    "act_title": "The Static And Mobile Pressure Vessels (Unfired) Rules, 1981",
    "act_slug": "the-static-and-mobile-pressure-vessels-unfired-rules-1981",
    "section_label": "Section",
    "section": {
        "number": "31",
        "title": "31. Electrical apparatus and installations",
        "chapter": null,
        "content": "(i) all electrical meters, distribution boards, switches, fuses, plugs and sockets shall be of flame proof construction complying with the requirements of IS : 2148 : 1968 and the frames shall be effectively earthed;\n(ii) all electrical fixed lamps shall be enclosed in a well glass flame proof fitting conforming to IS : 2206 (Part I) : 1962.\n[31-A. Classification of hazardous area for flammable gases\n(a) a division \"0\" area, if inflammable gases of vapours are expected to be continuously present in the area;\n(b) a division \"1\" area, if inflammable gases or vapours are likely to be present in the area under normal operating conditions; or\n(c) a division \"2\" area, if inflammable gases or vapours are likely to be present in the area only under abnormal operating conditions or failure or rupture of an equipment.\n31-B. Extent of hazardous area\n(i) Entire space within the dispenser enclosure cabinet and forty-six centimetres horizontally from the exterior of enclosure cabinet and up to an elevation of one hundred and twenty-two centimetres above dispenser base and the entire pit or open space beneath the dispenser shall be division \"1\";\n(ii) Up to forty-six centimetres vertically, above the surrounding ground level and horizontally beyond forty-six centimetres up to six metres on all sides of the dispenser enclosure cabinet shall be division \"2\".]",
        "footnote": "",
        "is_definition": false,
        "sort_order": 29
    },
    "prev_section": "30",
    "next_section": "32"
}