(i) A Services and Utilities Plan as per standards for water supply system, drainage and storm water disposal system, sewerage system, rain water harvesting structures, and for other utilities.
(ii) A landscaping plan including rain water harvesting and waste water recycling details.
(iii) Parking and internal Circulation Plan along with Common pool parking area plan, if any.
Table V
Table V
Height of building block
Height of building block
Distance to be maintained from periphery
building block
Distance to be maintained from periphery
building block
Distance between two blocks
Distance between two blocks
Up to 10 mts.
3 mts.
2 mts.
Above 10 mts & up to 12
mts 4 mts.
3 mts.
Above 12 mts. & below 18
mts. 6 mts.
6 mts.
Above 18 mts.
As per alround set-backs Buildings given in
Table IV
(a) (i) Stilt parking floor permissible is exclusive of height of building below 15 mts. Height of stilt floor shall not exceed 3.0 mts.
(ii) Wherever Cellars are permissible these are excluded from height of Building.
(iii) No Balcony Projection shall be allowed to extend onto the minimum distances to be maintained and other open spaces.
(b) Common amenities and facilities like shopping center, community hall or center/club house etc. are required to be provided which shall be 5% of the total built up area and shall be planned and developed in cases where the units are above 100 in number and not be part of the residential blocks.
(c) A through public access road of 9 m width with 2-lane black-topped is to be developed on any one side at the periphery/as per suitability and feasibility for the convenience of accessibility of other sites and lands located in the interior. This may not be necessary in case where a peripheral road of minimum 9 m width already exists.
(d) In case of blocks up to 12 m height, access through pathways of 6m width branching out from the internal roads /loop road would be allowed. All internal roads and pathways shall be developed as per standards.
(e) Minimum of 10% of site area shall be earmarked for organized open space and be utilized as greenery, tot lot or soft landscaping, etc., and shall be provided over and above the mandatory open spaces. This space may be in one or more pockets and shall be open to sky.
(f) All the roads and open spaces mentioned in various schemes in Rule 10 shall be handed over to the local authority free of cost through a registered gift deed before the issue of Occupancy Certificate. The Society/ Association may in turn enter into an agreement with the local authority for utilizing, managing and maintaining the roads and open spaces. In case of any violation or encroachment, the local authority has the power to summarily demolish the encroachments and resume back the roads and open spaces and keep it under its custody.
Row Type Housing/Row Type Shopping Precincts.
(b) Minimum size of individual plots for row houses 50 sq.m.
Not more than 8 plots shall be developed in a row
Separation between two blocks shall not be less than 6 mt. which may be an open space or an alley/ pedestrian plaza.
Only internal staircase would be allowed.
(c) Minimum width of internal roads: 9m
Internal cul-de-sac road of 6m with max. length 50 mt. is allowed.
(d) Minimum open space : 10% of site area.
(e) Height permissible : 2 floors or 6 m for plots up to 125 sq.m. Ground + 2 floors for plots above 125 sq.m. for row houses
(f) Minimum setbacks: Front 3m ; Rear 1.5 m
The setbacks in a row can be interchangeable, however the aggregate setback shall be minimum 4.5 m.
In case of row type shopping precincts, back to back shops with above front setback of 3 m would be allowed.
(g) In case of very large projects more than 5 acres, common amenities and facilities like shopping center, community hall/club house etc. are required to be provided in 5% of the area.
(h) In case of Row Type Shopping Precincts, common basement parking in one or more levels would be permissible subject to conditions mentioned in Rule (11).
Cluster Housing.
(b) minimum plot size for cluster house; 25sq. m. with maximum number of 20 houses in a cluster.
(c) Minimum size of cluster open space: 36 sq.m with a minimum width of 6m.
(d) Height permissible; 2 floors or 6 m.
(e) Minimum access road to the Cluster Housing Complex; 9 m
(f) Internal access may be through pedestrian pedestrian paths of 6m
(g) Minimum space between two clusters; 6m which may be utilized as pathway/alley.
(h) Building setbacks; No setbacks are needed for interior clusters as the lighting and ventilation is either from the central open space of cluster and the surrounding pedestrian pathway/access road of the cluster. However, interior courtyards may be provided for larger plots and building areas to facilitate lighting and ventilation. For end clusters, the sides that are abutting peripheral thoroughfare roads, the setback shall be as per the Building line given in Table III.
Residential Enclaves.
(b) Residential enclaves would be permitted only in those sites that give through access of minimum 9 m peripheral road for the neigh boring plots or lands that-are located in the interior. They would be governed by good design standards and not impinging on the overall accessibility and circulation network of the area.
(c) Minimum size of site; 4000 sq.m.
(d) Size of plots and height permissible; as per type of housing and requirements as given above for the respective type of housing.
(e) Minimum Common Open space ; 10% of site area.
(f) Building setbacks; As per type of housing and requirements given above for the said type of housing and as per Table III. Semi-detached buildings may also be allowed. The height of such buildings shall not exceed 10 mts. The set-backs shall be as per Table III.
(g) internal Road requirements:
• 9.0 to 18 m for main internal approach roads;
• 9 m for other internal roads and
• 8 m for cul-de-sacs roads between 50-100 m length
• 9 m for looped roads.
Technical approval by Director of Town and Country Planning.
(a)
Municipal Commissioner/Vice Chairman of UDA
-
Member
(b)
Regional Deputy Director of Town Planning
-
Member
(c)
Superintending Engineer, Public Health Dept
-
Member
(d)
A Senior practicing Architect (to be nominated
by DTCP/VC of UDA)
-
Member
(e)
City Planner/Town Planning Officer of local
body/ Planning Officer of UDA
-
Member-Convener
Section 10 • Andhra Pradesh Revised Building Rules, 2008
10. Requirements of Group Development, Group Housing/Cluster Housing/Residential Enclaves and Row Housing Schemes.
andhra-pradesh-revised-building-rules-2008-sec-10.json
•
Section 10
{
"act_title": "Andhra Pradesh Revised Building Rules, 2008",
"act_slug": "andhra-pradesh-revised-building-rules-2008",
"section_label": "Section",
"section": {
"number": "10",
"title": "10. Requirements of Group Development, Group Housing/Cluster Housing/Residential Enclaves and Row Housing Schemes.",
"chapter": null,
"content": "(i) A Services and Utilities Plan as per standards for water supply system, drainage and storm water disposal system, sewerage system, rain water harvesting structures, and for other utilities.\n(ii) A landscaping plan including rain water harvesting and waste water recycling details.\n(iii) Parking and internal Circulation Plan along with Common pool parking area plan, if any.\nTable V\nTable V\nHeight of building block\nHeight of building block\nDistance to be maintained from periphery\n\t\t\t\tbuilding block\nDistance to be maintained from periphery\n\t\t\t\tbuilding block\nDistance between two blocks\nDistance between two blocks\nUp to 10 mts.\n3 mts.\n2 mts.\nAbove 10 mts & up to 12\nmts 4 mts.\n3 mts.\nAbove 12 mts. & below 18\nmts. 6 mts.\n6 mts.\nAbove 18 mts.\nAs per alround set-backs Buildings given in\n\t\t\t\tTable IV\n(a) (i) Stilt parking floor permissible is exclusive of height of building below 15 mts. Height of stilt floor shall not exceed 3.0 mts.\n(ii) Wherever Cellars are permissible these are excluded from height of Building.\n(iii) No Balcony Projection shall be allowed to extend onto the minimum distances to be maintained and other open spaces.\n(b) Common amenities and facilities like shopping center, community hall or center/club house etc. are required to be provided which shall be 5% of the total built up area and shall be planned and developed in cases where the units are above 100 in number and not be part of the residential blocks.\n(c) A through public access road of 9 m width with 2-lane black-topped is to be developed on any one side at the periphery/as per suitability and feasibility for the convenience of accessibility of other sites and lands located in the interior. This may not be necessary in case where a peripheral road of minimum 9 m width already exists.\n(d) In case of blocks up to 12 m height, access through pathways of 6m width branching out from the internal roads /loop road would be allowed. All internal roads and pathways shall be developed as per standards.\n(e) Minimum of 10% of site area shall be earmarked for organized open space and be utilized as greenery, tot lot or soft landscaping, etc., and shall be provided over and above the mandatory open spaces. This space may be in one or more pockets and shall be open to sky.\n(f) All the roads and open spaces mentioned in various schemes in Rule 10 shall be handed over to the local authority free of cost through a registered gift deed before the issue of Occupancy Certificate. The Society/ Association may in turn enter into an agreement with the local authority for utilizing, managing and maintaining the roads and open spaces. In case of any violation or encroachment, the local authority has the power to summarily demolish the encroachments and resume back the roads and open spaces and keep it under its custody.\nRow Type Housing/Row Type Shopping Precincts.\n(b) Minimum size of individual plots for row houses 50 sq.m.\nNot more than 8 plots shall be developed in a row\nSeparation between two blocks shall not be less than 6 mt. which may be an open space or an alley/ pedestrian plaza.\nOnly internal staircase would be allowed.\n(c) Minimum width of internal roads: 9m\nInternal cul-de-sac road of 6m with max. length 50 mt. is allowed.\n(d) Minimum open space : 10% of site area.\n(e) Height permissible : 2 floors or 6 m for plots up to 125 sq.m. Ground + 2 floors for plots above 125 sq.m. for row houses\n(f) Minimum setbacks: Front 3m ; Rear 1.5 m\nThe setbacks in a row can be interchangeable, however the aggregate setback shall be minimum 4.5 m.\nIn case of row type shopping precincts, back to back shops with above front setback of 3 m would be allowed.\n(g) In case of very large projects more than 5 acres, common amenities and facilities like shopping center, community hall/club house etc. are required to be provided in 5% of the area.\n(h) In case of Row Type Shopping Precincts, common basement parking in one or more levels would be permissible subject to conditions mentioned in Rule (11).\nCluster Housing.\n(b) minimum plot size for cluster house; 25sq. m. with maximum number of 20 houses in a cluster.\n(c) Minimum size of cluster open space: 36 sq.m with a minimum width of 6m.\n(d) Height permissible; 2 floors or 6 m.\n(e) Minimum access road to the Cluster Housing Complex; 9 m\n(f) Internal access may be through pedestrian pedestrian paths of 6m\n(g) Minimum space between two clusters; 6m which may be utilized as pathway/alley.\n(h) Building setbacks; No setbacks are needed for interior clusters as the lighting and ventilation is either from the central open space of cluster and the surrounding pedestrian pathway/access road of the cluster. However, interior courtyards may be provided for larger plots and building areas to facilitate lighting and ventilation. For end clusters, the sides that are abutting peripheral thoroughfare roads, the setback shall be as per the Building line given in Table III.\nResidential Enclaves.\n(b) Residential enclaves would be permitted only in those sites that give through access of minimum 9 m peripheral road for the neigh boring plots or lands that-are located in the interior. They would be governed by good design standards and not impinging on the overall accessibility and circulation network of the area.\n(c) Minimum size of site; 4000 sq.m.\n(d) Size of plots and height permissible; as per type of housing and requirements as given above for the respective type of housing.\n(e) Minimum Common Open space ; 10% of site area.\n(f) Building setbacks; As per type of housing and requirements given above for the said type of housing and as per Table III. Semi-detached buildings may also be allowed. The height of such buildings shall not exceed 10 mts. The set-backs shall be as per Table III.\n(g) internal Road requirements:\n• 9.0 to 18 m for main internal approach roads;\n• 9 m for other internal roads and\n• 8 m for cul-de-sacs roads between 50-100 m length\n• 9 m for looped roads.\nTechnical approval by Director of Town and Country Planning.\n(a)\nMunicipal Commissioner/Vice Chairman of UDA\n-\nMember\n(b)\nRegional Deputy Director of Town Planning\n-\nMember\n(c)\nSuperintending Engineer, Public Health Dept\n-\nMember\n(d)\nA Senior practicing Architect (to be nominated\n\t\t\t\tby DTCP/VC of UDA)\n-\nMember\n(e)\nCity Planner/Town Planning Officer of local\n\t\t\t\tbody/ Planning Officer of UDA\n-\nMember-Convener",