    "act_title": "The Static and Mobile Pressure Vessels (Unfired) Rules, 2016",
    "act_slug": "the-static-and-mobile-pressure-vessels-unfired-rules-2016",
    "section_label": "Section",
    "section": {
        "number": "14",
        "title": "14. Design pressure.",
        "chapter": null,
        "content": "(a) the vapour pressure of the gas in the vessel at 550 C, if the vessel is meant for the storage of liquefiable gases:\n(b) the developed pressure of the gas in the vessel at 550 C, if the vessel is meant for the storage of a permanent gas;\n(c) the maximum allowable service pressure with additional allowances for vacuum and static head or surge due to acceleration or deceleration, as the case may be, in respect of the cryogenic liquid proposed to be stored or transported.\n(ii) (a) The static head (higher of the water column or the compressed gas column) shall also be considered for static pressure vessels.\n(b) The wind load, seismic loads shall also be considered for vertical cylindrical vessels and horton spheres.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 13
    },
    "prev_section": "13",
    "next_section": "15"
}