembly Halls)\nFitments\nFor Male Public\nFor Female Public\nFor Male Staff\nFor Female Staff\nWater Closet\n... 1 per 100 persons up to 400 persons\n2 per 100 persons up to 200 persons\n1 for 1-15 persons\n1 for 1-12 persons\nFor over 400 persons add at the rate of 1 per 250 persons or\n\t\t\t\t\tpart thereof\nFor over 200 persons add at the rate of 1 per 250 persons or\n\t\t\t\t\tpart thereof\n2 for 16-35 persons\n2 for 13-25 persons\nAblution taps\n... 1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 water tap with drainaing arrangements shall be provided for\n\t\t\t\t\tevery 50 persons or part thereof in the vicinity of water\n\t\t\t\t\tclosets and urinals\nUrinals\n... 1 for 50 persons of part\n*Nil up to 6 persons 1 for 7-20 persons 2 for 21-47\n\t\t\t\t\tpersons\nWash Basins\n... 1 for every 200 persons or part thereof\n1 for 200 persons or part thereof\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\n*Note. - It may be assumed that two-third of the number are males and one-third females.\nTable 4\nTable 4\n(See Bye-law 26)\nArt Galleries, Libraries and Museums\nSr. No.\nFitments\nFor Male Public\nFor Female Public\nFor Male Staff\nFor Female Staff\n1\n2\n3\n4\n5\n6\n1.\nWater Closets\n... 1 per 200 persons up to 400 persons. For over 400\n\t\t\t\t\tpersons, add at the rate of 1 per 250 persons or thereof\n1 per 100 persons up to 200 persons. For over 200 persons add\n\t\t\t\t\tat the rate of 1 per 150 persons or thereof\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\n2.\nAblution taps\n... 1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 water tap with draining arrangements shall be provided for\n\t\t\t\t\tevery 50 persons or part thereof in the vicinity of water\n\t\t\t\t\tclosets and urinals\n3.\nUrinals\n... 1 per 50 persons\n...\n*Nil up to 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\t\tpersons\n...\n4.\nWash basins\n... 1 for every 200 person or part thereof. For over 400\n\t\t\t\t\tpersons, add at the rate of 1 per 250 persons or part thereof\n1 for every 200 persons or part thereof. For over 200 persons\n\t\t\t\t\tadd at the rate of 1 per 150 persons or part thereof\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\n5.\nCleaner's sink\n-------------------- 1 per floor, Minimum\n\t\t\t\t\t----------------------\nNote. - It may be assumed that two-third of the number are males and one-third females.\nTable 5\nTable 5\n(See Bye-law 26)\nSanitation Requirements for Hospitals\n(Indoor Patient Ward)\nFor Males and Females\nWater Closet\nA minimum of 2 (1 European type and 1 Indian type) for every\n\t\t\t\t16 No. of beds or part thereof.\nAblution tap\n1 in each W.C. plus one water tap with draining arrangements\n\t\t\t\tin the vicinity of W.C's and Urinals for every 50 persons or part\n\t\t\t\tthereof.\nWash Basins\n2 upto 30 beds, add 1 for every additional 30 beds or part\n\t\t\t\tthereof.\nBaths\n1 bath with shower for every 8 No. of beds or part thereof.\nBed Pan Washing Sinks\n1 for each ward\nCleaner's Sink\n1 for each ward\nKitchen Sinks and dishwasher (where kitchen is provided)\n... 1 for each ward).\n(Outdoor Patient Ward)\nMale\nFemale\nWater Closet\n1 for every 100 persons or part thereof\n2 for every 100 persons or part thereof\nAblution tap\n1 in each W.C.\n1 in each W.C.\nIn the vicinity of W.C.'s and Urinals one water tap with\n\t\t\tdraining arrangements shall be provided for every 50 persons or\n\t\t\tpart thereof.\nUrinals\n1 for every 50 persons or part thereof\n...\nWash Basins\n1 for every 100 persons or part thereof\n1 for every 100 persons or part thereof.\nTable 6\nTable 6\nSanitation Requirements or Hospitals\n(See Bye-law 26)\n(Administrative Buildings Medical Staff Quarters Nurses Home)\nFitments\nFor Administrative\nFor Male Staff\nFor Femlae Staff\n______________________________________\n____________________________________\nFor Male Personnel\nFor Female Personnel\nFor Nurses\nFor Homes\nWater Closets\n1 for every 25 persons or part thereof\n1 for every 15 persons or part thereof\n1 for 4 persons or part thereof\n1 for 4 persons or part thereof\n1 for 4 persons or part thereof\nAblution taps\nOne in each W.C.\nOne in each W.C.\nOne in each W.C.\nOne in each W.C.\nOne in each W.C.\nIn the vicinity of W.C.'s and urinals a water tap with\n\t\t\t\t\tdraining arrangement shall be provided for every 50 persons or\n\t\t\t\t\tpart thereof\nUrinals\nNil, upto 6 persons\n1 for 17 to 20 persons\n2 for 21-45 persons\n3 for 46-70 persons\n4 for 71-100 persons; from 101 to 200 add at the rate of 3%\n\t\t\t\t\tfor over 200 and @ 2½%\nWash basins\n1 for every 25 persons or part thereof\n1 for every 25 persons or part thereof\n1 for 8 persons or part thereof\n1 or 8 persons or part thereof\n1 or 8 persons or part thereof\nBaths with shower\n1 on each floor\n1 on each floor\n1 for every 4 persons or part thereof\n1 for every 4 persons or part thereof\n1 for every 4 persons or part thereof\nNote. - Cleaner's Sink Minimum of 1 per floor shall be provided.\nNote.\nTable 7\nHotels\n(See Bye-law 26)\nSr. No.\nFitments\nFor Residential Public\n\t\t\t\t\tand Staff\nFor Public Rooms\nFor Non-Residential\n\t\t\t\t\tStaff\n_______________________________________________________________________\nFor Males\nFor Females\nFor Male Staff\nFor Female Staff\n1\n2\n3\n4\n5\n6\n7\n1.\nWater Closets\n1 per 8 persons omitting occupants of the room with attached\n\t\t\t\t\twater closets minimum of 2 if both sexes are lodged\n1 per 100 persons upto 400 persons. For over 400 add at the\n\t\t\t\t\trate of 1 per 250 persons or part thereof\n2 per 100 persons upto 200 persons. For over 200 add at the\n\t\t\t\t\trate of 1 per 100 persons or part thereof\n1 for 1-15 persons 2 for 16-35\n\t\t\t\t\tpersons 3 for 36-65 persons 4 for 66-100 persons\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\t\tpersons 4 for 41-47 persons 5 for 58-77 persons 66 for\n\t\t\t\t\t78-100 persons\n2.\nAblution tape\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 water tap with draining arrangements shall be provided for\n\t\t\t\t\tevery 50 persons or part thereof in the vicinity of water\n\t\t\t\t\tclosets and urinals\n3.\nUrinals\n... ...\n1 per 50 persons or part thereof\n...\nNil upto 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\t\tpersons, 3 for 46-70 persons 4 for 71-100 persons\n...\n4.\nWash Basin\n1 per 10 persons omitting the wash basins installed in the\n\t\t\t\t\troom suite\n1 per water closet and urinal provided\n1 per water closet provided\n1 for 1-15 persons 2 for 16-35 persons 3 for 36-65\n\t\t\t\t\tpersons 4 for 66-100 persons\n1 fpr 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t\t78-100 persons\n5.\nBaths\n1 per 10 persons omitting occupants of the room with bath in\n\t\t\t\t\tsuite\n...\n...\n...\n...\n6.\nSlop sinks\n1 per 30 bed rooms 1 per floor, minimum\n...\n...\n...\n...\n7.\nKitchen sinks and dish washers\n-------in each kitchen ------\nNote. - It may be assumed that two-thirds of the number are males and one third female.\nTable 8\nRestaurants\n(See Bye-law 26)\nSr. No.\nFitments\nFor Male Public\nFor Female Public\nFor Male Staff\nFor Female Staff\n1\n2\n3\n4\n5\n6\n1.\nWater Closets\n1 for 50 seats upto 200 seats. For over 200 seats, add at the\n\t\t\t\t\trate of 1 per 100 seats or part thereof\n1 for 50 seats upto 200 seats. For over 200 seats, add at the\n\t\t\t\t\trate of 1 per 100 seats or part thereof\n1 for 1-15 persons 2 for 16-35 persons 3 for 36-65\n\t\t\t\t\tpersons 4 for 66-100 persons\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t\t78-100 persons\n2.\nAblution taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water close\n1 water tap with draining arrangement shall be provided for\n\t\t\t\t\tevery 50 persons or part thereof in the vicinity of water\n\t\t\t\t\tclosets and urinals\n3.\nUrinals\n1 per 50 seats\nNil, upto 5 persons\n1 for 7-20 persons\n2 for 21-45 persons\n3 for 46-70 persons\n4 for 71-100 persons\n4.\nWash basins\n1 for every water closet provided\n5.\nKitchens sinks and dishwashers\n1 in each kitchen\n7.\nSlop or service sinks\n1 in the restaurant\nNote. - It may be assumed that two-third of the number are males and one-third females.\nTable 9\n(See Bye-law 26)\nSanitation requirement for Schools\nSanitation\nFitments\nNursery School\nSchools other than\n\t\t\t\t\tNursery Schools\nBoarding Schools\n______________________________________________________________________________\nFor Boys\nFor Girls\nFor Boys\nFor Girls\nW.Cs, (Water Closets)\n1 per 15 pupils or part thereof\n1 per 40 pupils or part thereof\n1 per 25 pupils or part thereof\n1 for every 8 pupils or part thereof\n1 for 6 pupils or part thereof\nAblution tapes\n1 in each W.C.\n1 in each W.C.\n1 in each W.C.\n1 in each W.C.\n1 in each W.C.\nIn the vicinity of W.Cs. and urinals a water tap with\n\t\t\t\t\tdraining arrangements shall be provided for every 50 pupils or\n\t\t\t\t\tpart thereof.\nWash Basins\n1 per 15 pupils or part theroef\n1 per 45 pupils or part thereof\n1 per 40 pupils or part thereof\n1 for 8 pupils or part thereof\n1 for every 6 pupils or part thereof\nUrinals\n1 per 20 pupils or part thereof\n1 for every 25 pupils or part thereof\nBaths\n1 bath-sink per 40 pupils\n1 for every 8 pupils or part thereof\n1 for every 6 pupils or part thereof\nDrinking water fountains\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\nNote. - Cleaner's sink at least 1 per floor shall be provided.\nTable 10\nSchools\n(See Bye-law 26)\nSr. No.\nFitments\nNursery Schools\nSchools other than\n\t\t\t\t\tNursery Schools\nBoarding Schools\n__________________________________________________________________________\nFor Boys\nFor Girls\nFor Boys\nFor Girls\n1\n2\n3\n4\n5\n6\n7\n1.\nWater-closet\n1 per 15 pupils or part thereof\n1 per 40 pupils or part thereof\n1 per 25 pupils or part thereof\n1 for every 8 pupils or part thereof\n1 for every 6 pupils or part thereof\n2.\nAblution taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 water tap with draining arrangements shall be provided for\n\t\t\t\t\tevery 50 pupils or part thereof in the vicinity of water-closets\n\t\t\t\t\tand urinals\n3.\nUrinals\n...\n1 per 25 pupils or part thereof\n...\n1 for every 25 pupils or part thereof\n...\n4.\nWash basin\n1 per 15 pupils or part thereof\n1 per 40 pupils or part thereof\n1 per 40 pupils or part thereof\n1 for every 8 pupils or part thereof\n1 for every 6 pupils or part therof\n5.\nBaths\n1 bath-sinks per 40 or part thereof\n...\n...\n1 for every 8 pupils or part thereof\n1 for every 6 pupils or part thereof\n6.\nDrinking water fountains\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\n1 for every 50 pupils or part thereof\n7.\nCleaner's sinks\n1 per floor, Minimum\nNote. - For teaching staff, the schedule of fitments to be provided shall be the same as in the case of office buildings (See Table 1).\nTable 11\nHostels\n(See Bye-law : 26)\nSr. No.\nFitments\nFor Resident and\n\t\t\t\t\tResidential Staff\nFor Non- Residential\n\t\t\t\t\tStaff\nRooms wherein\n\t\t\t\t\tOutsiders are received\n_____________________________________________________________________________________________________________\nFor Males\nFor Females\nFor Males\nFor Females\nFor Males\nFor Females\n1.\nWater Closets\n1 for every 8 persons or part thereof\n1 for every 6 persons or part thereof\n1 for 1-15 persons 2 for 16-35 persons 3 for 36-65\n\t\t\t\t\tpersons 4 for 66-100 persons\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t\t78-100 persons\n1 per 100 persons upto 400 persons For over 400 persons add\n\t\t\t\t\tat the rate of 1 for 250 persons or part or part thereof\n2 per 100 persons upto 200 persons For over 200 persons add\n\t\t\t\t\tat the rate of 1 for 100 persons or part thereof\n2.\nAblution taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n3.\nUrinals\n1 for 25 persons or part thereof\n...\nNil, upto 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons'\n...\n1 per 50 persons or part thereof\n...\n4.\nWash basins\n1 for 8 persons or part thereof\n1 for 6 persons or part thereof\n1 for 1-15 persons 2 for 16-35 persons 3 for 36-65\n\t\t\t\t\tpersons 4 for 66-100 persons\n1 for 8-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t\t78-100\n1 per each water closet and urinal provided\n1 per each water closet provided\n5.\nBaths\n1 for 8 persons or part thereof\n1 for 6 persons or part thereof\n...\n...\n...\n...\n6.\nCleaner's sinks\n...\n1 per floor, Minimum\nAppendix\nAppendix\n(See Bye-law 79)\n(i) For Class I committee\nRs. 75\n(ii) For Class II committee\nRs. 45\n(iii) For Class III committee\nRs. 25\n(ii) Every such licence shall be in form L. 3 enclosed and shall be granted subject to the conditions printed on the reverse of the form.\n(iii) A licence may, at any time, after due notice has been given to the licensee, be cancelled for a breach of any condition on which it was granted. In the event of such cancellation the licensee shall not be entitled to any refund of any portion of licence fee.\n(iv) The licence shall not be transferable. On the licensee ceasing to work as a licensed plumber for any reason other than that his licence has been cancelled for a breach of the condition of the licence, he shall surrender his licence for cancellation and the committee shall refund to the licensee such portion of the licence fee as to cover the unexpired portion of the licence.\n(v) No licence shall shall be re-issued or endorsed for continuance when its term has expired. On the expiry of the period for which the licence was granted the licensee shall, if he still requires a licence surrender his old licence within 30 days of its expiry and apply for a new licence.\nFor Class I committee\nRs. 50\nFor Class II committee\nRs. 20\nFor Class III committee\nRs. 10\n(a) The plumber in all matters in which he may be employed, shall afford every assistance in his power to the committee and their officers in carrying out and enforcing the rules and orders for the time being in force.\n(b) The plumber shall in every work in which he may be employed as far as his employment extends, comply with the provisions of this appendix and such orders may be issued by the committee.\nForm E\nForm E\nApplication for Grant of Plumber's Licence\nApplication for Grant of Plumber's Licence\n(1) Licence fee for the period from ________________ to _____________\n(2) Security deposit Rupees 400\nDate _____________\nYours faithfully,\nForm No. L. 3\nForm No. L. 3\nPAGE\nBook\n\t\t\tNo. 1\nBook\n\t\t\tNo. 1 Not Transferrable\nCOUNTERFOIL FOR LICENCE\nNo. _______________ LICENCE\n___________ Committee ____\nMunicipal Committee _______________\nDated ___________ 19\nName of Licensee_________\nWhereas __________________________\nFather's Name ___________\nhas paid to the_______ Committee Rs.____\nAddress ________________\nhe is permitted to ___________________\nCaste __________________\nwithin the Committee of ______________\nTrade _________________\nfrom 1st ______________ to __________\nDESCRIPTION OF LICENSEE\nPurpose of Licence ________\n_________________________\nDate of Licence __________\nName Father's Name Caste Trade Address Remarks\nPeriod of Licence ________\nAmount paid ____________\n____________________\nSignature of Licensing Officer\nRs. Ps. _______________________ Signature of Licensing Officer Note. This licence is subject to the conditions prescribed in the appendix for the grant of licences to Plumbers. The conditions are given in brief on the reverse. [See Below] Conditions [in respect of Licence in Form L 3 ] (1) This licence may, at any time after due notice has been given to the licence be cancelled for breach of any condition on which it was granted. In the event of such cancellation the licensee shall not be entitled to any refund of any portion of the licence fee. (2) This licence is not transferrable. On the licensee ceasing to work as licensed plumber for any reason, other than that his licence has been cancelled for a breach of the condition of the licence, he shall surrender this licence for cancellation and the Committee shall refund such portion of licence fee as may be deemed to cover the un-expired period of the licence. (3) On the expiry of the period for which this licence was granted the licensee shall if he still requires a licence surrender the licence and apply for a new licence.\n_______________________ Signature of Licensing Officer Note. This licence is subject to the conditions prescribed in the appendix for the grant of licences to Plumbers. The conditions are given in brief on the reverse. [See Below] Conditions [in respect of Licence in Form L 3 ] (1) This licence may, at any time after due notice has been given to the licence be cancelled for breach of any condition on which it was granted. In the event of such cancellation the licensee shall not be entitled to any refund of any portion of the licence fee. (2) This licence is not transferrable. On the licensee ceasing to work as licensed plumber for any reason, other than that his licence has been cancelled for a breach of the condition of the licence, he shall surrender this licence for cancellation and the Committee shall refund such portion of licence fee as may be deemed to cover the un-expired period of the licence.\nNote. This licence is subject to the conditions prescribed in the appendix for the grant of licences to Plumbers. The conditions are given in brief on the reverse. [See Below] Conditions [in respect of Licence in Form L 3 ] (1) This licence may, at any time after due notice has been given to the licence be cancelled for breach of any condition on which it was granted. In the event of such cancellation the licensee shall not be entitled to any refund of any portion of the licence fee.\nNote. This licence is subject to the conditions prescribed in the appendix for the grant of licences to Plumbers. The conditions are given in brief on the reverse. [See Below]\nConditions\nConditions\n[in respect of Licence in Form L 3 ]\nSchedule I\n(See bye-law 79)\nQualification of Plumber\n(1) Qualification approved by the Institute of Engineers for its associate membership.\n(2) Diploma in Civil Engineering from any College or Institution recognised by Government of Haryana, with atleast 3 years experience in Sanitary Engineering works.\n(3) Plumber of atleast 5 years practical experience and who has passed the test conducted by the P.W.D. Public Health Branch, Haryana.\nSchedule II\n(See bye-law 24)\nEstimation of Maximum Flow of Waste Water\n2000\n1750\n1500\n1250\n1000\n750\n500\n250\n0\n500\n1000\n1500\n2000\n2500\n3000\nFixture Units\nIa Estimate Curves\n500\n400\n300\n200\n100\n0\n20\n60\n80\n120\n160\n200\n240\nFixture Units\n______ System Predominantly For Flush Volres ----------- System Predominantly For Flush Tanks 1B Enlarged Scale Curves Fig 1 Peak Flow Load Curves\nTable 1\nTable 1\nFixture Units for Different Sanitary Appliances of Group\nSr. No.\nSr. No.\nType of Fixture\nType of Fixture\nFixture Unit value as Load Factors\nFixture Unit value as Load Factors\n1\n1\n2\n2\n3\n3\n1.\nOne bathroom group consisting of water closet, wash basin and\n\t\t\t\t\tbath tub or shower stall :\n(a) Tank water-closet\n6\n(b) Flush-value water-closet\n8\n2.\nBath tub*\n3\n3.\nBidet\n3\n4.\nCombination sink and tray (drain board)\n3\n5.\nDrinking fountain\n½\n6.\nPloor traps**\n1\n7.\nKitchen sink, domestic\n2\n8.\nWash basin, ordinary***\n1\n9.\nWash basin, surgeon's\n2\n10.\nShower stall, domestic\n2\n11.\nShowers (group) per head\n3\n12.\nUrinal, wall lip\n4\n13.\nUrinal, stall\n4\n14.\nWater closet, tank-operated\n4\n15.\nWater-closet, value-operated\n8\n*A Shower head over a bath tub does not increase the fixture unit value.\n**Size of Floor trap shall be determined by the area of surface water to be drained.\n***Wash basin with 32 mm and 40 mm trap have the same load value.\nTable II\nTable II\nFixture Unit Values for Fixtures Based on Fixture Drain or Trap Size\nSr. No.\nSr. No.\nFixture Drain on Trap size\nFixture Drain on Trap size\nFixture Unit value\nFixture Unit value\n1\n1\n2\n2\n3\n3\n1.\n30 mm and smaller\n1\n2.\n40 mm\n2\n3.\n50 mm\n3\n4.\n65 mm\n4\n5.\n75 mm\n5\n6.\n100 mm.\n6\nTable III\nTable III\nMaximum Number or Fixture Units that can be Connected to Branches and Stacks\nMaximum Number of Fixutre Units* that can be\n\t\t\t\tconnected\nMaximum Number of Fixutre Units* that can be\n\t\t\t\tconnected\nSr. No.\nSr. No.\nDiameter of Pipe\nDiameter of Pipe\nAny Horizontal Fixture Branch\nAny Horizontal Fixture Branch\nOne Stack of 3 Storeys in Height or 3\n\t\t\t\tIntervals\nOne Stack of 3 Storeys in Height or 3\n\t\t\t\tIntervals\nMore than 3 Storeys in Height\nMore than 3 Storeys in Height\nTotal for stack\nTotal for stack\nTotal at one storey or branch interval\nTotal at one storey or branch interval\n1\n1\n2\n2\n3\n3\n4\n4\n5\n5\n6\n6\nmm\n1.\n30\n1\n2\n2\n1\n2.\n40\n3\n4\n8\n2\n3.\n50\n6\n10\n24\n6\n4.\n65\n12\n20\n42\n9\n5.\n75\n20\n30\n60\n16\n6.\n100\n160\n240\n500\n90\n7.\n125\n360\n540\n1,100\n200\n8.\n150\n620\n960\n1,900\n350\n9.\n200\n1,400\n2,200\n3,600\n600\n10.\n250\n2,500\n3,800\n5,600\n1,000\n11.\n300\n3,900\n6,000\n8,400\n1,500\n12.\n375\n7,000\n..\n..\n..\n*Depending upon the probability of simultaneous use of appliances considering the frequency of use and peak discharge rate.\nTable IV\nTable IV\nMaximum Number of Fixture Units that can be Connected to Building Drains & Sewers\nSr. No.\nSr. No.\nDiameter of Pipe\nDiameter of Pipe\nMaximum number of Fixture Units that can be\n\t\t\t\tconnected to any portion* of the Building Drains or the Building\n\t\t\t\tSewer\nMaximum number of Fixture Units that can be\n\t\t\t\tconnected to any portion* of the Building Drains or the Building\n\t\t\t\tSewer\nFor Gradients\nFor Gradients\n1/200\n1/200\n1/100\n1/100\n1/50\n1/50\n1/25\n1/25\n1\n1\n2\n2\n3\n3\n4\n4\n5\n5\n6\n6\n7\n7\nmm\n1.\n100\n...\n...\n180\n216\n250\n2.\n150\n...\n700\n840\n1,000\n3.\n200\n...\n1,400\n1,600\n1,920\n2,300\n4.\n250\n...\n2,500\n2,900\n3,300\n4,200\n5.\n300\n...\n3,900\n4,600\n5,600\n6,700\n6.\n375\n...\n7,000\n8,300\n10,000\n12,000\n*includes branches of the building sewer.",
"footnote": "",
"is_definition": false,
"sort_order": 80
}
],