61. Exemptions.

(a) The operation of repairing a water-sealed gas-holder by the electric welding process, subject to the following conditions:-
(i) The gas-holder shall contain only the following gases, separately or mixed at a pressure greater than atmospheric pressure, namely, town gas, cokeoven gas, producer gas, blast furnace gas, or gases, other than air, used in their manufacture:
(ii) Welding shall only be done by the electric welding process and shall be carried out by experienced operative under the constant supervision of a competent person.
(b) The operations of cutting or welding steel or wrought iron gas mains and services by the application of heat, subject to the following conditions:-
(i) The main or services shall be situated in the open air, and it shall contain only the following gases, separately or mixed at a pressure greater than atmospheric pressure, namely, gas, coke-oven gas, producer gas, blast furnace gas or gases other than air, used in their manufacture;
(ii) The main or service shall not contain acetylene or any gas or mixture of gases to which acetylene has been added intentionally;
(iii) The operation shall be carried out by an experienced person or persons and at least two persons (including those carrying out the operations) experienced in work on gas mains and over 18 years of age shall be present during the operation;
(iv) The site of the operation shall be free from any inflammable or explosive gas or vapour;
(v) Where acetylene gas is used as a source of heat in connection with an operation, it shall be compressed and contained in a porous substance in a cylinder; and
(vi) Prior to the application of any flame to the gas main or service this shall be pierced or drilled and the escaping gas ignited.
(c) The operation of repairing an oil tank on any ship of the electric weldings process shall be subject to the following conditions:-
(i) The only oil contained in the tank shall have a flash point of not less than 150° F (close test) and a certificate to this effect shall be obtained from a competent analyst;
(ii) The analyst's certificate shall be kept available for inspection by an Inspector, or by any person employed or working on the ship;
(iii) The welding operation shall be carried out only on the exterior surface of the tank at a place (a) which is free from oil or oil leakage in inflammable quantities and (b) which is not less than one foot below the nearest part of the surface of the oil within the tank; and
(iv) Welding shall be done only by the electric welding and shall be carried out by experienced operatives under the constant supervision of a competent person.
General
General
[62.
(b) All industrial processes involving serious fire hazard should be located in building or work place separated from one another by walls of fire resistant construction.
(c) Equipment and plant involving serious fire or flash fire hazard shall, wherever possible, be so constructed and installed that in case of fire, they can be easily isolated.
(d) Ventilation ducts, pneumatic conveyors and similar equipment, involving a serious fire risk should be provided with flame arresting or automatic fire extinguishing appliances.
(e) In all work places having serious fire or flash-fire hazards, passages between machines, installations or piles of material should be at least 90 cm.]
Fire Prevention
Fire Prevention
(b) storage tanks containing oils, paints or other flammable liquids;
(c) grain elevators; and
(d) buildings, tall chimneys or stacks where flammable gases, fumes, dust or lint are likely to be present.
(a) all electrical apparatus shall either be excluded from the area of risk or they shall be of such construction and so installed and maintained as to prevent the danger or their being a source of ignition;
(b) effective measures shall be adopted for prevention of accumulation of static charges to a dangerous extent;
(c) Workers shall wear shoes without iron or steel nails or any other exposed.
(d) smoking, lighting or carrying of matches, lighters or smoking materials, ferrous materials which is likely to cause sparks by friction;
(e) transmission belts with iron fasteners shall not be used; and
(f) all other precautions, as are reasonably practicable shall be taken to prevent initiation of ignition from all other possible sources such as open flames, frictional sparks, overheated surfaces of machinery or plants, chemical or physical chemical reaction and radiant heat.
(b) Flammable liquids shall be stored in closed containers and in limited quantities in well ventilated of fire resistant construction which are isolated from the remainder or the building by fire walls and self closing arc doors.
(c) Large quantities of such liquids shall be stored in isolated adequately ventilated building or fire resisting construction or in storage tanks, preferably under-ground and at a distance from any building as required in the Petroleum Rules, 1976.
(d) Effective steps shall be taken to prevent leakage of such liquids into basements, sumps or drains and to confine any capacing liquids within safe limits.
(b) No waste material of a flammable nature shall be permitted to accumulate on the floors and shall be removed at least once in a day or shift, any more often when possible. Such materials shall be placed in suitable metal containers with covers wherever possible.
Emergent Fire Exits
Emergent Fire Exits
(i) "horizontal exit" means an arrangement which allows alternative egress from a floor area to another floor at or near the same level in an adjoining part of the same building with adequate separation; and
(ii) "travel distance" means the distance an occupant has to travel to reach an exit.
(b) An exit may be door-way, corridor, passageway to an internal or external stairway or to a verandah. An exit may also include a horizontal exit leading to an adjoining building at the same level.
(c) Lifts, escalators and revolving-doors shall not be considered as exits for the purpose of this sub-rule.
(d) In every room of a factory exits sufficient to permit safe escape of the occupants in case of 'lire or other emergency shall be provided which shall be free of any obstruction.
(e) The exits shall be clearly visible and suitably illuminated with suitable arrangement, whatever artificial lighting is to be adopted for this purpose to maintain the required illumination in case of failure of the normal source of electric supply.
(f) The exits shall be marked in a language understood by the majority of the workers.
(g) Fire resisting doors or roller shutters shall be provided at appropriate places 3ong the escape routes to prevent spread of fire and smoKe particularly at the entrance of lifts or stairs were funnel of flue effect may be created inducing an upward spread of fire.
(h) All exists shall provide continuous means of egress to the exterior of a building or to an exterior open space leading to a street.
(i) Exits shall be so located that the travel distance on the floor shall not exceed 30 meters.
(j) In case of these factories where high hazard materials are stored or used, the travel distance to the exit shall rot exceed 22.5 meters and there shall be at least two ways of escape from every room, however, small except toilet rooms, so located that the points of access thereto are out of or suitable shielded from area of high hazard.
(k) Wherever more than one exit is. required for any room space or floor exits shall be placed as remote from each other as possible and shall be arranged to provide direct access in separate directions from any point in the area served.
(l) The unit of exit width used to measure capacity of any exit shall be 50 cm. A clear width of 25 cm. shall be counted as an additional half unit. Clear width of less than 25 cm. shall not be counted for exit width.
(m) Occupants per unit width shall be 50cm. for stairs and 75cm. for doors.
(n) For determining the exits required the occupant load shall be reckoned on the basis of actual number of occupants within any floor area or 10 square meters per person, whichever in more.
(o) There shall not be less than two exits serving every floor area above and below the ground floor, and at least one of them shall be an internal enclosed stairway.
(p) For every building or structure used for storage only, and every section thereof considered separately, shall have access to at least one exit so arranged and located as to provide a suitable means of escape for any person employed therein, and in any such room wherein more than 10 persons may be normally present at least two separate means of exit shall be available, as remote from each other as practicable.
(q) Every storage area shall have access to at least one means of exit which can be readily opened.
(r) Every exit doorway shall open into an enclosed stairway, a horizontal exist, on a corridor or passageway providing continuous and protected means of egress.
(s) No exit doorway shall be less than 100 cm. in width. Doorways shall be not less than 200 cm. in height.
(t) Exit doorways shall open outwards, that is, away from the room but shall not obstruct the travel long any exist. No door when opened, shall reduce the required width of stairway or landing to less than 90 cm. over head or sliding doors shall not be installed for this purpose.
(u) An exit door shall not open immediately upon a flight of stairs. A landing equal to at least the width of the doorway shall be provided in the stairway at each doorway. The level of landing shall be the same as that of the floor which it serves.
(v) The exit doorways shall be openable from the side which they serve without the use of a key.
(w) Exit corridors and passageways shall-be of a width not less than the aggregate required width of exit doorways leading from there in the direction of travel to the exterior.
(x) Where stairways discharge through corridors and passageways the height of the corridors and passageways shall not be less than 2.4 meters.
(y) Internal stairs shall be constructed of non-combustible materials throughout.
(z) Internal stairs shall be constructed as a self contained with at least one side adjacent to an external wall and shall be completely enclosed.
(aa) A stair case shall not be arranged round a lift shaft unless the latter is totally enclosed by a material having a fire resistance rating not lower than that of the type of construction of the former.
(ab) Hollow combustible construction shall not be permitted.
(ac) The minimum width of an internal stair case shall be 100 cm.
(ad) The minimum width of treads without nosing shall be 25 cm. for an internal staircase. The treads shall be constructed and maintained in a manner to prevent slipping.
(ae) The maximum height of a riser shall be 19 cm. and the number of risers shall be limited to 12 per flight.
(af) Hand rails shall be provided with a minimum height of 100 cm. and shall . be firmly supported.
(ag) The use of spiral stair case shall be limited to low occupant lead and to a building of height of 9 meters, unless they are connected to platforms such as balconies and terraces to allow escapes to pause. A spiral staircase shall be not less than 300 cm. diameter and have adequate head room.
(ah) The width of a horizontal exit shall be same as for the exit doorway.
(ai) The horizontal exit shall be equipped with at least one fire door of self closing type.
(aj) The floor area on the opposite or refuge side of a horizontal exit shall be sufficient to accommodate occupants of the floor area served, allowing not less than 0.3 square meter per person. The refuge area shall be provided with exits adequate to meet the requirements of this sub-rule. At least one of the exits shall lead directly to the exterior or street.
(ak) Where there is difference in level between connected areas for horizontal exit, ramps not more than 1 in 8 slope shall be provided. For this purpose steps shall not be used.
(al) Doors in horizontal exits shall be operable at all times.
(am) Ramps with a slope of not more than 1 in 10 may be substituted for the requirements of staircase. For all slopes exceeding 1 in 10 and wherever the use is such as to involve danger of slipping the ramp shall be surfaced with non-slipping material.
(an) In any building not provided with automatic fire alarm a manual fire alarm system shall be provided if the total capacity of the building is over 500 persons, or if more than 25 persons are employed above or below the ground floor, except that no manual fire alarm shall be required in one-storey buildings where the entire area is undivided and all parts thereof are clearly visible to all occupants.
Fire Fighting
Fire Fighting
(a) "Class A fire". -(a) Fire due to combustible materials such as wood, textiles, paper, rubbish and the like-
(i) "Light hazard". -Occupancies like offices, assembly halls, canteens, restrooms, ambulance room and the like;
(ii) "Ordinary hazard." -Occupancies like saw mills, careentary shop, small timber yards, book binding shops engineering workshop and the like;
(iii) "Extra Hazard". -Occupancies like large timber yards, godowns, storing fibrous materials, flour mills, cotton mills, jute mills, large wood working factories and like;
(b) Class B fire. -Fire in flammable liquids like oil, petroleum products, solvents grease, paint, etc.
(c) Class C fire. -Fire arising out of gaseous substances.
(d) Class D fire. -Fire from reactive chemicals, active, materials and the like;
(e) Class E fire. -Fire involving electrical equipment and delicate machinery and the like;
(a) Class A fire-
(i) Light hazard. -One 9 litre water bucket for every 100 square metres of floor area or part thereof and 9 litre water type (soda), acid or gas pressure or bucket pump extinguisher shall be provided for each 6 buckets or part thereof with a minimum of the extinguisher and two buckets per compartment of the building. These equipments shall be as distributed over the entire that a person have to travel not more than 25 metres from any point to reach the nearest equipment.
(ii) Ordinary hazard. -One 9 litre water bucket for every 100 square metres of floor area or part thereof and one 9 litre water type (soda), acid gas pressure or bucket pump) extinguisher minimum of 2 extinguisher and 4 buckets per compartment of the building. The equipment shall be so distributed over the entire floor area that a person shall have to travel not more than 15 metre from any point to reach the nearest equipment.
(iii) Extra hazard. -The scale of equipment would be what is prescribed for ordinary hazard and in addition such extra equipment as in the opinion of the Inspector are necessary, having regard to the special nature of occupancy:
(b) Class B fire. -There shall be at least one fire extinguisher either foam type or carbon dioxide or dry powder per 50 square metres of floor area and shall be so distributed that no person is required to travel more than 15 metres from any point to reach the nearest equipment. In addition to the requirement of extinguishers specified here, requirements as laid down in clause (a) shall also be provided..
(c) Class C fire. -Carbon dioxide or dry chemical power extinguishers shall be provided near each plant or group of plants.
(d) Class D fire. -Special dry power (chloride based) type of extinguishers, or sand buckets shall be provided on a scale as laid down for class B fire. The Inspector may require a higher scale of portable equipment to be provided depending upon the risk involved.
(e) Class E fire. -Carbon dioxide or dry power type extinguishers shall be provided near each plant or group of plants depending upon the risk involved.
(i) Serial number;
(ii) Date of last refilling; and
(iii) Date of last inspection.
(b) (i) Each trailer pump shall be provided with equipment as per schedule appended to this rule.
(ii) In addition to the equipments specified in the said schedule each trailer pump shall be provided with adequate breathing apparatus.
(iii) The Chief Inspector may by an order in writing direct the occupier and/or Manager of a factory to provide such additional equipments and breathing apparatus and of such type as he may consider necessary in consideration of the nature and degree of hazards.
(iv) The equipment specified in this sub-rule shall conform to such Indian Standards specification as may be in existence.
(c) Trailer pumps shall be housed in a separate shed or sheds which shall be sited close to a principle source of water supplies in the vicinity of the main risks of the factory.
(d) In factories where the area in such as cannot be reached by menhauling of trailer pumps within reasonable time, vehicles with towing attachment shall be provided at the scale of one for every four trailer pumps with a minimum of one such vehicle kept available at all times.
(e) Water supply shall be provided to give flow of water as required under clause (a) for at least 100 minutes. At lest 50 per cent of this water-supply for, 4,50,000 litres whichever is less, shall be in the form of static tanks of adequate capacities (not less than 4,50,000 litres each) distributed round the factory with due regard to the potential fire risk in the factory (where piped supply is provided, the size of the main shall not be less than 15 centimeters diameter and it shall be supplying a minimum of 4,500 litres per minute at a pressure of not less than 7 kilograms per square centimeter).
(f) All trailer pumps including the equipment provided with them and vehicles for towing them shall be maintained in good condition and subjected to periodical inspection and testing as required.
(b) Sufficient number of persons shall be trained in the proper handing of fire fighting equipments and their use against the types of fire for which they are intended, to ensure that adequate number of persons are available for fire-fighting both by means of first-aid fire-fighting equipment and others. Wherever vehicles with' towing attachment are to be provided as required in clause (d) of sub-rule 22 sufficient number of persons shall be trained in driving, where the need arises, those vehicles to ensure that trained persons are available for driving them.
(c) Fire-fighting drills shall be held at least once in every 3 months, and records in respect of such periodical drills shall be maintained in a bound register and shall be produced for inspection on demand.
Schedule
[See Rules 62 (22) (25) (1)]
Equipment to be provided with Trailer Pump.
Note. -If it appears to the Chief Inspector of Factories that in any factory the provision of breathing apparatus is necessary, he may by order in writing require the occupier to provide suitable breathing apparatus in addition to the equipment for light trailer pump or large trailer pump as the case may be.
Note.
62A.
[62B. Safety Officers.
(i) Possesses a recognised degree in any branch of engineering or technology and has had practical experience of working in a factory in a supervisory capacity for a period of not less than 2 years; or a recognised degree in physics or chemistry and has a practical experience of working in a factory in a supervisory capacity for a period of not less than 6 years or a recognised diploma in any branch of engineering or technology and has had practical experience of working in a factory in a supervisory capacity for a period of not less than 4 years.
(ii) Possesses a degree or diploma in industrial safety recognised by the State Government in this behalf; or has qualified at a written and viva-voca examination conducted by the Chief Inspector:
(b) Notwithstanding the provisions in clause (a) any person who possesses a recognised degree in engineering or technology and has had experience of not less than 2 years, in a department of the Central or State Government which deals with the administration of the Factories Act, 1948, or
(b) The Chief Safety Officer shall be given the status of Departmental Head and shall work directly under the control of the Chief Executive of the factory. All other Safety Officers shall be given appropriate status to enable them to discharge their functions effectively.
(c) The scale of pay and the allowance to be granted to the Safety Officers including the Chief Safety Officer, and the other conditions at their service "shall be the same as those of the other officers of corresponding status in the factory.
(d) In the case of dismissal or discharge, a Safety Officer shall have a right to appeal to the Chief Inspector:
(i) to advise the concerned departments in planning and organising measures necessary for the effective control of personal injuries;
(ii) to advise on safety aspects in all job studies, and to carry out detailed job safety studies on selected jobs;
(iii) to check and evaluate the effectiveness of the action taken or proposed to be taken to prevent personal injuries;
(iv) to advise the purchasing and stores departments in ensuring availability of high quality personal protective equipment;
(v) to render advice on matters relating to carrying out of plant safety inspections;
(vi) to carry out plant safety inspections in order to observe the physical conditions of work and the work practices and procedures followed by workers and to render advice on measures to be adopted for removing the unsafe physical conditions and preventing unsafe actions by workers;
(vii) to render advice on matters related to reporting and investigations of industrial accidents and diseases;
(viii) to investigate accidents, locate causes and render advice on measures to be adopted for removing the causes of accidents. Accident shall include all major or minor injury cases;
(ix) to investigate the cases of industrial diseases contracted and dangerous occurrences reportable under rule 96;
(x) to advise on the maintenance of such records relating to accidents, dangerous occurrences and industrial diseases as are necessary;
(xi) to promote setting up of safety committees according to the provisions of rule 62-A*;
(xii) to organise in association with the concerned departments, awards, campaigns, competitions and other activities which will develop and sustain the interest of the workers in establishing and maintaining safe conditions of work and procedures; and
(xiii) to design and conduct either independently or in collaboration with the training departments, suitable training and educational programme related to and required for the prevention of personal injuries.
(a) For all factories wherein 1,000 or more workers are ordinarily employed-
(i) Where the number of workers ordinarily employed in a factory is not less than 1,000 and not more than 1,500-one Safety Officer;
(ii) Where the number of workers ordinarily employed in a factory is more than 1,500, but does not exceed 10,000-One additional Safety Officer for every 1,500 workers in excess of 1,500:
(iii) Where the number of workers ordinarily employed exceeds 10,000-One Safety Officer for every 2,000 workers above 10,000:
(b) For all factories wherein manufacturing processes or operations declared to be dangerous under Section 87 of Factories Act, 1948, by Rule 95 of Bihar Factories Rules, 1950 are carried on:-
(i) Where the number of workers ordinarily employed in a factory is more than 500-One Safety Officer;
(ii) Where the number of workers ordinarily employed in a factory is more than 1,000 the number of Safety Officers to be employed shall be as specified in sub-rule 5(a).
(c) For all Factories wherein apart from normal manufacturing operations construction, demolition, modification or similar work are carried on and where in more than 500 workers are ordinarily employed for such work one additional Safety Officer shall be employed. If the number of workers ordinarily employed in such jobs exceeds 1,000, Additional Safety Officer shall be employed in accordance with the provision of sub-rule 5(a).
[62C. Safety Committee.
(a) Wherein 250 or more workers are ordinarily employed; or
(b) Which carries on any process or operation declared to be dangerous under Section 87 of the Act; or
(c) Which carries on 'hazardous process' as defined under Section 2 (cb) of the Act;]
(a) A senior official, who by his position in the organisation can contribute effectively to the functioning of the committee, shall be the Chairman;
(b) A Safety Officer and a Factory Medical Officer, wherever available and the Safety Officer in such a case shall be the Secretary of the Committee;
(c) A representative each from the production, maintenance and purchase departments.
(a) ask for necessary information concerning health and safety of the workers,
(b) Seek any relevant information concerning health and safety of the workers.
(a) assisting and co-operating with the management in achieving the aims and objectives in the Health and Safety Policy of the occupier;
(b) Dealing with all matters concerning health safety and environment and to arrive at practicable solutions to problems encountered;
(c) creating safety awareness amongst all workers;
(d) undertaking educational, training and promotional activities;
(e) deliberating on reports of safety environmental and occupational health surveys, emergency plans, safety audits, risk assessment and implementation of the recommendations made in the reports;
(f) carrying out health and safety surveys and to identify causes of accidents;
(g) looking into any complaint made on the likelihood of an imminent danger to the safety and health of the workers and suggest corrective measures; and
(h) reviewing the implementation of the recommendations made by it.
[Chapter IV-A]
62-AH. Site Appraisal Committee.
(a) The State Government may constitute a Site Appraisal Committee and reconstitute the committee as and when necessary;
(b) The State Government may appoint a senior official of the Factories Inspectorate, preferably with qualification in Chemical Engineering to be the Secretary of the committee;
(c) The State Government may appoint the following as members of the Committee:-
(i) A representative of the Fire Service Organisation of the State Government;
(ii) A representative of the State Department of Industries:
(iii) A representative of the Director General of Factory Advice Service and Labour Institutes, Bombay.
(a) Applications for appraisal of sites in respect of the factories covered under Section 2 (cb) of the Act shall be submitted to the Chairman of the State Appraisal Committee.
(b) The application for site appraisal alongwith 15 copies thereof shall be submitted in the Form annexed to this Rule. The committee may dispense with furnishing information on any particular item in the Application Form if it considers the same to be not relevant to the application under consecration.
(a) The Secretary shall arrange to register the applications received for appraisal of site in a separate register and acknowledge the same within a period of 7 days.
(b) The Secretary shall fix up meeting in such a manner that all the applications received and registered are referred to the Committee within a period of one month from the date of their receipt.
(c) The Committee may adopt a procedure for its working keeping in view the need for expeditious disposal of applications.
(d) The Committee shall examine the application for appraisal of a site with reference to the prohibitions and restrictions of the location of industry and the carrying on of processes and operations in different areas as per the provisions of Rule 5 of the Environment (Protection) Rules, 1986 framed under the Environment Protection Act, 1986.
(e) The Committee may call for documents, examine experts, inspect the site if necessary and take other steps for formulating its view in regard to the suitability of the site.
(f) Wherever the proposed site requires a clearance by the Ministry of Industry or the Ministry of Environment and Forests, the application for Site Appraisal will be considered by the Site Appraisal Committee only after such clearance has been received.