    "act_title": "The Static And Mobile Pressure Vessels (Unfired) Rules, 1981",
    "act_slug": "the-static-and-mobile-pressure-vessels-unfired-rules-1981",
    "section_label": "Section",
    "section": {
        "number": "21",
        "title": "21. General",
        "chapter": null,
        "content": "(a) diameter of the vessel, in case of vessels with water capacity not exceeding forty thousand litres,\n(b) fifteen metres, if the water capacity of the vessels exceeds forty thousand litres.]\n[22. Location of pressure vessel\nTABLE 1\nMINIMUM SAFETY\nDISTANCES FOR CORROSIVE, TOXIC OR PERMANENT FLAMMABLE GASES\nSl. Nos Water capacity of vessel(in litres) Minimum distance From building or group of buildings or line of adjoining property Minimum distance between pressure vessels (1) (2) (3) (4) (i) (ii) (iii) (iv) (v) Not above 2000 Above 2000 but not above 10,000 Above 10,000 but not above 20,000 Above 20,000 but not above 40,000 Above 40,000 5 metres 10 metres 15 metres 20 metres 30 metres 1 metre 1 metre 1.5 metres 2 metres 2 metres\nSl.\nNos\nWater capacity of vessel(in litres)\nMinimum distance\nFrom building or group of buildings or line of\nadjoining property\nMinimum distance\nbetween pressure\nvessels\n(1)\n(2)\n(3)\n(4)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\nNot above 2000\nAbove 2000 but not above 10,000\nAbove 10,000 but not above 20,000\nAbove 20,000 but not above 40,000\nAbove 40,000\n5 metres\n10 metres\n15 metres\n20 metres\n30 metres\n1 metre\n1 metre\n1.5 metres\n2 metres\n2 metres\nTABLE 2\nMinimum safety distances for non-corrosive, non-flammable or non-toxic gases\nSl. Nos Water capacity of vessel(in litres) Minimum distance from building or group of buildings or line of adjoining property Minimum distance between pressure vessels (1) (2) (3) (4) (i) (ii) (iii) (iv) (v) Not above 2000 Above 2000 but not above 10,000 Above 10,000 but not above 20,000 Above 20,000 but not above 40,000 Above 40,000 3 metres 5 metres 7.5 metres 10 metres 15 metres 1 metre 1 metre 1.5 metres 2 metres 2 metres\nSl.\nNos\nWater capacity of vessel(in litres)\nMinimum distance from\nbuilding or group of\nbuildings or line of\nadjoining property\nMinimum distance\nbetween pressure\nvessels\n(1)\n(2)\n(3)\n(4)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\nNot above 2000\nAbove 2000 but not above 10,000\nAbove 10,000 but not above 20,000\nAbove 20,000 but not above 40,000\nAbove 40,000\n3 metres\n5 metres\n7.5 metres\n10 metres\n15 metres\n1 metre\n1 metre\n1.5 metres\n2 metres\n2 metres\nTABLE  3\nMinimum safety distances for liquefied\nflammable gases\nSl. No. Water capacity of vessel (in litres) Minimum distance from building or group of buildings or line of adjoining property Minimum distance between vessels Above ground level Underground or Aboveground vessels covered with earth(mound) Above ground level Underground or aboveground vessels covered with earth(mound) (1) (2) (3) (4) (5) (6) (i) (ii) (iii) (iv) (v) (vi) (vii) (viii) (ix) (x) Not above 2000 Above 2000 but not above 75,00 Above 75,00 but not above 10,000 Above 10,000 but not above 20,000 Above 20,000 but not above 40,000 Above 40,000 but not above 3,50,000 Above 3,50,000 but not above 4,50,000 Above 4,50,000 but not above 7,50,000 Above 7,50,000 but not above 38,00,000 Above 38,00,000 5 metres 10 metres 10 metres 15 metres 20 metres 30 metres 40 metres 60 metres 90 metres 120 metres 3 metres 3 metres 5 metres 7.5 metres 10 metres 15 metres 15 metres 15 metres 15 metres 15 metres 1 metre 1 metre 1.5 metres 2 metres 2 metres 2 metres or ¼ th of the sum of the sum of diameter of adjacent vessel or ½ the diameter of the two adjacent vessels, whichever is greater 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre\nSl.\nNo.\nWater capacity of vessel\nMinimum distance from building or group of buildings or line of\nMinimum distance between\nAbove\nground\nlevel\nUnderground or Aboveground vessels covered\nwith\nAbove\nground\nlevel\nUnderground or aboveground\nvessels covered\nwith earth(mound)\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\n(vi)\n(vii)\n(viii)\n(ix)\n(x)\nNot above 2000\nAbove 2000 but not above 75,00\nAbove 75,00 but not above 10,000\nAbove 10,000 but not above 20,000\nAbove 20,000 but not above 40,000\nAbove 40,000 but not above 3,50,000\nAbove 3,50,000 but not above 4,50,000\nAbove 4,50,000 but not above 7,50,000\nAbove 7,50,000 but not above 38,00,000\nAbove 38,00,000\n5 metres\n10 metres\n10 metres\n15 metres\n20 metres\n30 metres\n40 metres\n60 metres\n90 metres\n120 metres\n3 metres\n3 metres\n5 metres\n7.5 metres\n10 metres\n15 metres\n15 metres\n15 metres\n15 metres\n15 metres\n1 metre\n1 metre\n1.5 metres\n2 metres\n2 metres\n2 metres or ¼ th\nof the sum of\nthe sum of\ndiameter of\nadjacent vessel\nor ½ the\ndiameter of the\ntwo adjacent\nvessels,\nwhichever is\ngreater\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\nTABLE  4\nMinimum Safety distances (in meters) between\nfacilities associated with storage of liquefied flammable gas in petroleum\nrefinery, gas processing plants, storage terminals and bottling plants.\n(A) For Total Storage not Above 100\nTonnes\n(A) For Total Storage not Above 100\nTonnes\nFrom/To Storage Vessel Property line/ buildings not associated with storage and operation Sheds for filling storage, evacuation of cylinders Tank Truck loading/ unloading gantry Tank Wagon gantry Pump/ compres sor Shed Fire Water Pump room (1) (2) (3) (4) (5) (6) (7) (8) Storage vessel Table -3 Table - 3 30 30 50 15 60 Property line/ buildings not associated with storage and operation Table -3 ----- 30 30 50 30 -- Sheds for filling storage, evacuation of cylinders 30 30 15 30 50 15 60 Tank Truck loading/ unloading gantry 30 30 30 30 50 30 60 Tank Wagon gantry 50 50 50 50 50 30 60 Pump/compressor Shed 15 30 15 30 30 --- 60 Fire Water Pump room 60 --- 60 60 60 60 ---\nFrom/To\nStorage\nVessel\nProperty line/ buildings not\nassociated\nwith storage\nand operation\nSheds for\nfilling\nstorage,\nevacuation\nof\ncylinders\nTank Truck\nloading/\nunloading\ngantry\nTank\nWagon\ngantry\nPump/\ncompres\nsor\nShed\nFire\nWater\nPump\nroom\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n(7)\n(8)\nStorage vessel\nTable -3\nTable - 3\n30\n30\n50\n15\n60\nProperty line/\nbuildings not\nassociated with\nstorage and\noperation\nTable -3\n-----\n30\n30\n50\n30\n--\nSheds for filling\nstorage,\nevacuation of\ncylinders\n30\n30\n15\n30\n50\n15\n60\nTank Truck\nloading/\nunloading gantry\n30\n30\n30\n30\n50\n30\n60\nTank Wagon\ngantry\n50\n50\n50\n50\n50\n30\n60\nPump/compressor\nShed\n15\n30\n15\n30\n30\n---\n60\nFire Water Pump\nroom\n60\n---\n60\n60\n60\n60\n---\n(B) For Total Storage not Above 100\nTonnes\n(B) For Total Storage not Above 100\nTonnes\nFrom/To Storage Vessel Property line/ buildings not associated with storage and operation Sheds for filling storage, evacuation of cylinders Tank truck unloading/ loading gantry Fire Water Pump room (1) (2) (3) (4) (5) (6) Storage Vessel Table-3 Table 3 Table - 3 15 30 Property line/buildings not associated with storage & operation Table-3 ----- 15 15 -- Sheds for filling storage, evacuation of cylinders Table - 3 15 15 15 30 Tank truck unloading/loading gantry 15 15 15 15 30 Fire Water Pump room 30 -- 30 30 --\nFrom/To\nStorage\nVessel\nProperty line/\nbuildings not\nassociated\nwith storage\nand operation\nSheds for filling\nstorage,\nevacuation of\ncylinders\nTank truck\nunloading/\nloading gantry\nFire\nWater\nPump\nroom\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\nStorage Vessel\nTable-3\nTable 3\nTable - 3\n15\n30\nProperty line/buildings not\nassociated with storage &\noperation\nTable-3\n-----\n15\n15\n--\nSheds for filling storage,\nevacuation of cylinders\nTable - 3\n15\n15\n15\n30\nTank truck\nunloading/loading gantry\n15\n15\n15\n15\n30\nFire Water Pump room\n30\n--\n30\n30\n--\nTABLE 5\nMinimum Safety distances (in metres) between\nfacilities associated with storage and dispensing of liquefied petroleum gas in\nliquefied Petroleum gas dispensing station as automotive fuel to motor vehicles .\nTo/ From Liquefied Petroleu mLPG Storage Vessels Fill point of LPG Storage vessel and Centre of LPG Tank-Truck unloading hard stand Liquefied petroleum gas Dispenser Property line Petroleum Class A or B service Station licensed in Form XII of Petroleum Rules 1976 Fill point of petroleum tanks Vent pipe Of petrolem tanks Petroleum Class A/B dispensig pump Liquefied petroleum gas storage vessels Table-3 9 (aboveground/ mounded vessels exceeding 7500 litres capacity) 6 (aboveground/ mounded vessels not exceeding 7500 litres capacity ) 3 (underground vessel) 15 (aboveground vessels exceeding 20,000 litres capacity) 9 (aboveground vessels not exceeding 20,000 litres capacity or underground/ mounded vessels) Table-3 9 9 9 Fill point of LPG Storage vessel and Centre of LPG Tank- Truck unloading hard stand 9 (abovegr ound/ mounded vessels exceedin g 7500 litres capacity) 6 (abovegr ound/ mounded vessels not exceeding 7500 litres capacity) 3 (underground vessel) - 6 9 6 6 6 Liquefied Petroleum Gas Dispenser 9 ( aboveground vessels not exceeding 20,000 litres capacity or underground/mounded vessels ) 15 ( aboveground vessels exceeding 20,000 litres capacity ) 6 - 6 6 6 6 Property line T able 3 9 6 - 3 4 6\nTo/ From\nLiquefied\nPetroleu\nmLPG\nStorage\nVessels\nFill point of LPG\nStorage\nvessel and Centre\nof LPG\nTank-Truck\nunloading hard\nstand\nLiquefied petroleum gas Dispenser\nProperty\nline\nPetroleum Class A or B service Station licensed in Form XII of Petroleum Rules 1976\nFill point of petroleum\ntanks\nVent pipe\nOf petrolem\ntanks\nPetroleum\nClass\nA/B\ndispensig\npump\nLiquefied petroleum gas storage vessels\nTable-3\n9 (aboveground/\nmounded\nvessels exceeding\n7500\nlitres capacity)\n6 (aboveground/\nmounded\nvessels not\nexceeding\n7500 litres\ncapacity ) 3 (underground\nvessel) 15 (aboveground vessels exceeding 20,000 litres capacity)\n9 (aboveground\nvessels not\nexceeding\n20,000 litres\ncapacity or\nunderground/\nmounded\nvessels)\nTable-3\n9\n9\n9\nFill point\nof LPG\nStorage\nvessel and\nCentre of\nLPG\nTank-\nTruck\nunloading\nhard stand\n9\n(abovegr\nound/\nmounded\nvessels\nexceedin\ng 7500\nlitres\ncapacity)\n6\n(abovegr\nound/\nmounded\nvessels not exceeding 7500 litres capacity) 3 (underground vessel)\n-\n6\n9\n6\n6\n6\nLiquefied Petroleum Gas Dispenser\n9 ( aboveground vessels not exceeding 20,000 litres capacity or underground/mounded vessels ) 15 ( aboveground vessels exceeding 20,000 litres capacity )\n6\n-\n6\n6\n6\n6\nProperty line\nT able 3\n9\n6\n-\n3\n4\n6\n[TABLE 6\nMinimum safety distances for non-flammable non\ntoxic cryogenic liquids\nWater capacity of vessel in litres Between Two vesse Between vessel and any building or adjoining property line or pedestrians passage Between vessel and flammable structure, naked flame, pipeline, containing flammable fluids, electric installation or places of public assembly or drain Not exceeding 10,000 Exceeding 10,000 1 metre 1 metre 3 metres 3 metres 5 metres 7.5 metres\nWater capacity of\nvessel in litres\nBetween\nTwo\nvesse\nBetween vessel and\nany building or\nadjoining property line\nor pedestrians\npassage\nBetween vessel and\nflammable structure,\nnaked flame, pipeline,\ncontaining flammable\nfluids, electric\ninstallation or places\nof public assembly or\ndrain\nNot exceeding 10,000\nExceeding 10,000\n1 metre\n1 metre\n3 metres\n3 metres\n5 metres\n7.5 metres\nTABLE 7\nMinimum safety distances for liquid\ncarbon-dioxide\nWater capacity of vessel in litres Between Two vessel Between vessel and any building or adjoining property line or pedestrians passage or places of public assembly Not exceeding 50,000 1 metre 2 metres Exceeding 50,000 2 metre 4 metres\nWater capacity of\nvessel in litres\nBetween\nTwo\nvessel\nBetween vessel and\nany building or\nadjoining property line\nor pedestrians\npassage or places of\npublic assembly\nNot exceeding 50,000\n1 metre\n2 metres\nExceeding 50,000\n2 metre\n4 metres\n(a) thirty metres for corrosive, toxic or flammable gases;\n(b) fifteen metres for non-corrosive, non-toxic or non-flammable gases;",
        "footnote": "",
        "is_definition": false,
        "sort_order": 20
    },
    "prev_section": "20",
    "next_section": "23"
}