Other essential infrastructure requirements for ICD and CFS - (f)
High Masts. Adequate numbers of 30 meters high mast lighting towers with LED flood lights should be installed. The LED should have a minimum lumen level of 20 lux on the ground up to 50 meters from the center of the high mast. The beam angle of luminaries/ lamps positioning must be suitable to cover illumination on the ground as well as stored containers in the yard up to 16 meters high.
{
"act_title": "BIHAR LOGISTICS POLICY 2023",
"act_slug": "bihar-logistics-policy-2023",
"section_label": "Section",
"section": {
"number": "73",
"title": "Other essential infrastructure requirements for ICD and CFS - (f)",
"chapter": null,
"content": "High Masts. Adequate numbers of 30 meters high mast lighting towers with LED flood lights should be installed. The LED should have a minimum lumen level of 20 lux on the ground up to 50 meters from the center of the high mast. The beam angle of luminaries/ lamps positioning must be suitable to cover illumination on the ground as well as stored containers in the yard up to 16 meters high.",
"footnote": "",
"is_definition": false,
"sort_order": 720
},
"prev_section": "72",
"next_section": "74"
}