    "act_title": "The Punjab Factory Rules, 1952",
    "act_slug": "the-punjab-factory-rules-1952",
    "section_label": "Section",
    "section": {
        "number": "65",
        "title": "65. Exemption.",
        "chapter": null,
        "content": "(a) The operation of repairing a water-sealed gas-holder by the electric welding process, subject to the following conditions :-\n(i) The gas-holder shall contain only the following gases, separately or mixed at a pressure greater than atmospheric pressure, namely, town gas, coke-oven gas, producer gas, blast furnace gas, or gases, other than air used in their manufacture:\n(ii) Welding shall only be done by the electric welding processes and shall be carried out by experienced operatives under the constant supervision of a competent person.\n(b) The operations of cutting or welding steel or wrought iron gas mains and services by the application of heat subject to the following conditions :-\n(i) the main or service shall be situated in the open air, and it shall contain only the following gases, separately or mixed at a pressure greater than atmospheric pressure namely, gas, coke-oven gas, producer gas, blast furnace gas, or gases other than air used in their manufacture;\n(ii) the main or service shall not contain acetylene or any gas or mixture of gases to which acetylene has been added intentionally;\n(iii) the operation shall be carried out by an experienced person or persons and at least 2 persons (including those carrying out the operations) experienced in work on gas mains and over 18 years of age shall be present during the operations;\n(iv) the site of the operation shall be free from any inflammable or explosive gas or vapour;\n(v) where acetylene gas is used as a source of heat in connection with an operation, it shall be compressed and contained in a porous substance in a cylinder; and\n(vi) prior to the application of any flame to the gas main or service this shall be pierced or drilled and the escapping gas ignited.\n(c) The operation of repairing on oil tank on any ship by the electric welding process shall be subjected to the following conditions -\n(i) the only oil contained in the tank shall have a flash point of not less than 150 degree F. (close test) and a certificate to this effect shall be obtained from a competent analyst;\n(ii) the analyst's certificate shall be kept available for inspection by an Inspector, or by any person employed or working on the ship;\n(iii) the welding operation shall be carried out only on the exterior surface of the tank at a place (a) which is free oil or oil leakage in inflammable quantities and (b) which is not less than one below the nearest Part of the surface of the oil within the tank; and\n(iv) welding shall be done only by the electric welding and shall be carried out by experienced operatives under the constant supervision of a competent person.\n[66. Fire protection.]\n(1) Process, equipment, plants, etc., involving serious explosion and serious fire hazards.\n(b) All industrial processes involving serious fire hazards shall be located in buildings or work places separated from one another by walls of fire resistant construction.\n(c) Equipment and plant involving serious fire or flash fire hazards shall, wherever possible, be so constructed and installed that in case of fire, they can be easily isolated.\n(d) Ventilation ducts, pneumatic conveyers and similar equipment involving a serious fire risk shall be provided with flame-arresting or automatic fire extinguishing appliance, or fire resisting damps, electrically interlocked with heat sensitive or smoke detectors and the air-conditioning plant system.\n(e) In all work places having serious fire or flash fire hazards, passages between machines, installations or piles of material should be at least ninety centimeters wide and for storage piles, the clearance between the ceiling and the top of the pile should not be less than two metres.\n(2) Access for fighting.\n(b) Doors and windows opening shall be located in a suitable position on all external walls of the building to provide easy access to the entire area within the building for fire fighting.\n(3) Protection against lightning.\n(a) buildings in which explosive highly flammable substances are manufactured, used, handled or stored:\n(b) storage tanks containing oils, paints or other flammable liquid;\n(c) grain elevators;\n(d) buildings, tall chimneys or stacks where flammable gases, fumes dust or lint are likely to be present; and\n(e) sub-station buildings and out-door transformers and switch-yards.\n(4) Precautions against ignition.\n(a) all electrical apparatus shall either be excluded from the area of risk or they shall be of such construction and so installed and maintained as to prevent the danger of their being a source of ignition;\n(b) effective measures shall be adopted for prevention of accumulation of static charges to a dangerous extent;\n(c) workers shall wear shoes without iron or steel nails to cause sparks by friction;\n(d) smoking, lighting or carrying of matches, lighters, or smoking materials shall be prohibited.\n(e) transmission belts with iron fasteners shall not be used; and\n(f) all other precautions, as are reasonably practicable, shall be taken to prevent initiation of ignition from all other possible sources such as open flames, frictional sparks, overheated surfaces of machinery or plant, chemical or physico-chemical reaction and radiant heat.\n(5) Spontaneous ignition.\n(6) Cylinders containing compressed gas.\n(7) Storage of flammable liquids.\n(b) Flammable liquids shall be stored in closed containers and in limited quantities in well ventilated rooms of fire resisting construction which are isolated from the remainder of the building by fire walls and self closing fire doors.\n(c) Large quantities of such liquids shall be stored in an isolated and adequately ventilated building of fire resisting construction or in storage tanks preferably underground and at a distance from any building as required in the Petroleum Rules, 1976.\n(d) Effective steps shall be taken to prevent leakage of such liquids into basements, pumps or drains and to confine any escaping liquid within safe limits.\n(8) Accumulation of flammable dust, gas, fume or vapour in air or flammable waste material on the floors.\n(b) No waste material of flammable nature shall be permitted to accumulate on the floors and shall be removed at least once in a day or shift and more often, when possible. Such materials shall be placed in suitable metal containers with covers wherever possible.\n(9) Fire exits.\n(i) \"horizontal exit\", means an arrangement which allows alternative egress from a floor area to another floor at or near the same level in an adjoining building or an adjoining Part of the same building with adequate separation; and\n(ii) \"travel distance\" means the distance an occupant has to travel to reach an exit.\n(b) An exit may be a doorway, corridor, passageway to an external stairway or to a verandah or to an internal stairway segregated from the rest of building by fire resisting walls which shall provide continuous and protected means of egress to the exterior of a building or to an exterior open space. An exit may also include a horizontal exit leading to an adjoining building at the same level.\n(c) Lifts, escalator and revolving doors shall not be considered as exits for the purpose of this sub-rule.\n(d) In every room of a factory, exits sufficient to permit safe escape of the occupants in case of fire or other emergency shall be provided which shall be free of any obstruction.\n(e) The exits shall be clearly visible and suitably illuminated with suitable arrangement irrespective of the fact that whatever artificial lighting is to be adopted for this purpose, to maintain the required illumination in case of failure of the normal source of electric supply.\n(f) The exits shall be marked in a language understood by the majority of the workers.\n(g) Iron rung ladders or spiral staircases shall not be used as exit stair cases.\n(h) Fire resisting doors or roller shutters shall be provided at appropriate places along the escape routes to prevent spread of fire and smoke, Particularly at the entrance of lifts or stairs where funnel or flue effect may be created inducing an upward spread of fire.\n(i) All exits shall provide continuous means of egress to the exterior of a building or to an exterior open space leading to a street.\n(j) Exits shall be so located that the travel distance to reach at least one of them on the floor shall not exceed thirty metres.\n(k) In case of those factories where high hazard materials are stored or used, the travel distance to the exit shall not exceed twenty-two-and-a-half metres and there shall be at least two ways of escape from every room, however small except toilet rooms, so located that the points of access thereto, are out of, or suitably shielded from areas of high hazard.\n(l) Wherever more than one exit is required for any room, space or floor exits shall be placed as remote from each other as possible and shall be arranged to provide direct access in separate direction from any point in the area served.\n(m) The unit of exit width used to measure capacity of any exit shall be fifty centimetres. A clear width of twenty-five centimetres shall be counted as an additional half unit. Clear width of less than twenty-five centimeters shall not be counted for exit width.\n(n) Occupants per unit width shall be fifty for stairs and seventy-five for doors.\n(o) For determining the exits required, the occupant load shall be reckoned on the basis of actual number of occupants within any floor area of ten square metres per person, whichever is more.\n(p) There shall not be less than two exits serving every floor area above and below the ground floor, and at least one of them shall be an internal enclosed stairway.\n(q) For every building or structure used for storage only, and every section thereof considered separately, shall have access to at least one exit so arranged and located as to provide suitable means of escape for any person employed therein, and in any such room wherein ten persons may be normally present, at least two separate means of exit shall be available as remote from each other as practicable.\n(r) Every storage area shall have access to at least one means of exit which can be readily opened.\n(s) Every exit doorway shall open into an enclosed stairway, a horizontal exit or a corridor or passageway providing continuous and protected means of egress.\n(t) No exit doorway shall be less than one hundred centimeters width. Doorways shall not be less than two hundred centimeters in height.\n(u) Exit doorways shall open outwards, that is, away from the room but shall not obstruct the travel along any exit. No door when opened, shall reduce the required width of stairway of landing to less than ninety centimetres. Overhead or sliding doors shall not be installed for this purpose.\n(v) An exit door shall not open immediately upon a flight of stairs. A landing at least 1.5 metre x 1.5 metre in size shall be provided in the stairway at each doorway. The level of landing shall be the same as that of the floor which it serves.\n(w) The exist doorways shall be openable from the side which they serve without the use of a key.\n(x) Exit corridors and passageways shall be of a width not less than the aggregate required width of exit doorways leading from there in the direction of travel to the exterior.\n(y) Where stairways discharge through corridors and passageways, the height of the corridors and passageways shall not be less than 2.4 metres.\n(z) A staircase shall not be arranged round a lift shaft unless the latter is totally enclosed by a material having a fire-resistance rating not lower than that of type of construction of the former.\n(aa) Hollow combustible construction shall not be permitted.\n(bb) The minimum width of an internal staircase shall be one hundred centimetres.\n(cc) The minimum width of treads without nosing shall be twenty-five centimetres for an internal staircase. The treads shall be constructed and maintained in a manner to prevent slipping.\n(dd) The maximum height of a riser shall be nineteen centimetres and the number of risers shall be limited to twelve per flight.\n(ee) Hand rails shall be provided with a minimum height of one hundred centimetres and shall be firmly supported.\n(ff) The use of spiral staircase shall be limited to low occupant load and to a building of height of nine metres, unless they are connected to platforms such as balconies and terraces to allow escapees to pause. A spiral staircase shall be not less than three hundred centimetres in diameter and have adequate head room.\n(gg) The width of a horizontal exit shall be the same as for the exit doorways.\n(hh) The floor area on the opposite or refuge side of a horizontal exit shall be sufficient to accommodate occupants of the floor areas served, allowing not less than 0.3 square metre per person. The refuge area shall be provided with exits adequate to meet the requirements of this sub-rule. At lest one of the exits shall lead directly to the exterior or street.\n(ii) Where there is difference in level between connected areas for horizontal exit, ramps not more than one in eight slope shall be provided. For this purpose steps shall not be used.\n(jj) Doors in horizontal exits shall be openable at all times.\n(kk) Ramps with a slope of not more than one in ten may be substituted for the requirements of staircase. For all slopes exceeding in ten and wherever the use is such as to involve danger of slipping, the ramp shall be surfaced with non-slipping material.\n(ll) In any building, not provided with automatic fire alarm, a manual fire alarm system shall be provided if the total capacity of the building is over five hundred persons, or if more than twenty-five persons are employed above or below the ground floor, except that no manual fire alarm shall be required in one storey buildings where the entire area is undivided and all Parts thereof are clearly visible to all occupants.\n(10) First aid fire fighting arrangements.\n(b) The types of first-aid fire-fighting equipment to be provided shall be determined by considering the different types of fire risks which are classified as follows :-\n(i) \"light hazard\". - Occupancies like offices, assembly halls, canteens, rest-rooms, ambulance rooms and the like;\n(ii) \"ordinary hazard\". - Occupancies like saw mills, carpentry shop, small timber yards, book binding shops, engineering worshop and the like;\n(iii) \"extra hazard\". - Occupancies like large timber yards, godowns storing fibrous materials, flour mills, cotton mills, jute mills, large wood working factories and the like;\n(c) The number and types of first-aid fire fighting equipment to be provided for 'light hazard' occupancy shall be as given in Schedule I to this rule. For 'ordinary hazard' or 'extra hazard' occupancies, as the case may be, equipment as given in paragraph 12 shall be provided, in addition to that given in Schedule I to this rule.\n(d) The first-aid fire fighting equipment shall conform to the relevant Indian Standards.\n(e) As far as possible the first-aid fire-fighting equipment shall be similar in shape and appearance and shall have the same method of operation.\n(f) All first-aid fire fighting equipment shall be placed in a conspicuous position and shall be readily and easily accessible for immediate use. Generally, these equipments shall be placed as near as possible to the exits or stair landing or normal routes of escape.\n(g) All water buckets and bucket pump type extinguishers shall be filled with clean water. All sand buckets shall be filled with clean, dry and fine sand.\n(h) All other extinguishers shall be charged appropriately in accordance with the instructions of the manufacturer.\n(i) Each first-aid fire fighting equipment shall be allotted a serial number by which it shall be referred to in the records. The following details shall be painted with white paint on the body of each equipment, -\n(j) First-aid fire fighting equipment shall be placed on platforms or in cabinets in such a way that their bottom is seven hundred and fifty milimetres above the floor level. Fire buckets shall be placed on hooks attached to a suitable stand or wall in such a way that their bottom is seven hundred and fifty milimetres above the floor level. Such equipment if placed outside the building, shall be under sheds or covers.\n(k) All extinguishers shall be thoroughly cleaned and re-charged immediately after discharge. Sufficient refill material shall be kept readily available for this purpose at all times.\n(l) All first-aid fire fighting equipment shall be subjected to routine maintenance, inspection, and resting to be carried out by properly trained persons. Periodicity of the routine maintenance, inspection and test shall conform to Indian standards.\n(11) Other fire fighting arrangements.\nA - the total area in square metres of all floors including galleries in all buildings of the factory;\nB - the total area in square metres of all floors and galleries including open spaces in which combustible materials are handled or stored;\nC - the total area in square metres of all floors over fifteen metres above ground level; and\nD - the total area in square metres of all floors of all buildings other than those of fire resisting construction;\n(b) Each trailer pump shall be provided with equipment as per Schedule II appended to this rule. Such equipment shall conform to the relevant Indian Standards.\n(c) Trailer pumps shall be housed in a separate shed or sheds which shall be sited close to a principal sources of water supplies in the vicinity of the main risks of the factory.\n(d) In factories where the area is such as cannot be reached by man hauling of trailer pumps within reasonable time, vehicles with towing attachment shall be provided at the scale of one for every four trailer pumps with a minimum of one such vehicle kept available at all times.\n(e) Water supply shall be provided to give flow of water as required under clause (a) for at least one hundred minutes. At least fifty per cent of this water supply or four lac and fifty thousand litres whichever is less, shall be in the form of static tanks of adequate capacities (not less than four lac and fifty thousand litres each) distributed round the factory with due regard to the potential fire risks in the factory. Where piped supply is provided, the size of the main shall not be less than fifteen centimetres diameter and it shall be capable of supplying a minimum of four thousand five hundred litres per minute at a pressure of not less than seven kilograms per square centimetre.\n(12) Personnel in charge of equipment and for fire fighting, fire drills, etc.\n(b) Sufficient number of persons shall be trained in the proper handling of fire fighting equipment as referred to in clause (a) and their use against the types of fire for which they are intended to ensure that adequate number of persons are available for fire fighting both by means of first-aid fire fighting equipment and by other means. Such persons shall be provided with clothing and equipment including helmets, belts and boots, preferably gum- boots. Wherever vehicles with towing attachment are to be provided as required in clause (d) of sub-rule (11), sufficient number of persons shall be trained in driving these vehicles to ensure that trained persons are available for driving them whenever the need arises.\n(c) Fire fighting drills shall be held as often as necessary and at least once in every period of two months.\nSchedule I\nFirst-Aid Fire Fighting Equipments\nFirst-Aid Fire Fighting Equipments\nClass of Fire\nSuitable type of equipment\n1\n2\nA.\nFires in ordinary combustibles (wood, vegetable fibres, \n\t\t\t\tpaper and the like)\nChemical extinguishers of soda-acid, gas expelled water and\n\t\t\t\tanti- freeze types, and water buckets.\nB.\nFires inflammable liquids, paints grease, solvents and the\n\t\t\t\tlike\nChemical extinguishers of foam, carbondioxide and dry powder\n\t\t\t\ttypes and sand buckets.\nC.\nFires in gaseous substances under pressure\nChemical extinguishers of carbondioxide and dry powder types\nD.\nFires in reactive chemicals, active metals and the like\nSpecial type of dry powder extinguishers and sand buckets\nE.\nFires is Electrical equipments\nChemical extinguishers of carbondioxide and dry powder types\n\t\t\t\tand sand buckets.\nAcceptable Replacements\nBuckets of water\nWater type extinguishers\nFor one bucket\nFor three buckets\nFor each nine litres (or two gallons) extinguishers\nDry sand\nOne bucket\nThree buckets\nCarbondioxide extinguishers\nThree kilogram (or seven pounds)\nNine kilogram (or twenty pounds) (In not less than two\n\t\t\t\textinguishers)\nNine kilogram (or twenty pounds)\nDry powder\nTwo kilogram (or five pounds)\nFive kilogram (or eleven pounds) (In one or more\n\t\t\t\textinguishers)\nFive kilogram (or eleven pounds)\nFoam extinguishers\nNine litres (or two gallons)\nNine litres (or two gallons)\nNine litres (or two gallons)\n(a) For rooms containing electrical transformers, switch-gears, motors and/or other electrical apparatus only, not less than two kilograms dry powder or carbon dioxide type extinguishers shall be provided within fifteen metres of the apparatus.\n(b) Where motors and/or other electrical equipments are installed in rooms other than those containing such equipment only, one five kilogram dry powder or carbon dioxide extinguisher shall be installed within fifteen metres of such equipment in addition to the requirements mentioned in paras (3) and (4) above. For this purpose, the same extinguisher may be deemed to afford protection to all apparatus within fifteen metres thereof.\n(c) Where electrical motors are installed on platforms, one, two kilogram dry powder or carbon dioxide type extinguisher shall be provided on or below each platform. In case of a long platform with a number of motors, one extinguisher shall be acceptable as adequate for every three motors on the common platform. The above requirements shall be in addition to the requirements mentioned in paras (3) and (4) above.\n(a) While selecting sites for first aid fire fighting equipment, due consideration shall be given to the nature of the risk to be covered. The equipment shall be placed in conspicuous positions and shall be readily accessible for immediate use in all Parts of the occupancy. It should always be borne in mind while selecting sites that first-aid fire fighting equipment are intended only for use on incipient fires and their value may be negligible if the fire is not extinguished or brought under control in the early stages.\n(b) Buckets and extinguishes shall be placed at convenient and easily accessible locations either on hangers or on stands in such a way that their bottom is seven hundred and fifty milimetres above the floor level.\nSchedule II\nEquipment to be Provided with Trailer Pump\nEquipment to be Provided with Trailer Pump\n(A) For light trailer pump of a capacity of six hundred and eight litres per minute.\nOne Armoured suction hose of nine metres length, with wrenches.\nTwo Metal suction strainers.\nOne Basket strainer.\nOne Two way suction collecting-head.\nOne Suction adaptor.\nTen Unlined or rubber lined seventy milimetres delivery hose of twenty-five metres length complete with quick-release couplings.\nOne dividing breaching-piece.\nTwo branch-piece with fifteen milimeters nozzles.\nOne Diffuser nozzle.\nOne Standpipe with blank cap.\nOne Hydrant key.\nFour Collapsible canvas buckets.\nOne Fire hook (preventor) with cutting edge.\nOne Twenty-five milimetre manila rope of thirty metres length.\nOne Extension ladder of nine metres length (where necessary).\nOne Heavy axe.\nOne Spade.\nOne Pick axe.\nOne Crowbar.\nOne Saw.\nOne Hurricane lamp.\nOne Electric torch.\nOne Pair rubber gloves.\n(B) For large trailer pump of a capacity one thousand and eight hundred litres/minute.\nOne Armoured suction hose of nine metres length, with wrenches.\nOne Metal strainer.\nOne basket strainer.\nOne three-way suction collection head.\nOne suction adapter.\nFourteen unlined or rubber lined seventy milimetres delivery hoses of twenty-five metres length complete with quick-release couplings.\nOne dividing breaching piece.\nOne collecting breaching piece.\nFour branch pipes with one twenty-five milimetre, two twenty milimetre and one diffuser nozzle.\nTwo standpipes with blank caps.\nTwo hydrant keys.\nSix collapsible canvas buckets.\nOne ceiling hook (preventor) with cutting edge.\nOne fifty milimetre manila rope of thirty metres length.\nOne extension ladder of nine metres length (where necessary).\nOne heavy axe.\nOne spade.\nOne pick axe.\nOne crowbar.\nOne saw.\nOne hurricane lamp.\nOne electric torch.\nOne pair rubber gloves.\nNote . - If, it appears to the Chief Inspector of Factories that in any factory the provisions of breathing apparatus is necessary, he may, by order in writing require the occupier to provide suitable breathing apparatus in addition to the equipment for light trailer pump or large trailer pump as the case may be.]\n[66A. Buildings and Structures.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 122
    },
    "prev_section": "64",
    "next_section": "66B"
}