← Back to Directory
Assam Brick Kilns Establishment and Regulation Rules, 2013
Assam Brick Kilns Establishment and Regulation Rules, 2013
Sections
assam-brick-kilns-establishment-and-regulation-rules-2013.json
•
5 Sections
•
Assam
{
"id": 13568,
"slug": "assam-brick-kilns-establishment-and-regulation-rules-2013",
"title": "Assam Brick Kilns Establishment and Regulation Rules, 2013",
"short_title": "Assam Brick Kilns Establishment and Regulation Rules, 2013",
"act_number": "",
"act_year": 2013,
"act_type": "STATE",
"location": "Assam",
"law_status": "unknown",
"enactment_date": null,
"description": "Assam Brick Kilns Establishment and Regulation Rules, 2013",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "2",
"title": "2. Location.",
"chapter": null,
"content": "(i) Brick kiln shall be established atleast 300 meters away from residential area having a minimum population of 100-150 people or 20 houses including both kachcha/thatched and pucca houses, 500 meters from a residential area having a population more than 150 or more than 20 houses including both kachcha/thatched and pucca houses. However, the distance from notified municipal area/town committee shall be not less than 1.0 Km.\n(ii) The aerial distance of brick kilns shall be atleast 500 meters from the areas like registered hospital, school, public building, religious place or a place where flammable substances are stored. Brick kilns shall not be allowed within a radius of 1.0 Km in notified sensitive areas like zoo, wild life sanctuary, historic monuments, museum etc. The distance to be verified by an Officer not below the rank of Forest Range Officer/Revenue Circle Officer or the Board Official not below the rank of Assistant Executive Engineer.\n(iii) Brick kilns shall not be constructed within 200 meters (aerial distance) from the sides of railway tracks.\n(iv) The distance between two brick kilns shall not be less than 500 meters to avoid clustering of brick kilns in an area if a new brick kiln is being installed.\n(v) Brick kilns should be constructed atleast 500 meters away from the path of any natural water flow as well as from river bank, water front of beels, lakes etc. More over no top soil from these areas within the vicinity of 500 meters, be extracted for making the green bricks (kutcha bricks), as the top soil is necessary for ensuing stability of river bank.\nNote. - (i) The distance criteria mentioned under para 2(i) to 2 (v) shall not be applicable for existing brick kilns which have been established with valid Consent of the Board prior to the date of issue of these Rules.\nNote.\n(ii) All distances in the above rules are from the stack of the brick kiln considering stack as the central point of the kiln.\n(vi) No brick kilns shall be allowed within the co-ordinates of \"No Development Zone\" around the Numaligarh Refinery without the Consent of MoEF. The renewal of \"Consent to Operate\" in respect of existing units for their operation at present location would depend upon the final outcome of case pending with National Green Tribunal and decision of MoEF.",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "3",
"title": "3. Restrictions on setting up of Brick Kiln.",
"chapter": null,
"content": "(ii) For establishment of a new brick kiln, public hearing shall be conducted in the concerned Gaon Panchayat for assessing the acceptability of the unit by local people and without \"No Objection\" from Gaon Panchayat no new brick kiln shall be allowed.\n(iii) The clay collection/excavation area for the brick kiln shall not be an area falling within the restriction limits prescribed under Rule 7 of Assam Minor Mineral Concession Rules, 2013. The brick industry must have valid source for raw materials supply. An affidavit to this effect shall be submitted by the project proponent.",
"footnote": "",
"is_definition": false,
"sort_order": 1
},
{
"number": "4",
"title": "4. Operation of Brick Kilns.",
"chapter": null,
"content": "(ii) Stack height of brick kiln and Emission Standard shall be as per notification of Ministry of Environment & Forests, Government of India under Schedule-I at SI. No. 74 of Environment (Protection) Rules, 1986 vide G.S.R. 543(E) date 22.07.2009 (as amended from time to time). The ambient air quality shall conform to the National Ambient Air Quality Standards notified by Ministry of Environment & Forests vide No. G.S.R. 826(E) date 16.11.2009 or as amended from time to time. The brick unit shall install permanent stack and the height of the stack must be atleast 30 meters. Brick Kilns with moving chimney shall not be allowed.\nBrick Kilns with moving chimney shall not be allowed.\n(iii) The brick kiln shall be provided with port hole, platform, ladder etc. for purpose of monitoring and sampling. The port hole shall be made at a height of 2/3rd of the total height of the stack.\n(iv) The emission sample shall be collected when the brick kiln is fully fired and in operation.",
"footnote": "",
"is_definition": false,
"sort_order": 2
},
{
"number": "5",
"title": "5. Other Requirements.",
"chapter": null,
"content": "(ii) The brick unit shall use crushed coal for better burning efficiency.\n(iii) The brick unit shall install and operate adequate pollution control measures such as gravity chamber, water sprayers etc. at strategic locations.\n(iv) The brick unit shall use local agricultural wastes residues as a substitute to coal.\n(v) Fly ash shall be used in brick molding in compliance of the notification (as amended) issued under the provision of Environment (Protection) Act, 1986 to manufacture soilfly ash bricks. The non-hazardous industrial wastes such as stone dust, rice husk, ash, red mud etc. should be encouraged for mixing with soil in brick molding.\n(vi) In the event of closing down of the brick field, the site shall be completely reclaimed before abandoning.",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "6",
"title": "6. Application.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 4
}
],
"metadata": {
"Act ID": "Last Updated 13th February, 2020 [ass344]",
"Act Number": "",
"Enactment Date": "",
"Act Year": "2013",
"Short Title": "Assam Brick Kilns Establishment and Regulation Rules, 2013",
"Type": "STATE",
"Location": "Assam"
},
"updated_at": "2026-09-29 21:55:18"
}