    "act_title": "The Punjab Factory Rules, 1952",
    "act_slug": "the-punjab-factory-rules-1952",
    "section_label": "Section",
    "section": {
        "number": "59",
        "title": "59. Belts, etc., to be regularly examined.",
        "chapter": null,
        "content": "60.\n[(1) Examination of Hoists and Lifts.\n(2) Exemption of certain Hoists and Lifts.\nSchedule\nI\nII\nClass or description of hoist or lift\nRequirements which shall not apply\nHoist or lifts mainly used for raising materials for charging\n\t\t\t\tblast furnaces or lime-kilns\nSub-section 1(b) in so far as it requires a gate at the bottom\n\t\t\t\tlanding sub-section (d), sub-section 1(e).\nHoist not connected with mechanical power and which are not\n\t\t\t\tused for carrying persons\nSub-section 1(b) in so far as it requires the hoist way or\n\t\t\t\tliftway enclosure to be so constructed as to prevent any person\n\t\t\t\tor thing from being trapped between any Part of the hoist or lift\n\t\t\t\tand any fixed structure or moving Part, sub-section 1(e).\n[60A. Lifting machine, chains, ropes and lifting tackles.\n(b) A table showing the safe working loads of every kind and size of chain, rope, or lifting tackle in use, and in the case of multiple sling, the safe working loads at different angles of the legs, shall be posted in the store room or place where or in which the chains, ropes or lifting tackles are kept, and in prominent position on the premises and no rope, chain or lifting tackle not shown in the table shall be used:\n(i) Name of occupier of factory.\n(ii) Address of the factory.\n(iii) Distinguishing number or marks, if any, and description sufficient to identify the lifting machine, chain, rope, or the lifting tackle.\n(iv) Date when the lifting machine, chain, rope or lifting tackle was first taken into use in the factory.\n(v) Date and number of the certificate relating to any test and examination made under sub-rules (1) and (7) together with the name and address of the person who issued the certificate.\n(vi) Date of each periodical thorough examination made under sub- clause (iii) of clause (a) of sub-section (1) of Section 29 of the Act and sub-rule (6) and by whom it was carried out.\n(vii) Date of annealing or other heat treatment of the chain and other lifting tackle made under sub-rule (5) and by whom it was carried out.\n(viii) Particulars of any defects affecting the safe working load found at any such thorough examination of after annealing and of the steps taken to remedy such defects.\n(b) The register shall be kept readily available for inspection.\n(i) All chain, slings, rings, hooks, shackles and swivels used in connection with molten metal or molten slag or when they are made of half inch bar or smaller, once at least in every six months.\n(ii) All other chins, rings, hooks, shackles and swivels in general use once at least in every twelve months :\n(i) Chains made of malleable cast iron.\n(ii) Plate link chains.\n(iii) Chains, rings, hooks, shackles and swivels made of steel or of any non-ferrous metal.\n(iv) Pitched chains, working on sprocket or packed wheels.\n(v) Rings, hooks, shackles and swivels permanently attached to pitched chain pulley blocks or weighing machines.\n(vi) Hooks and swivels having screw threader Parts or ball bearing or other case hardened Parts.\n(vii) Socket shackles secured to wire ropes by white metal capping.\n(viii) Bordeaux connections.\n[60B. Passageways for cranes.\n[61. Pressure Plant.\n(a) of good construction, sound material, adequate strength and free from any patent defect;\n(b) properly maintained in a safe condition;\n(c) fitted with -\n(i) a suitable safety valve or other effective device to ensure the maximum permissible working pressure of the vessel shall not be exceeded;\n(ii) a suitable pressure gauge easily visible and designed to show, at all times, the correct internal pressure in kilogram per square centimetre and marked with a prominent red mark at the safe working pressure of the vessel;\n(iii) a suitable stop valve or valves by which the vessel may be isolated from other vessels or source of supply of pressure; and\n(iv) a suitable drain cock or valve at the lowest Part of the vessel for the discharge of connected liquid;\n(d) thoroughly examined by a competent person -\n(i) externally, once in every period of six months, to ensure general condition of the vessel and the working of its fittings;\n(ii) internally, once in every period of twelve months, to ensure condition of the walls, seams and dies both inside and outside of the vessels, soundness of the Parts of the vessel, and the effects of corrosion. If by reason of construction of the vessel thorough internal examination is not possible, this examination may be replaced by a hydraulic test which shall be carried out once in every two years; provided that for the vessels in continuous processes which cannot be frequently opened, the period of internal examination may be extended to four years; and\n(iii) hydraulically tested at intervals of not more than four years; provided that in respect of pressure vessels with thin walls such as sizing cylinders made of copper or any other non-ferrous metal periodic hydraulic test may be dispensed with on the condition that the requirements laid down in clause (2) are fulfilled:\n(b) If no information as to the date of construction, thickness of walls and safe working pressure is available, the age of the sizing cylinder shall be determined by the competent person in consultation with the Chief Inspector from any other Particulars available with the manager.\n(c) Every new and second-hand cylinder of thin walls to which repairs, which may affect its safety have been carried out shall be tested before use at least one and a half times of its working pressure.\n(a) any vessel which comes within the scope of the Indian Boilers Act,\n(b) metal bottles of cylinder used for the storage or transport of compressed gases or liquified or dissolved gases under pressure.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 118
    },
    "prev_section": "58",
    "next_section": "62"
}