(i) The permissible coverage would be as per the minimum setbacks to be left within the given site. The minimum setbacks and permissible height would be as per Table - III given below and shall be permissible subject to the following conditions:
(a) Buildings of height above 15 meters and below 18 meters in Sl. No. 8 of Table - III, shall be permitted only if such plots abut roads of 12 meters minimum width.
(b) Stilt parking floor permissible is exclusive of height of building up to 15 meters. Height of stilt floor shall not exceed 2.75 meters. In case of non-residential occupancies on sites below 750 sq. meters, for parking a semi-basement of 3 meters height and with such height not exceeding 1.5 meters above ground level may be considered. In case of parking floors where mechanical system and lift are provided, height of such parking floor upto 4.0 meters could be considered.
(c) Wherever cellars/sub-basements are permissible, these are excluded from height of Building
(d) No Balcony projection shall be allowed to extend on to the minimum setbacks.
These if provided, shall be within the minimum setback required to be left. However, a portico without access to the top may be considered in the front open space.
(e) In case of Sl. Nos. 4 to 8 of Table - III, stepped type buildings or incremental type buildings may be allowed only in respect of individual residential or educational / institutional buildings and such incremental development would be considered only after a minimum time period of 5 years.
(f) As per the provisions of the AP Fire Service Act, 1999, commercial buildings of height 15 meters and above, and buildings of public congregation like schools, cinema theatres, function halls and other assembly buildings on plot area of 500 sq. meters and above or of height above 6 meters are required to obtain prior clearance from Fire Department from fire and life safety point of view.
(g) The setbacks are required to be left after leaving the affected area of the plot / site, if any, for road widening. In respect of owners who surrender land affected in road widening free of cost, would be eligible for concessions in setbacks under G.O. Ms. No.15 M.A., dated 15-01-1998 and instructions issues by the Government from time to time.
(h) Building line is from the edge of the Road Right-of-way (whether existing or proposed).
(i) Where the lighting and ventilation of a building is through the means of a chowk or inner courtyard or interior open space/duct, such open space shall be open to sky and of area at least 9.0 sq. meters and no side shall be less than 1.5 meters in case of buildings of height up to 12 meters and in case of buildings of height above 12 meters no side shall be less than 2 meters.
(j) A strip of at least 1.0 meters greenery/lawn along the frontage of the site within the front setback shall be compulsorily developed and maintained with greenery and trees.
(k) For plots above 200 sq. meters, in addition to (vi) above, a minimum 1 meter wide continuous green planting strip in the periphery on remaining sides are required to be developed and maintained within the setback.
(l) For all residential / Institutional / Industrial plots above 750 Sq. meters, in addition to (vi) and (vii) above, 5% of the site area has to be developed as tot-lot / landscaped area and trees planted and maintained. Such organised open space could be in more than one location and shall be open to sky and shall be of a minimum width of 3 meters.
(m) To enhance the streetscape in respect of 18 meters and above roads, no front compound wall is recommended along the front setback. Only iron grill or low height green hedge and / or with sloping type planters is recommended along such roads.
(n) In all plots 750 sq. meters and above, provision shall be made for earmarking an area of 3 meter x 3 meter for the purpose of setting of public utilities like electricity distribution transformer, etc. within the owner's site and located in a corner splay of setback subject to mandated public safety requirements, ensuring turning radius for vehicles etc.
(o) If the above greenery mentioned at (j) to (l) above and Rule 9.10 is not maintained, 10% of additional Property tax every year would be imposed as penalty by the sanctioning authority till the condition is fulfilled.
(p) In case of plots above 300 sq. meters and upto 750 sq. meters, it is permitted to transfer up to one meter of setback from one side to the other side, and in case of plots above 750 sq. meters, it is permitted to transfer up to 2 meters of setback, which needs to be uniform at any given point, subject to maintaining of minimum building line in the front.
(q) In case of corner plots or plots abutting two or more roads, the front setback shall be as per the building line for the road having maximum width.
(r) For narrow plots where the length is 4 times the width of the plot or more, the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of 1 meter on each side.
(s) The space between 2 blocks shall be as given in Table-V.
(t) The height of the building will be calculated after excluding the parking floors for the purpose of computation of minimum setbacks to be left.
(u) Where all the owners of sites along the abutting road come forward for widening of the road by undertaking preparation of a Road Development Plan which would improve circulation in the area and duly approved by the competent authority, and by leaving the area affected in the widening of such road free of cost and implement it within one year, then higher height of the corresponding widened road width would be considered for such sites.
(v) Splay at road junctions, including Y-junctions shall be provided as follows:
• 3.0 meters x 3.0 meters offset/splay if the width of the road is 12 meters or less;
• 4.5 meters x 4.5 meters offset/splay if the width of the road is above 12 meters but less than 24 meters in width;
• 6.0 meters x 6.0 meters offset/splay if the width of the road is above 24 meters;
• In case of road junctions of different widths, a combination of the above as the case may be shall be ensured;
• The area of such splay would be deemed to form part of the road junction. No compound wall or any structure shall be allowed to be constructed in the splay area.
(ii) For the purpose of these Rules, the following conversion from M.K.S. and F.P.S. system shall be reckoned:
(i) 3 meters= 10 ft
(iv) 9 meters= 30 ft
(vii) 18 meters= 60
ft
(x) 45 meters=150 ft
( ii) 6 meters= 20 ft
(v) 12 meters= 40 ft
(viii) 24 meters= 80
ft
(xi) 60 meters= 200 ft.
(iii) 7.5 meters= 25
ft
(vi) 15 meters= 50 ft
(ix) 30 meters= 100 ft
Table - III
Table - III
Sl No
Plot Size (in sq
meters)
Parking provision
Height permissible
(in meters)
Building line or
minimum front setback (in meters) to be left
Minimum setbacks on
remaining sides (in meters)
Abutting road width
Up to 12
Above 12 & up to
18
Above 18 & up to
24
Above 24 & upto
30
Above 30
1
2
3
4
5
6
7
8
9
10
1
Less than 100
-
7
1
1
3
3
3
-
2
100 & upto 200
-
10
1.5
1.5
3
3
3
1.0
3
Upto 3 Above 200 & upto 300
Stilt Upto 7 parking floor allowed
2
4
5
6
7.5
1.0
Upto 10
3
4
5
6
7.5
1.5
4
Above 300 & upto 500
Stilt parking floor allowed
Upto 7
3
4
5
6
7.5
2.0
Upto 12
3
4
5
6
7.5
2.5
5.
Above 500 & upto 1000
Stilt parking + One Cellar floor allowed
Upto 7
3
4
5
6
7.5
3.0
Upto 12
3
4
5
6
7.5
3.5
Below 15
3
4
5
6
7.5
4
6
Above 1000
Stilt parking+2 Cellar floors allowed
Upto 7
3
4
5
6
7.5
3.5
Upto 12
3
4
5
6
7.5
4
Below 15
3
4
5
6
7.5
5
Below 18*
3
4
5
6
7.5
6
(a) Provision of Joint Open Space in certain cases:
(b) The building requirements and standards other than heights and setbacks specified in the National Building Code of India, 2005 shall be complied with.
(c) Such buildings shall be undertaken by owners by engaging registered architects/licenced builders/developers and licenced structural engineers. The designs and building plans shall be countersigned by the owner, licenced developer, registered architect, licenced engineer and a qualified & licenced structural Engineer who shall be responsible for the supervision, structural safety, earthquake safety, fire safety and specifications compliance of such buildings. Buildings shall be designed for compliance with earth quake resistance and resisting other natural hazards. The Completion Certificate shall contain that the norms have been followed in the design and construction of buildings for making the buildings resistant to earthquake, compliance with structural safety and fire safety requirements.
(d) The work of the building services like sanitation, plumbing, fire safety requirements, lifts, electrical installations, and other utility services shall be executed under the planning, design and supervision of qualified and competent technical personnel.
(e) The parking requirements shall be complied as given in these rules. The parking facilities and vehicles driveways etc. shall be maintained to the satisfaction of the sanctioning Authority.
(f) Shall provide solar water heating system in the building and solar lighting in the site for outdoor lighting within the site, etc. and give a bank guarantee to this effect to the sanctioning authority for compliance of the same.
(g) All Public and semi-public buildings including Assembly Buildings/Commercial complexes and other Public Congregation Buildings with covered area above 300 sq m shall be designed and constructed to provide facilities to the physically handicapped persons as prescribed in the National Building Code of India, 2005.
(h) In all buildings irrespective of above height provisions, the requirements of parts of the building like size and area requirements of habitable rooms, kitchen, bathrooms and Water closets, other areas, corridor and staircase widths, service ducts, etc. shall conform to the National Building Code of India,2005.
(i) All environmental aspects like provision of Rain water harvesting structures, greenery, solar heating and area lighting systems, Andhra Pradesh Water, Land & Tree Act provisions, etc., shall be complied with in such of the sites and Schemes where these are applicable.
Section 7 • Andhra Pradesh Municipalities Development Control Rules, 2008
7. Permissible Height & Setback Requirements.
andhra-pradesh-municipalities-development-control-rules-2008-sec-7.json
•
Section 7
{
"act_title": "Andhra Pradesh Municipalities Development Control Rules, 2008",
"act_slug": "andhra-pradesh-municipalities-development-control-rules-2008",
"section_label": "Section",
"section": {
"number": "7",
"title": "7. Permissible Height & Setback Requirements.",
"chapter": null,
"content": "(i) The permissible coverage would be as per the minimum setbacks to be left within the given site. The minimum setbacks and permissible height would be as per Table - III given below and shall be permissible subject to the following conditions:\n(a) Buildings of height above 15 meters and below 18 meters in Sl. No. 8 of Table - III, shall be permitted only if such plots abut roads of 12 meters minimum width.\n(b) Stilt parking floor permissible is exclusive of height of building up to 15 meters. Height of stilt floor shall not exceed 2.75 meters. In case of non-residential occupancies on sites below 750 sq. meters, for parking a semi-basement of 3 meters height and with such height not exceeding 1.5 meters above ground level may be considered. In case of parking floors where mechanical system and lift are provided, height of such parking floor upto 4.0 meters could be considered.\n(c) Wherever cellars/sub-basements are permissible, these are excluded from height of Building\n(d) No Balcony projection shall be allowed to extend on to the minimum setbacks.\nThese if provided, shall be within the minimum setback required to be left. However, a portico without access to the top may be considered in the front open space.\n(e) In case of Sl. Nos. 4 to 8 of Table - III, stepped type buildings or incremental type buildings may be allowed only in respect of individual residential or educational / institutional buildings and such incremental development would be considered only after a minimum time period of 5 years.\n(f) As per the provisions of the AP Fire Service Act, 1999, commercial buildings of height 15 meters and above, and buildings of public congregation like schools, cinema theatres, function halls and other assembly buildings on plot area of 500 sq. meters and above or of height above 6 meters are required to obtain prior clearance from Fire Department from fire and life safety point of view.\n(g) The setbacks are required to be left after leaving the affected area of the plot / site, if any, for road widening. In respect of owners who surrender land affected in road widening free of cost, would be eligible for concessions in setbacks under G.O. Ms. No.15 M.A., dated 15-01-1998 and instructions issues by the Government from time to time.\n(h) Building line is from the edge of the Road Right-of-way (whether existing or proposed).\n(i) Where the lighting and ventilation of a building is through the means of a chowk or inner courtyard or interior open space/duct, such open space shall be open to sky and of area at least 9.0 sq. meters and no side shall be less than 1.5 meters in case of buildings of height up to 12 meters and in case of buildings of height above 12 meters no side shall be less than 2 meters.\n(j) A strip of at least 1.0 meters greenery/lawn along the frontage of the site within the front setback shall be compulsorily developed and maintained with greenery and trees.\n(k) For plots above 200 sq. meters, in addition to (vi) above, a minimum 1 meter wide continuous green planting strip in the periphery on remaining sides are required to be developed and maintained within the setback.\n(l) For all residential / Institutional / Industrial plots above 750 Sq. meters, in addition to (vi) and (vii) above, 5% of the site area has to be developed as tot-lot / landscaped area and trees planted and maintained. Such organised open space could be in more than one location and shall be open to sky and shall be of a minimum width of 3 meters.\n(m) To enhance the streetscape in respect of 18 meters and above roads, no front compound wall is recommended along the front setback. Only iron grill or low height green hedge and / or with sloping type planters is recommended along such roads.\n(n) In all plots 750 sq. meters and above, provision shall be made for earmarking an area of 3 meter x 3 meter for the purpose of setting of public utilities like electricity distribution transformer, etc. within the owner's site and located in a corner splay of setback subject to mandated public safety requirements, ensuring turning radius for vehicles etc.\n(o) If the above greenery mentioned at (j) to (l) above and Rule 9.10 is not maintained, 10% of additional Property tax every year would be imposed as penalty by the sanctioning authority till the condition is fulfilled.\n(p) In case of plots above 300 sq. meters and upto 750 sq. meters, it is permitted to transfer up to one meter of setback from one side to the other side, and in case of plots above 750 sq. meters, it is permitted to transfer up to 2 meters of setback, which needs to be uniform at any given point, subject to maintaining of minimum building line in the front.\n(q) In case of corner plots or plots abutting two or more roads, the front setback shall be as per the building line for the road having maximum width.\n(r) For narrow plots where the length is 4 times the width of the plot or more, the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of 1 meter on each side.\n(s) The space between 2 blocks shall be as given in Table-V.\n(t) The height of the building will be calculated after excluding the parking floors for the purpose of computation of minimum setbacks to be left.\n(u) Where all the owners of sites along the abutting road come forward for widening of the road by undertaking preparation of a Road Development Plan which would improve circulation in the area and duly approved by the competent authority, and by leaving the area affected in the widening of such road free of cost and implement it within one year, then higher height of the corresponding widened road width would be considered for such sites.\n(v) Splay at road junctions, including Y-junctions shall be provided as follows:\n• 3.0 meters x 3.0 meters offset/splay if the width of the road is 12 meters or less;\n• 4.5 meters x 4.5 meters offset/splay if the width of the road is above 12 meters but less than 24 meters in width;\n• 6.0 meters x 6.0 meters offset/splay if the width of the road is above 24 meters;\n• In case of road junctions of different widths, a combination of the above as the case may be shall be ensured;\n• The area of such splay would be deemed to form part of the road junction. No compound wall or any structure shall be allowed to be constructed in the splay area.\n(ii) For the purpose of these Rules, the following conversion from M.K.S. and F.P.S. system shall be reckoned:\n(i) 3 meters= 10 ft\n(iv) 9 meters= 30 ft\n(vii) 18 meters= 60\n\t\t\t\tft\n(x) 45 meters=150 ft\n( ii) 6 meters= 20 ft\n(v) 12 meters= 40 ft\n(viii) 24 meters= 80\n\t\t\t\tft\n(xi) 60 meters= 200 ft.\n(iii) 7.5 meters= 25\n\t\t\t\tft\n(vi) 15 meters= 50 ft\n(ix) 30 meters= 100 ft\nTable - III\nTable - III\nSl No\nPlot Size (in sq\n\t\t\t\t\tmeters)\nParking provision\nHeight permissible\n\t\t\t\t\t(in meters)\nBuilding line or\n\t\t\t\t\tminimum front setback (in meters) to be left\nMinimum setbacks on\n\t\t\t\t\tremaining sides (in meters)\nAbutting road width\nUp to 12\nAbove 12 & up to\n\t\t\t\t\t18\nAbove 18 & up to\n\t\t\t\t\t24\nAbove 24 & upto\n\t\t\t\t\t30\nAbove 30\n1\n2\n3\n4\n5\n6\n7\n8\n9\n10\n1\nLess than 100\n-\n7\n1\n1\n3\n3\n3\n-\n2\n100 & upto 200\n-\n10\n1.5\n1.5\n3\n3\n3\n1.0\n3\nUpto 3 Above 200 & upto 300\nStilt Upto 7 parking floor allowed\n2\n4\n5\n6\n7.5\n1.0\nUpto 10\n3\n4\n5\n6\n7.5\n1.5\n4\nAbove 300 & upto 500\nStilt parking floor allowed\nUpto 7\n3\n4\n5\n6\n7.5\n2.0\nUpto 12\n3\n4\n5\n6\n7.5\n2.5\n5.\nAbove 500 & upto 1000\nStilt parking + One Cellar floor allowed\nUpto 7\n3\n4\n5\n6\n7.5\n3.0\nUpto 12\n3\n4\n5\n6\n7.5\n3.5\nBelow 15\n3\n4\n5\n6\n7.5\n4\n6\nAbove 1000\nStilt parking+2 Cellar floors allowed\nUpto 7\n3\n4\n5\n6\n7.5\n3.5\nUpto 12\n3\n4\n5\n6\n7.5\n4\nBelow 15\n3\n4\n5\n6\n7.5\n5\nBelow 18*\n3\n4\n5\n6\n7.5\n6\n(a) Provision of Joint Open Space in certain cases:\n(b) The building requirements and standards other than heights and setbacks specified in the National Building Code of India, 2005 shall be complied with.\n(c) Such buildings shall be undertaken by owners by engaging registered architects/licenced builders/developers and licenced structural engineers. The designs and building plans shall be countersigned by the owner, licenced developer, registered architect, licenced engineer and a qualified & licenced structural Engineer who shall be responsible for the supervision, structural safety, earthquake safety, fire safety and specifications compliance of such buildings. Buildings shall be designed for compliance with earth quake resistance and resisting other natural hazards. The Completion Certificate shall contain that the norms have been followed in the design and construction of buildings for making the buildings resistant to earthquake, compliance with structural safety and fire safety requirements.\n(d) The work of the building services like sanitation, plumbing, fire safety requirements, lifts, electrical installations, and other utility services shall be executed under the planning, design and supervision of qualified and competent technical personnel.\n(e) The parking requirements shall be complied as given in these rules. The parking facilities and vehicles driveways etc. shall be maintained to the satisfaction of the sanctioning Authority.\n(f) Shall provide solar water heating system in the building and solar lighting in the site for outdoor lighting within the site, etc. and give a bank guarantee to this effect to the sanctioning authority for compliance of the same.\n(g) All Public and semi-public buildings including Assembly Buildings/Commercial complexes and other Public Congregation Buildings with covered area above 300 sq m shall be designed and constructed to provide facilities to the physically handicapped persons as prescribed in the National Building Code of India, 2005.\n(h) In all buildings irrespective of above height provisions, the requirements of parts of the building like size and area requirements of habitable rooms, kitchen, bathrooms and Water closets, other areas, corridor and staircase widths, service ducts, etc. shall conform to the National Building Code of India,2005.\n(i) All environmental aspects like provision of Rain water harvesting structures, greenery, solar heating and area lighting systems, Andhra Pradesh Water, Land & Tree Act provisions, etc., shall be complied with in such of the sites and Schemes where these are applicable.",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
"prev_section": "6",
"next_section": "8"
}