    "act_title": "The Orissa Factories Rules, 1950",
    "act_slug": "the-orissa-factories-rules-1950",
    "section_label": "Section",
    "section": {
        "number": "55J",
        "title": "55J. Stoppers on wheel track of travelling cranes.",
        "chapter": null,
        "content": "Rules prescribed under Sub-section (2) of Section 31\nRules prescribed under Sub-section (2) of Section 31\n[56. Pressure vessel or plants.\n(b) \"Maximum permissible working pressure\" is the maximum pressure at which a pressure vessel or plant is permitted to be operated or used under this rule and is determined by the technical requirements of the process;\n(c) \"Plant\" means a system of piping that is connected to a pressure vessel and is used to contain a gas, vapour or liquid under pressure greater than the atmospheric pressure and includes the pressure vessel:\n(d) \"Pressure vessel\" means [a] vessel that maybe used for containing, storing, distributing, transferring, distilling, processing or otherwise handling any gas, vapour or liquid under pressure greater than the atmospheric pressure and includes any pipeline fitting or other equipment attached thereto or used in connection herewith ; and\n(e) \"competent person\" means a person who is in the opinion of the Chief Inspector, capable by virtue of his qualifications, training and experience of conducting a thorough examination and pressure tests, as required, on a pressure vessel or plant, and of making a full report on its condition.\n(a) [* * *] ;\n(b) vessels having an internal operating pressure not exceeding 1 Kg. F/Cm. ( 15 lbs/sq.-in);\n(c) steam boilers, steam and feed pipes and their fittings coming under the purview of Indian Boilers Act, 1923 (V of 1923)\n(d) metal bottles or cylinders used for storage or transport of co-pressed gases or liquefied or dissolved gases under pressure covered by the Gas Cylinder Rules, 1940 framed under the Indian Explosives Act, 1884 (IV of 1884);\n(e) vessels in which internal pressure is due solely to the static head of liquid;\n(f) vessels in which a nominal water capacity not exceeding 500 litres connected in a water-pumping system containing air that is compressed to serve as a cushion;\n(g) vessels for nuclear energy application;\n(h) refrigeration plant having a capacity of 3 tons or less of refrigeration in 24 hours; and\n(i) working cylinders of steam engines or prime movers, feed pumps and stream traps, turbine cashings compressor cylinders; steam separators or dryers; steam strainers, steam de-super-heater, oil separators, air receivers for fire spinkler installations; air receivers of monotype machines @ provided the maximum working pressure of the air receiver does not exceed 1.33 Kg.f/cm.'2 (20 l bi/sq. inch) and the capacity 84.05 litres (3 cu ft.) air-receivers of electrical circuit breakers; air receivers of electrical relays air vessels on pumps, pipe coils, accessories of instruments and appliances, such as cylinders and piston assemblies used for operating relays and interlocking type of guards, vessels with liquids subjected to static head only and hydraulically operating cylinders other than any cylinder communicating with an air loaded accumulator.\n(a) shall be properly designed on sound engineering practice;\n(b) shall be of good construction, sound material, adequate strength and free from any patent defects; and\n(c) shall be properly maintained in a safe condition\n(a) a suitable safety valve or other effective pressure relieving device of adequate capacity to ensure that the maximum permissible working pressure of the pressure vessel shall not be exceeded. It is be met to operate at a pressure not exceeding the maximum permissible working pressure and when more than one protective device is provided, only one of the devices need be set to operate at the maximum permissible working pressure and the additional device shall be set to discharge at pressure not more than 5 per cent in excess of the maximum permissible working pressure;\n(b) a suitable pressure gauge with a dial range not less than 1.5 times the maximum permissible work in pressure, easily visible and designed to show at all times the correct internal pressure and marked with a prominent red mark at the maximum permissible working pressure of the pressure vessel;\n(c) a suitable nipple and globe valve connected for the exclusive purpose of attaching a test pressure gauge for checking the accuracy of the pressure gauge referred to in Clause (b) of this sub-rule;\n(d) a suitable stop valve or valves by which the pressure vessel may be isolated from other pressure vessels or plant or source of supply of pressure. Such a stop valve or valves shall be located as close to the pressure vessel as possible and shall be easily accessible; and\n(e) a suitable drain cock or valve at the lowest part of the pressure vessel for the discharge of the liquid or other substances that may collect in the pressure vessel.\n(b) To further protect the pressure vessel in the event of failure of the reducing value or device, at least one safety valve having a capacity sufficient to release all the steam, vapour or gas without undue pressure rise as determined by the pressure at the source of supply and size of the pipe connecting the source of supply, shall be fitted on the low pressure side of the reducing valve.\n(b) No pressure vessel or plant shall be used in a factory unless there has been obtained from the maker of the pressure vessel or plant or from the competent person a certificate specifying the design pressure or maximum permissible working pressure thereof and stating the nature of tests to which the pressure vessel or plant and its fittings (if any) have been subjected and every pressure vessel or plant so used in a factory shall be marked so as to enable it to be identified as to be the pressure vessel or plant to which the certificate shall be available for perusal by the Inspector.\n(c) No pressure vessel or plant shall be permitted to be operated or used at a pressure higher than its design pressure or maximum permissible working pressure as shown in the certificate.\n(a) externally, once in every period of six month ;\n(b) internally, once in every period of twelve months ; if by person of the construction of a pressure vessel or plant, a thorough internal examination is not possible, this examination may be replaced by a hydrostatic test which shall be carried out once in every period of two years :\n(c) hydrostatically tested once in every period of four years\n(b) If any information as to the date of construction, thickness of walls, or maximum permissible working pressure is not available, the age of such pressure vessel or plant shall be determined by the competent person in consultation with the Chief Inspector from the other particulars available with the matter.\n(c) Every new and second band vessel or plant of thin walls to which repairs likely to effect its strength or safety have been carried out shall be tested before use to at least 1.5 times its maximum permissible working pressure.\n(b) A report of the result of every examination or test carried out shall be completed in the prescribed Form No. 8 and shall be signed by the person making the examination or test, and shall he kept available for perusal by the Inspector at all hours when the factory or any part thereof is working.\n(c) When the report of any examination under this rule specified any < condition for securing the safe working of any pressure vessel or plant, the pressure vessel or plant shall not be used unless the specified condition is fulfilled.\n(d) The competent person making report of any examination under this rule, shall within seven days of the completion of the examination, send to the Inspector a copy of the report in every case where the maximum permissible working pressure is reduced or the examination shows that the pressure vessel or plant or any part thereof cannot continue to be used with safety unless certain repairs are carried out or unless any other safety measure is taken.\n(b) Certificate or reports of any examination, or test of any pressure vessel or plant to which Sub-rules 7 to 9 do not apply, conducted or required to be conducted under any other law in force and other relevant record relating to such pressure vessel or plant, shall be properly maintained as required under the said law and shall be produced on demand by the Inspector.]\n[56A. Water scaled Gasholder.\n(ii) A permanent register in prescribed Form 83 duly signed by the occupier or manager shall be maintained giving the following particulars:\n(a) The serial number of the gasholder, vide Sub-rule (3) above and the particulars of manufacturer, i.e., maker's name, date of manufacture, capacity, number of lifts, pressure thrown by holder, when full of gas;\n(b) The dates of inspection carried out as required under Rule 425 and by whom carried out;\n(c) The method of inspection used;\n(d) Date of painting etc.;\n(e) Nature of repairs and name of person carrying out repairs; and\n(f) Remarks.\n(iii) The results of examinations by a competent person carried out under Sub-rules (4) and (5) shall be in the prescribed Form No. 33.\nRules prescribed under Sub-section (2) of Section 34\nRules prescribed under Sub-section (2) of Section 34",
        "footnote": "",
        "is_definition": false,
        "sort_order": 58
    },
    "prev_section": "55",
    "next_section": "57"
}