    "section": {
        "number": "97",
        "title": "97. Precautions against fire.",
        "chapter": null,
        "content": "(a) its exhaust pipe shall be insulated or sufficiently cooled and the end of the exhaust pipe shall be directed away from the well head; and\n(b) its exhaust manifold shall be shielded to prevent its contact with liquid or gas which might otherwise fall on it.\n(a) provide with an air intake shut-off valve with readily accessible remote control arrangement where a diesel engine is located within thirty metre of a well;\n(b) provide with water bath treater, heater treater and flare line, a suitable device for remote ignition of burners; and\n(c) ensure to effectively earth all plant, machinery and derricks for dissipation of any static electric charge.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 96
    },