    "act_title": "The Orissa Factories Rules, 1950",
    "act_slug": "the-orissa-factories-rules-1950",
    "section_label": "Section",
    "section": {
        "number": "18",
        "title": "18. When artificial humidification not allowed.",
        "chapter": null,
        "content": "(a) by the use of steam during any period when the dry-bulb temperature of that room exceeds 85 degrees;\n(b) at any time when the wet-bulb reading of the hygrometer is higher than specified in the following Schedule in relation to the drybulb reading of the hygrometer at that time ; or as regards it drybulb reading intermediate between any two dry-bulb readings indicated consecutively in the schedule when the dry-bulb reading does not exceed the wet-bulb reading to the extent indicated in relation to the lower of these two dry-bulb readings\nSchedule\nDry Bulb\nWet Bulb\nDry Bulb\nWet Bulb\nDry Bulb\nWet Bulb\n60.0\n58.0\n77.0\n75.0\n94.0\n86.0\n61.0\n59.0\n78.0\n76.0\n95.0\n87.0\n62.0\n60.0\n79.0\n77.0\n96.0\n87.5\n63.0\n61.0\n80.0\n78.0\n97.0\n88.0\n64.0\n62.0\n81.0\n79.0\n98.0\n88.5\n65.0\n63.0\n82.0\n80.0\n99.0\n89.0\n66.0\n64.0\n83.0\n80.5\n100.0\n89.5\n67.0\n65.0\n84.0\n81.0\n101.0\n90.0\n68.0\n66.0\n85.0\n82.0\n102.0\n90.0\n69.0\n67.0\n86.0\n82.5\n103.0\n90.5\n70.0\n68.0\n87.0\n83.0\n104.0\n90.5\n71.0\n469.0\n88.0\n83.5\n105.0\n91.0\n72.0\n70.0\n89.0\n84.0\n106.0\n91.0\n73.0\n71.0\n90.0\n84.5\n107.0\n91.5\n74.0\n72.0\n91.0\n85.0\n108.0\n91.5\n75.0\n73.0\n92.0\n85.5\n109.0\n92.0\n76.0\n74.0\n93.0\n86.0\n110.0\n92.0",
        "footnote": "",
        "is_definition": false,
        "sort_order": 23
    },
    "prev_section": "3",
    "next_section": "19"
}