    "id": 12380,
    "slug": "the-merchant-shipping-crew-accommodation-rules-1960",
    "title": "The Merchant Shipping (Crew Accommodation) Rules, 1960",
    "short_title": "The Merchant Shipping (Crew Accommodation) Rules, 1960",
    "act_number": "Published vide Notification Gazette of India, 1960",
    "act_year": 1960,
    "act_type": "CENTRAL",
    "location": "India (Central)",
    "law_status": "unknown",
    "enactment_date": null,
    "description": "The Merchant Shipping (Crew Accommodation) Rules, 1960",
    "preamble": "",
    "section_label": "Section",
    "sections": [
        {
            "number": "1",
            "title": "1. Short title, Commencement and application.",
            "chapter": null,
            "content": "(a) every sea-going mechanically propelled ship of 200 tons gross and over for the time being registered in India, whether so registered before or after the date on which these rules come into force;\n(b) every such ship which, at any time after that date, is being constructed to the order of a person qualified to be the owner of an Indian Ship and has not been registered in India;",
            "footnote": "",
            "is_definition": false,
            "sort_order": 0
        },
        {
            "number": "2",
            "title": "2. Definitions.",
            "chapter": null,
            "content": "(a) \"Act\" means the Merchant Shipping Act, 1958\n(b) \"apprentice\" includes a cadet and a midshipman\n(c) \"approved\" means approved by the Central Government\n(d) \"chief officer\" includes a first Mate and at only Mate\n(e) \"crew\" means seamen and apprentices;\n(f) petty officer\"means a rating serving in a supervisory position or in a position of special responsibility who is classed as petty officer by collective agreement or custom;\n(g) \"rating\" means a member of the crew other than an officer;\n(h) \"sanitary accommodation\" means washing accommodation and accommodation containing water closets or urinals;\n(i) \"Schedule\" means a Schedule to these rules;\n(j) \"sleeping room\" does not include a hospital ward;\n(k) \"surveyor\" means a surveyor appointed under section 9 of the Act;\n(l) \"tons\" means gross tons;\n(m) trunked mechanical ventilation system\"means a system of ventilation complying with the specifications set forth in the First Schedule;\n(n) \"washing accommodation\" does not include \"\n(i) any sleeping room or hospital ward, whether or not provided with a wash basin, bath or shower;or\n(ii) any room appropriated for use only as a laundry.",
            "footnote": "",
            "is_definition": true,
            "sort_order": 1
        },
        {
            "number": "3",
            "title": "3. Plans.",
            "chapter": null,
            "content": "(a) plans of the proposed crew accommodation, on a scale not smaller than 1 in 50 in the case of a ship under [153 meters] in length and not smaller than 1 in 100 in the case of any other ship, showing clearly the purpose for which each space therein is to be appropriated and the proposed disposition of the furnishing, fittings and obstructions therein;and\n(b) plans showing clearly the proposed arrangements for supplying water to the crew accommodation and for heating, lighting and ventilating the accommodation.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 2
        },
        {
            "number": "4",
            "title": "4. Position of Crew Accommodation.",
            "chapter": null,
            "content": "(a) any passenger ship;\n(b) any tug;\n(c) any cable ship;\n(d) any salvage ship;\n(e) any crane ship;\n(f) any dredger and any ship engaged in the conveyance of the spoil of dredging;\n(g) any other ship not being a ship engaged in the carriage of cargo, if it is satisfied that compliance with such requirement is unreasonable or impracticable by reason of the size or intended service of the ship.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 3
        },
        {
            "number": "5",
            "title": "5. Height of Crew Accommodation.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 4
        },
        {
            "number": "6",
            "title": "6. Construction of Bulkheads and Panelling.",
            "chapter": null,
            "content": "(a) a permanent coal bunker;\n(b) an oil fuel bunker;\n(c) a cargo or machinery space;\n(d) a lamp room or paint room;\n(e) a store room not forming part of the crew accommodation (other than a dry provision store room);\n(f) a chain locker;or\n(g) a cofferdam;\n(a) a sanitary accommodation from another sanitary accommodation :\n(b) a laundry or drying room from anther laundry or drying room;\n(c) a cold store room form another cold store room;\n(d) a galley from another galley or a pantry;\n(e) sanitary accommodation appropriated for the sole use of one person from a sleeping room form which it may be directly entered.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 5
        },
        {
            "number": "7",
            "title": "7. Overhead Decks.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 6
        },
        {
            "number": "8",
            "title": "8. Flooring.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 7
        },
        {
            "number": "9",
            "title": "9. Protection from Weather, etc.",
            "chapter": null,
            "content": "(a) the protection of the crew against injury to the greatest practicable extent;\n(b) the protection of the crew accommodation against the weather and the sea;\n(c) the insulation of the crew accommodation from heat and cold;\n(d) the protection of the crew accommodation against moisture due to condensation;\n(e) the exclusion from the crew accommodation of effluvia originating in other spaces in the ship; and\n(f) the exclusion from the crew accommodation, to the greatest practicable extent, of noise originating in other spaces in the ship.\n(a) Every opening from an open deck into the crew accommodation shall be protected against the weather and the sea.\n(b) The crew accommodation shall be accessible at all times from the open deck.\n(c) Access to sleeping rooms, mess rooms, recreation rooms and studies forming part of the crew accommodation shall be obtained from a passageway which shall be provided with a hinged door at any entrances from the open deck.\n(d) Bow hawse pipes shall not be situated in the crew accommodation. The Central Government may exempt any ship of under 400 tons from the requirement of this clause.\n(e) Stem supply and exhaust pipes for steering gear, winches and similar equipment shall not pass through crew accommodation. Provided that, if in the case of nay ship of 500 tons or over the Central Government is satisfied that alternative arrangements are unreasonable or impracticable in the circumstances, it may permit such pipes if properly encased to pass through passageways forming part of the crew accommodation subject, in the case of supply pipes, to the following conditions :-\n(i) the pipes shall be constructed of solid drawn steel or other suitable material; (ii) the pips shall be of a scantling sufficient to withstand the maximum pressure form the ship's boiler system; (iii) all connections in the pipes shall be by faced flange properly joined;and (iv) the pipes shall be fitted with adequate drainage arrangements. The Central Government may exempt any ship of under 500 tons from the requirements of this clause if it is satisfied that adequate arrangements have been made to ensure the safety of the crew.\n(ii) the pips shall be of a scantling sufficient to withstand the maximum pressure form the ship's boiler system;\n(iii) all connections in the pipes shall be by faced flange properly joined;and\n(iv) the pipes shall be fitted with adequate drainage arrangements.\n(f) All steam pipes, hot water pipers and calorifiers in or serving the crew accommodation shall be efficiently lagged wherever lagging is necessary for the conservation of heat or the protection of the crew against injury or discomforts. All cold water pipes in the crew accommodation shall be efficiently lagged wherever lagging is necessary for the prevention of condensation.\n(g) Chain pipes, and ventilator trunks to cargo spaces or tanks shall be made of steel or other suitable material and shall be gastight where they pass through any part of the crew accommodation.\n(h) Batteries for the operation of the ships radio installation, if any shall not be placed in any sleeping room provided for the crew, and precautions shall be taken which will ensure that fumes from such batteries cannot discharge into any part of the crew accommodation.\n(i) The bulkheads and the pars of the ship's side which enclose the crew accommodation shall be insulated in a manner which will prevent overheating of the accommodation, and shall be covered with protective covering which will prevent the condensation of moisture. The Central Government may exempt any ship form the requirements of this clause to the extent that it is satisfied that the crew accommodation is adequately protected by its position and ventilation against overheating and condensation.\n(j) Every bulkhead, casing and deck separating the crew accommodation from other spaces in the ship in which heat or cold may be generated shall be insulated in a manner which will prevent the crew accommodation being so affected by such heat or cold or by condensation as to prejudice the health or comfort of the crew.\n(k) Every ship for the time being regularly engaged voyages in the Tropics or the Persian Gulf shall be provided with awnings which will cover:\n(i) all exposed decks and house-tops situated immediately above any part of the crew accommodation :\n(ii) all exposed sides of galleys situated on an open deck;\n(iii) such portion of the deck spaces provided for the recreation of the crew in compliance with sub-rule (6) of rule 21 as will provide a shaded area adequate in extent having regard to the number of persons in the crew and to any shade provided for such spaces by overhanging decks.\n(l) There shall be no direct opening between the crew accommodation (other than recreation deck spaces) and any space used as a store room for engine room stores or deck department stores. The Central Government may exempt any ship of under 500 tons form the requirement of this clause to the extent that it is satisfied that compliance therewith is impractical in the circumstances.\n(m) There shall be no direct opening between the crew accommodation (other than recreation deck spaces) and spaces used as :-\n(i) permanent coal bunkers;\n(ii) oil fuel bunkers;\n(iii) cargo or machinery spaces;\n(iv) lamp rooms or paint rooms;\n(v) store rooms not forming part of the crew accommodation (other than store rooms or engine room or deck department stores);\n(vi) chain lockers;or\n(vii) Cofferdams Provided that there may be a direct opening between machinery spaces and sanitary accommodation and changing room provided for the sole use of offices and ratings of the engine room department.\n(n) Subject to the provisions of sub-rule (3) of rule 23, sub-rule (6) of rule 27 and sub-rule (16) of rule 31 there shall be no direct opening between the crew accommodation (other than recreation deck spaces or passageways) and any sanitary accommodation, laundry or drying room (whether or not such sanitary accommodation) Provided that nothing in this clause shall prohibit direct openings between spaces forming part of sanitary accommodation, or between spaces appropriated for use as laundries or drying rooms.\n(o) Any part of the crew accommodation which is adjacent to any part (other than the crown) of a tank in which oil may be carried in bulk, shall be separated therefrom by a gastight steel division additional to the division which retains the oil. The Central Government may exempt any ship from the requirement of this clause if it is satisfied that the division which retains the oil is likely to remain oil tight under service conditions.\n(p) If any part of the crew accommodation is situated on a deck which forms the crown of a space in which oil may be carried in bulk, such deck shall be oil tight. No manholes or other openings to the oil tanks shall be situated in the crew accommodation.\n(q) If any part of the crew accommodation is situated on a deck forming the crown of a permanent coal bunker, such deck shall be gastight.\n(r)The means of access to and egress from every part of the crew accommodation shall be so situated that in the event of fire in any lamp room or paint room in the ship, access to and egress from the crew accommodation will not be impeded.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 8
        },
        {
            "number": "10",
            "title": "10. Heating.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 9
        },
        {
            "number": "11",
            "title": "11. Lighting.",
            "chapter": null,
            "content": "(b) The electric lighting of the spaces referred to in clauses (d) to (n) (both inclusive) shall be deemed to be adequate for the purposes of these rules, if when the lamp and paintwork are new, the illumination in the horizontal plane when measured at the points and in the manner prescribed in clause (c) is steady and object to a tolerance of 10 percent is maintained at a value not less than that prescribed for every such space.\n(c) The points at which illumination shall be measured shall be as follows :-\n(i) where a general measurement points are prescribed for the illumination of a space, then measurements shall be taken at every point midway between every 2 adjacent lamps and at every point midway between every lamp and any position on any boundary of this space. Provided always that where within any space a part of that space (being a part of that space available for fee movement) is shaded from the direct rays of a lamp by a re-entrant angle formed in the boundary of the space, then the central point of the part of space so shaded shall also be general measurement point; and\n(ii) where particular measurement points are also prescribed for a space, then measurements shall in addition be taken at every such point.\n(d) Sleeping Rooms and Day Rooms -\n(e) Mess Rooms--\n(f) Recreation and smoking Rooms-\n(g) Hospital Wards --\n(h) Offices and Studies -\n(i) Sanitary Accommodation (including sanitary accommodation in hospitals) \"\n(j) Laundries-\n(k) Drying Rooms -\n(l) Galleys (including Bakeries and Pantries)-\n(m) Provision Store Rooms--\n(n) Passageways, Companionways and covered Recreation Deck Spaces-",
            "footnote": "",
            "is_definition": false,
            "sort_order": 10
        },
        {
            "number": "12",
            "title": "12. Ventilation.",
            "chapter": null,
            "content": "(b) The sectional area of every part of the inlet and exhaust system (other than a par serving a drying room or locker) shall be at least [38.71 square centimetre] for each person for whose use at any one time the space is appropriated and shall not be less than [122.58 square centimetres] in all at any point in the system. The effective area of the inlet and exhaust system serving each space shall be capable of being adjusted from fully open down to a minimum of the [19.35 square centimetres] for each person likely to use the space at any time.\n(a) maintain the air at a satisfactory temperature and relative humidity as compared to outside air conditions;\n(b)ensure a sufficiency of air charges in all air conditioned spaces;and\n(c) take into account particular characteristics of operations at sea so as to avoid producing objectionable noises or vibrations.]",
            "footnote": "",
            "is_definition": false,
            "sort_order": 11
        },
        {
            "number": "13",
            "title": "13. Drainage.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 12
        },
        {
            "number": "14",
            "title": "14. Painting etc.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 13
        },
        {
            "number": "15",
            "title": "15. Marking.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 14
        },
        {
            "number": "16",
            "title": "16. Sleeping Rooms.",
            "chapter": null,
            "content": "(i) Offices.\n(ii) Petty Officers.\n(iii) Apprentices.\n(iv) Ratings of the deck department other than petty officers.\n(v) Ratings of the engine room department other than petty offices.\n(vi) Ratings of catering department other than petty offices.\n(b) Every watch of ratings shall be provided with sleeping rooms separate from those of other watches. Day men shall be provided with sleeping rooms separate from those of watch keepers.\n(a) Officers in charge of a department, navigating and engineer officers in charge of a watch and first or only radio officers-1 person per room.\n(b) Other Officers. - Wherever practicable 1 person per room and in no event, more than 2 persons per room.\n(c) Apprentices. - Wherever practicable not more than 3 persons per room and in no event, more than 4 persons per room.\n(d) Chief or only steward and chief or only cook, in either case n a ship of 3, 000 tons or over regularly employed otherwise than as home trade ship \"1 person per room.\n(e) Petty Officers not being persons referred to in clause (d). - Wherever practicable, 1 person per room and in no even, more than 2 persons per room.\n[(f) Other ratings. - Not more than 3 persons per room in a cargo ship and not more than 6 persons per room in a passenger ship;\nAccommodating\n\t\t\t\ton rating\nAccommodating\n\t\t\t\ton rating\nFor\n\t\t\t\ta room Accommodating\nFor\n\t\t\t\ta room Accommodating\n(i)In\n\t\t\t\tship other than passenger ships of 1,000 tons or over but less\n\t\t\t\tthan 3,000 tons...........................\n2.75\n\t\t\t\tsq. meters\n2.75\n\t\t\t\tsq. meters\n(ii)In\n\t\t\t\tships other than passenger ships of 3,000 tons or over but less\n\t\t\t\tthan 10,000 tons................\n3.75\n\t\t\t\tsq. meters\n2.75\n\t\t\t\tsq. meters\n(iii)\n\t\t\t\tIn ships other than passenger ships of 10,000 tons or over but\n\t\t\t\tless than 20,000 tons..................................\n4.25\n\t\t\t\tsq. meters\n3.25\n\t\t\t\tsq. meters\n(iv)\n\t\t\t\tIn ships other than passenger ships of 20,000 tons or\n\t\t\t\tover.............\n4.75\n\t\t\t\tsq. meters\n3.75\n\t\t\t\tsq, meters\n(v)\n\t\t\t\tIn passenger ships of 1,000 tons or over but less than 3,000\n\t\t\t\ttons...............\n----\n2.0\n\t\t\t\tsq. meters\n(vi)\n\t\t\t\tIn passenger ships of 3,000 tons or over but less than 10,000\n\t\t\t\ttons..........................\n----\n2.75\n\t\t\t\tsq. meters\n(viii)\n\t\t\t\tIn passenger ships of 10,000 tons or over\n\t\t\t\t….......................\n30.25\n\t\t\t\tsq. meters\n2.75\n\t\t\t\tsq. meters\n(b) Subject to the provision of clause (c), in every ship to which these rules apply, if private sitting rooms or day rooms are not provided, the per head floor area of a sleeping room for an officer shall be as follows :\n(i)In\n\t\t\t\tships of 1,000 tons or over but less than 3,000\n\t\t\t\ttons.....................\n4.25\n\t\t\t\tsq. meters\n(ii)\n\t\t\t\tIn ships of 3,000 tons or over but less than 10,000\n\t\t\t\ttons.........................................\n6.50\n\t\t\t\tsq. meters\n(iii)\n\t\t\t\tIn ships of 10,000 tons or\n\t\t\t\tover..........................................\n7.50\n\t\t\t\tsq. meters\n(c) In every ship of 3000 tons or over, there shall, as far as practicable, be provided an adjoining sitting room or a day room in addition to the sleeping room for the Chief and Second Engineer. Officer and the Chief Navigating Officer.\n(d) In determining floor area of a room for the purpose of this sub-rule, spaces occupied by berths, lockers, seats or chests of drawers shall be taken into account but any spaces which by reasons of their small size or irregular shape cannot accommodate furniture and do not contribute to the area available for free movement shall not be taken into account.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 15
        },
        {
            "number": "17",
            "title": "17. Beds.",
            "chapter": null,
            "content": "(a) within 10.2 centimetres of ventilation trunk which may be used for circulating hot air; or\n(b) within 5.10 centimetres of a bulkhead of the ship's side unless the bed is so supported and the room so constructed as to avoid harbouring dirt and vermin in or near the bed, to enable the bedding to be kept clean and dry and to minimise the soiling of paintwork in way of the bed; or\n(c) below any joint in an overhead water pipe or sanitary discharge.]\n(b) The upper bed in a double tier shall be at least 76.20 centimetres below the lower side of the deck head beams or other obstructions measured from the bottom of the matters.\n(c) The Central Government may exempt;\n(i) any ship under 500 tons from any of the requirements of this sub-rules;\n(ii) any ship from the requirements of clause (b) of the sub-rule to the extent that it is satisfied that it is unreasonable or impracticable in the circumstances to remove obstructions above the beds in the crew accommodation of that ship.\n(b) The minimum size of beds provided in a ship of 3000 tons or over for the Chief Navigating Officer and Chief and Second Engineers shall be atleast 2000 millimetres by 900 millimetres in a passenger ship and atleast 2000 millimetres by 1100 millimetres in any other ship, the measurement in each case being taken inside the lee boards or lee rails, if any, at right angles to each other.]",
            "footnote": "",
            "is_definition": false,
            "sort_order": 16
        },
        {
            "number": "18",
            "title": "18. Furniture and fittings in sleeping rooms.",
            "chapter": null,
            "content": "(a) for each person accommodated in the room :-\n(i) One drawer having a capacity of at least 0.056 cubic meters;\n(ii) One clothes locker or wardrobe, in either case at least 1.68 meters in height and 2032.25 sq. centimetres in internal area; the locker or wardrobe shall be fitted with a shelf not less than 23 centimetres and not more than 38.10 centimetres below its top and with fittings on which the clothes may be hung; (iii) At least one coat hook in addition to any coat hooks fitted in a locker or wardrobe; (b) A table of fixed or drop leaf type or a desk, or a sliding leaf or top fitted to a chest of drawers; (c) Comfortable seats sufficient to accommodate at one time all the persons accommodated in the room. Such seats shall be provided in addition to the beds in the room. The Central Government may exempt any passenger ship from the requirements of this clause to the extent that it is satisfied that a lesser number of seats in adequate in the circumstances; (d) A mirror suitable for toilet purposes; (e) A cabinet suitable for containing toilet requisites; (f) A book rack; (g) A runner of jute, coir or other suitable material at one side of each be or tier of beds, as the case may be; (h) A curtain fitted to each bed, unless the room accommodates only one person; and (i) A curtain fitted to each side scuttle, unless the side scuttle is fitted with blinds or jalousies. (2) Sub-rule (1) shall apply to sleeping rooms for petty officers at it applies to sleeping rooms for other ratings, subject to the following modifications and additions :-\n(iii) At least one coat hook in addition to any coat hooks fitted in a locker or wardrobe;\n(b) A table of fixed or drop leaf type or a desk, or a sliding leaf or top fitted to a chest of drawers;\n(c) Comfortable seats sufficient to accommodate at one time all the persons accommodated in the room. Such seats shall be provided in addition to the beds in the room. The Central Government may exempt any passenger ship from the requirements of this clause to the extent that it is satisfied that a lesser number of seats in adequate in the circumstances;\n(d) A mirror suitable for toilet purposes;\n(e) A cabinet suitable for containing toilet requisites;\n(f) A book rack;\n(g) A runner of jute, coir or other suitable material at one side of each be or tier of beds, as the case may be;\n(h) A curtain fitted to each bed, unless the room accommodates only one person; and\n(i) A curtain fitted to each side scuttle, unless the side scuttle is fitted with blinds or jalousies.\n(a) For each person accommodated in the room a second drawer having a capacity of at least 0.056 cubic meters shall be provided in addition to the drawer referred to in clause (a) of sub-rule (1).\n(b)The clothes, lockers or wardrobes provided shall be made of hardwood.\n(c) Each room shall be provided with :-\n(i) a rack suitable for holding :-\n(a) one drinking water bottle; and\n(b) one tumbler for each person accommodated in the rooms.\n(ii) a wash basin of vitreous china or other equally hygienic and durable material, which shall be fitted with an efficient and hygienic discharge overside or to an enclosed tank with a suction pipe served by a mechanically operated pump provided that a wash-basin shall not be required to be fitted in a sleeping room for petty officers if washing accommodation is readily accessible from the sleeping room.\n(a) For each officer accommodated n the room--\n(i) at least three drawers with a total capacity of 0.28 cubic metres or as near thereto as is practicable in the circumstances;\n(ii) a wardrobe at least 1.68 metres in height and 2967.74 sq. centimetres in internal sectional area:\n(iii) at least two coat hooks, in addition to any coast hooks fitted in the wardrobe;\n(b)A writing desk fitted, if practicable, with drawers additional to the aforesaid drawers.\n(c) A chair with arm rests;\n(d) A settee at least 1.83 metres in length or as near thereto as may be practicable in the circumstances, provided that the Central Government may permit the settee to be dispensed with-\n(i)if it is satisfied that a settee of adequate dimensions cannot be placed in the room without interfering with the comfort of the occupants; or\n(ii) in the case of a room which accommodates only one officer, if the Central Government has consulted such organizations as appears to it to be representative of the class of officer concerned and is satisfied that a fully upholstered easy chair with closed arms is provided in the room;\n(e) A mirror suitable for toilet purposes;\n(f) A cabinet suitable for containing toilet requisites;\n(g) A rack suitable for holding \"\n(i) one drinking water bottle, and\n(ii) one tumbler for each officer accommodated in the room.\n(h) A wash-basin of vitreous china or other equally hygienic and durable material, which shall be fitted with an efficient and hygienic discharge or to an enclosed tank with a suction pipe served by a mechanically operated pump; provided that a wash basin shall not be required to be fitted in a sleeping room if washing accommodation is readily accessible therefrom;\n(i) A splash plate or other means of protection for the wall above the was basin, if any;\n(j) A carpet runner of wool or similar material;\n(k) Curtains fitted to each bed, unless t he room accommodates only one officer;\n(l) Curtains fitted to each side scuttle, unless the side scuttle is fitted with blinds or jalousies;\n(m) A book case n any room which accommodates a Chief officer, Chief Engineer or Second Engineer, or in the case of a passenger ship a First Radio Officer: and\n(n) A book case or book rack in rooms which accommodate other officer.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 17
        },
        {
            "number": "19",
            "title": "19. Mess Rooms.",
            "chapter": null,
            "content": "(a) for Officers : one square metre per person\n(b) for crew : 0.7 square metre per person]\n(a)petty officers of the deck department;\n(b)petty officers of the engine room department;\n(c)other ratings of the deck department:;\n(d)other ratings of the engine room department.\n(i) for petty officers of the deck and engine room departments;\n(ii) for petty officers and other ratings of the same departments;\n(iii) for all ratings (other than petty officers) of the deck and engine room department.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 18
        },
        {
            "number": "20",
            "title": "20. Furniture and Fittings in Mess Rooms.",
            "chapter": null,
            "content": "(a) a storage locker or rack in either case capable of holding sufficient mess utensils for those persons, or\n(b) a storage locker at least [38.10 centimetres] by [38.10 centimetres] by [38.5 centimetres] in size for each of those persons.\n(a) any ship of under 1,000 tons from the requirement of a hot-press;\n(b) any ship of under 500 tons from any of the requirements of this sub-rule.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 19
        },
        {
            "number": "21",
            "title": "21. Recreation Spaces and Studies.",
            "chapter": null,
            "content": "(i) arrangement for showing films or television in a smoking room, library room or a mess room properly equipped for the purposes;\n(ii) a hobby-cum-games;room\n(iii) a swimming pool :",
            "footnote": "",
            "is_definition": false,
            "sort_order": 20
        },
        {
            "number": "22",
            "title": "22. Office Accommodation.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 21
        },
        {
            "number": "23",
            "title": "23. Washing Accommodation.",
            "chapter": null,
            "content": "(a) officers and apprentices;\n(b) petty offices;\n(c) ratings other than petty officers.\n(i) located outside the machinery space but with easy access to it; and\n(ii) fitted with individual clothes lockers as well as with tubs of shower baths an wash basins having hot and cold running fresh water.]\n(a) a passenger ship engaged solely on voyages which are normally of less than 24 hours durations : or\n(b) a cargo ship in which the number of members of crew are more than 100, render full compliance of this requirement unreasonable or impracticable exempt such ship from the requirement in full or to such extent as it deems necessary.\n(i) a bath and a shower combined shall be deemed as a bath only;\n(ii) in determining the required number of baths or showers or wash basins no account shall be taken of any private baths or showers or wash basins provided in pursuance of these rule or of persons for whose use such baths or showers or wash basins are provided:\n(iii) a bath, shower or wash basin shall be deemed to be private if it is appropriate for the exclusive use of not more than four persons.]",
            "footnote": "",
            "is_definition": false,
            "sort_order": 22
        },
        {
            "number": "24",
            "title": "24. Supply of water to washing accommodation.",
            "chapter": null,
            "content": "(a) in the case of a bath and shower combined, hot and cold fresh water shall be required to be laid on only to the bath or the shower; and\n(b) hot and cold fresh water shall not be required to be laid on to wash-basins provided for the sole use of ratings if it is laid on to spring-loaded draw-off taps in the same room in accordance with sub-rule (9) of rule 23.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 23
        },
        {
            "number": "25",
            "title": "25. Supply of Drinking Water.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 24
        },
        {
            "number": "26",
            "title": "26. Laundry Facilities, etc.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 25
        },
        {
            "number": "27",
            "title": "27. Water Closets.",
            "chapter": null,
            "content": "(a) officers and apprentice;\n(b) petty officers;\n(c) ratings, other than petty officers\nExplanation.\n(i) in determining the number of water closets no account shall be taken of any private water closet or the persons for whose use such private water closet is appropriated;\n(ii) a water closet shall deemed to be private if it is appropriated for the exclusive use of not more than four persons;\n(b) In addition to the water closets required by clause (a) three shall be provided such number of water closets, if any, as is required to increase the total number of water closets provided for the crew to the following scale :-\n(c) In determining the number of water closets required by this sub-rule no account shall be taken of any water closet forming part of a permanent hospital.\n(b) In every such ship, there shall also be provided a water closet and a wash basin having hot and cold running fresh water, within easy access of machinery spaces if such water closet is not fitted near engine room control center.\n(a) another water closet,\n(b) a urinal, or\n(c) washing accommodation if the water closet is served by a trunked mechanical ventilation system which effectively removes odours therefrom.\n(a) a water closet pedestal of single type with-\n(i) a pan of white vitreous china or other suitable material;\n(ii) a seat of polished hardwood or other suitable material with an opening of 10.2 centimetres at the front;\n(iii) a trap with a metal inspection plate; and\n(iv) an efficient ventilator connected to the out let;\n(b) an adequate flush of water, which shall be always available and supplied through self-closing non-concussive supply valves with a portable seating in metal which is not likely to become corroded;\n(c) a soil pipe not less than 10.2 centimetres in diameter so constructed as to facilitate cleaning and minimize the risk of obstruction;the pipe shall have a direct overboard outfall fitted with a strom-valve, unless sit is connected with a main sewage outfall by an efficient and hygienic system;\n(d) a device for holding toilet paper;\n(e) a hand rail or grip.\n(a) Each battery of water closets may consist of any number of separate compartments contained in properly constructed steel house with a minimum height of 1.98 metres from top of foot holds to the under side of beams.\n(b) The separate compartments in each battery shall be not less than 1.14 metres in length by 91.44 centimetres in width. Each such compartment shall have a separate entry fitted with a door with two shutters opening inwards which can be secured from the inside. The door need not extend to the full height of the compartment, but it shall not be less than 1.37 metres in height and 61.00 centimetres in width and the vertical height of the opening at the bottom shall not exceed 10.2 centimetres. The divisional bulk-heads between the compartments should extend to a height of within 30.5 centimetres should extend to a height of within 30.5 centimetres of the deck overhead and may also be opened at the bottom to the same extent and should be fitted with suitable hand grips. There shall be an enclosed passageway leading to the compartments of not less than 76.20 centimetres in breadth.\n(c) Where convenient the floor of the compartment shall be raised to a height level with the top of the pan by means of a filling of cement or other similar material, or any other equivalent arrangement. If this method is adopted, the floor shall have al light declivity on all sides running down towards the pan.\n(d) Every compartment shall be properly ventilated to the satisfaction of the surveyor by means of ventilators of such openings as will not interfere with privacy.\n(e) Adequate lighting, either natural or electric, shall be provided to the satisfaction of the Surveyor, at all times during day and light.\n(f) The pans shall preferably be made of white vitreous china or other suitable material. They shall be of an approved pattern complete with foot holds designed to prevent shipping. The orifice at the top of the pan shall be not less than 41.85 centimetres in length and not less than 23 centimetres in width. The pan shall be placed as low as practicable.\n(g) An arrangement which automatically flushes the pan at intervals not exceeding 5 minutes and a continuous trickle of water.\n(h) A soil pipe such as is referred to in clause (e) of sub-rule 9) provided with a metal inspection plate and sufficient ventilation.\n(i) Each battery shall be provided with a tank to supply fresh water from the service stands for ablution purposes.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 26
        },
        {
            "number": "28",
            "title": "28. Galleys.",
            "chapter": null,
            "content": "(a) any ship of under 1,000 tons;\n(b) any other ship, if the Central Government is satisfied that the galley is so situated that galley is so situated that the fumes therefrom can discharge only into the open air.\n(a) Every galley shall be provide with one or more cooking appliances with:-\n(i) a total oven capacity, suitable for roasting and baking of a least [7078.7 cubic centimetres] , and\n(ii) an area of range top-plat or boiling table, amounting to at least [309.68 square centimetres] for each person whom the galley is intended to serve. The Central Governments my exempt any ship from any of the requirements of this sub-clause in so far as they relate to cooking appliances in galleys intended to serve more than 60 persons, or to the area of any top-plate or boiling table in which electricity or heat-storage is employed or to the area of any appliance which the Central Government is satisfied is of unusual design;\n(b) Every galley shall be provided with at least the number of ovens and fire-grates specified in the following table :-\nNumbers\n\t\t\t\tof persons whom the galley in intended to serve\nNumbers\n\t\t\t\tof persons whom the galley in intended to serve\nNumber\n\t\t\t\tof ovens\nNumber\n\t\t\t\tof ovens\nNumbers\n\t\t\t\tof fire-grates\nNumbers\n\t\t\t\tof fire-grates\nNot\n\t\t\t\tmore than 20\n1\n1\nMore\n\t\t\t\tthan 20, but not more than 30\n2\n1\nMore\n\t\t\t\tthan 30, but not more than 60\n5\n2\nMore\n\t\t\t\tthan 60\n3\n2\n(c) The top plate of every cooking range shall be at a height which will enable it to be conveniently used by a person of normal height standing on the floor of the galley, unless a separate boiling table is provided at a such height.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 27
        },
        {
            "number": "29",
            "title": "29. Dry Provision Rooms.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 28
        },
        {
            "number": "30",
            "title": "30. Cold store rooms and Refrigerating Equipment.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 29
        },
        {
            "number": "31",
            "title": "31. Hospitals.",
            "chapter": null,
            "content": "(a) any ship of under 1,000 tons;\n(b) any other ship, if it is satisfied that the permanent hospital therein is fully air-conditioned or served by a trunked mechanical ventilation system.\n(i) which does not attract the provisions of rule 12A;\n(ii) the keel of which was laid or which was at a similar stage of construction on the 1st day of January, 1967; and\n(iii) which is intended to be employed, whether permanent or temporarily, on voyages to, from or within Persian Gulf area--\n(a) a locker approximately 30.48 centimetres square by 61.00 centimetres high, and fitted with a flat top and a flat top and a shelf;\n(b) a water bottle; and\n(c) a tumble.\n(a) seats adequate in number, having regard to the number of beds in the ward:\n(b) a clothes locker additional to that required by sub-rule (13) and complying with the specifications set forth in clause (a) (ii) of sub-rule (1) of rule 18;\n(c) a box cover which will conceal a bed-pan; and\n(d) electric bell pushes so arranged as to be within reach of each bed and communicating with the sleeping room of a person in charge of the patients.\n(b) The water closet pedestal shall be fitted either in a water closet or in washing accommodation forming part of the hospital.\n(c) Access to the water closet pedestal (or washing accommodation, as the case may be) shall be obtained directly from the hospital ward or from a lobby forming part of the hospital. The Central Government may exempt any ship from the requirement of this clause if it is satisfied that compliance therewith is impracticable in the circumstances, and that the water closet forming part of the hospital is situated sufficiently near to the ward.\n(d) The room in which the water closet pedestal is installed shall be provided with a gastight self-closing door unless it is served by a mechanical system of exhaust ventilation, and shall be so constructed as to facilitate cleaning and not to harbour dirt or vermin.\n(e) Such room shall be ventilated in the manner specified in sub-rule (7) of rule 27 and shall comply with the requirements of sub-rule (9) or (10) of the said rule whichever shall be applicable in the circumstances.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 30
        },
        {
            "number": "32",
            "title": "32. Medical Cabinet.",
            "chapter": null,
            "content": "(a) an outer door fitted with an efficient lock;\n(b) an inner cupboard fitted with a door and lock which shall be incapable of being opened by the key to the lock referred to in clause (a) of this sub-rule; such inner cupboard shall be used solely for the storage of poisonous drugs;\n(c) shelves so constructed as to facilitate the identification of medicines stored thereon.\n(d) A dispensing counter or dispensing table; in either case, with a surface which can easily be kept clean;\n(e) at teat tow drawers suitable for the storage of medical stores and used solely for that purpose;\n(f) fittings which will enable hot water bottles to be carried in a hanging position\n(g) a rack suitable for holding devices for measuring medicines;\n(h) a book containing readily understandable instructions for the use of medicines and medical stores provided for the crew, unless the ship carries a duly qualified medical practitioner as a member of the crew.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 31
        },
        {
            "number": "33",
            "title": "33. Protection from Mosquitoes.",
            "chapter": null,
            "content": "(a) Ports between 200 South latitude on the coasts of ---\n(i) Africa, excluding port Sudan and Massawa :\n(ii) Asia, excluding the East Indian Archipelago and the Philippine Island, but excluding Aden, Bombay, Madras, Vizagapatmam, Colombo, Trincomalee, Singapore, Penang and Port Swettenham:\n(b) Ports on the coasts of Madagascar.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 32
        },
        {
            "number": "34",
            "title": "34. Maintenance and Inspection of Crew Accommodation.",
            "chapter": null,
            "content": "(a) the time and date of the inspection;\n(b) the names and ranks of the persons making the inspection :\n(c) particulars of any respect in which the crew accommodation or any part thereof was found by any of the persons making the inspection not to comply with these rules.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 33
        },
        {
            "number": "35",
            "title": "35. Inspection by a Surveyor.",
            "chapter": null,
            "content": "(a) the ship is registered or re-registered in India :\n(b) any part of the crew accommodation in the ship undergoes substantial alterations or repairs\n(c) the number of persons accommodated in any sleeping room is increased above that marked in accordance with sub-rule (1) of rule 15;\n(d) in the opinion of a surveyor, there is reason to believe (whether or not in consequence of a complaint) that any of the provisions of these rules has been contravened in respect of that ship, or that nay condition subject to which the Central Government has exempted the ship from a requirement of these rules has not been satisfied:\n(e) a request for an inspection of the crew accommodation has been made to the Central Government to a competent authority by or on behalf of the owner of the ship or of any organization which appears to the Central Government to be most representative of the owners of Indian ships or of the semen concerned : or\n(f) a complaint has been lodged with an officer duly authorized under section 176 of the Act and complies with the following requirements:-\n(i) the complaint shall be in writing, signed by the Master or three or more members of the crew;\n(ii) the complaint shall specify the respects in which it is alleged that the crew-accommodation in the ship does not comply with these rules:\n(iii) the complaint shall be lodged without undue delay;\n(iv) the complaint shall be lodged at least 24 hours before the ship is due to sail, unless the ship is in port for less than 24 hours.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 34
        },
        {
            "number": "36",
            "title": "36. Fees.",
            "chapter": null,
            "content": "(a) when the ship is registered, re-registered or re-measured or\n(b) in pursuance of clause (f) of rule 35, if the Central Government is satisfied that the inspection was made in consequence of an unjustified complaint.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 35
        },
        {
            "number": "37",
            "title": "37. Accommodation shard with Passengers.",
            "chapter": null,
            "content": "",
            "footnote": "",
            "is_definition": false,
            "sort_order": 36
        },
        {
            "number": "38",
            "title": "38. Additional Exemptions.",
            "chapter": null,
            "content": "(a) any ship while under construction;\n(b) any ship while undergoing trails;\n(c) any tug;\n(d) any other ship to which these rules apply;\n(i) exempt any ship from the requirement of these rules if it is satisfied that corresponding advantages are provided in the ship so that crew accommodation, considered as a whole, is equivalent or superior in standard to that required by these rules;or\n[(ii) exempt any ship being --\n(a) a sea going ferry or a feeder ship which is not continuously manned with permanent crew; or\n(b) a seas going ship when it temporarily carries repair personnel on board in addition to ship's crew or\n(c) a sea-going ship engaged on short voyages when members of crew are allowed to go ashore for some part to the day.",
            "footnote": "",
            "is_definition": false,
            "sort_order": 37
        },
        {
            "number": "39",
            "title": "39. Penalties.",
            "chapter": null,
            "content": "First Schedule\nFirst Schedule\n[See rules 2(1) (m) and 12 (3)]\nTrunked Mechanical Ventilation System\n1.\n2.\n3.\n4.\n5.\n6.\n7.\n8.\nCategory\nCategory\nSpace\nSpace\nFresh\n air changes per hour\nFresh\n air changes per hour\nVolume\n of fresh air, in cubic metres per minute, for each person likely\n to use the room at any one time\nVolume\n of fresh air, in cubic metres per minute, for each person likely\n to use the room at any one time\n1\n2\n3\n4\nA.\nA.\nRoom other than\n rooms in category (c) in deck houses above the upper or shelter\n deck :-\n(1)outside\n rooms (other than rooms adjoining machinery casing)\n(2) inside rooms\n and rooms adjoining machinery casing.\n10\n15\n[1.42\n cubic meters per minute]\n[1.42\n cubic meters per minute]\nB\nB\nRooms (other than\n rooms in Category C in side-to-side superstructures above the\n upper or shelter deck :-)\n(1)\n outside rooms (other than rooms adjoining machinery casing).\n(2) inside rooms\n and rooms adjoining machinery casing.\n12\n15\n[1.42\n cubic meters per minute]\n[1.42\n cubic meters per minute]\nC\nC\nMess rooms,\n smoking rooms and recreation rooms (in each case above the upper\n or shelter decks :-\n(1)\n not adjoining machinery casing\n(2) adjoining\n machinery casing\n15\n18\n[0.71\n cubic meter per minute]\n[0.71\n cubic meter per minute]\nD\nD\nPassageways\n adjoining machinery casings\n4\nE\nE\nRooms in between\n decks (including shelter\"tween decks) of ships propelled by\n internal combustion machinery\n(1)\n Rooms clear of machinery casing.\n(2)\n Rooms abreast of but not adjoining machinery casing.\n(3)\n Rooms adjoining machinery casing (other than mess rooms, smoking\n rooms and recreation rooms).\n(4) Mess rooms,\n smoking rooms, and recreation rooms (in each case adjoining\n machinery casing).\n12\n12\n15\n18\n[1.42\n cubic meters per minute]\n[1.42\n cubic meters per minute]\n[1.70\n cubic meters per minute]\n[1.71\n cubic meters per minute]\nF\nF\nRooms in between\n decks (including shelter tween decks) of steamships :-\n(1)\n Rooms clear of machinery casing\n(2)\n Rooms abreast of, but not adjoining machinery casing.\n(3)\n Rooms immediately above machinery casing or abreast of and\n adjoining machinery casing (other than mess rooms, smoking rooms\n and recreation rooms)\n(4) Mess room,\n smoking rooms and recreation rooms (in each case adjoining\n machinery casing)\n12\n15\n18\n18\n[1.42\n cubic meters per minute]\n[1.70\n cubic meters per minute]\n[1.70\n cubic meters per minute]\n[0.85\n cubic meters per minute]\n(a)\n whatever the number of persons likely to use the room at one\n time, the total volume of fresh air per minute shall not be\n required to be such as would result in more than 20 fresh air\n changes per hour.\n(b) Whatever the\n number of persons likely to use the room at any one time, the\n total volume of fresh air per minute shall not be required to be\n such as would result in more than 24 fresh air changes per hour.\nCategory\nCategory\nSpace\nSpace\nFresh\n air change per hour\nFresh\n air change per hour\nSupply\n Exhaust\nSupply\n Exhaust\nSupply\n Exhaust\nSupply\n Exhaust\n1\n2\n3\n4\nG\nG\nGalleys\n20(c)(d)\n40(d)\nH\nH\nSanitary\n accommodation, drying rooms and pantries\n10\n-\nJ\nJ\nWards\n in permanent hospitals\n12\nor\n such greater number as would result in the supply of not less\n than 1.42 cubic meters of fresh air per minute for each bed in\n the room.\n-\nK\nK\nDry\n provision store rooms.\nNot\n less than 10(e) and not more than 20.\n-\n(c) 15, if at least two sides of the galley are exposed to the weather.\n(d) The Central Government may exempt any ship from these requirements to the extent that it is satisfied that compliance therewith is unnecessary by reason of the insulation of the equipment in the galley, or by reason of the size of the galley.\n(e)Subject to the provision of rule 29 (4).\nSecond Schedule\nSecond Schedule\n[See rules 7(2) and 8(3)]\nDeck Sheathings\n(a) Foothold.\n(b) Thermal Insulation.\n(i) If the material covers a deck exposed to the weather it shall provide thermal insulation not less than that provided by a wooden deck 5.8 centimetres thick.\n(ii) If the material covers any other deck, it shall provide a warm and comfortable surface.\n(c) Fire Resistance.\n(d) Water Absorption.\n(e) Adhesion.\n(f) Non-corrosion.\n(g) Danger to Persons.\n(h) Resistance to Wear and Weather.\n2.\n3.\nThird Schedule\n[See rule 7(2)]\nInsulating Material for the Underside of Decks\n(a) Thermal Insulation.\n(b) Fire Resistance.\n(c) Adhesion.\n(d) Non-corrosion.\nFourth Schedule\nFourth Schedule\n(See rule 15]\nMarkings\nPart I\nPart I\nPart II\nPart II\nMarking for Spaces other than Sleeping Rooms",
            "footnote": "",
            "is_definition": false,
            "sort_order": 38
        }
    ],
    "metadata": {
        "Act ID": "1782",
        "Act Number": "Published vide Notification Gazette of India, 1960, Extraordinary, Part 2, Section 3(i), page 741.",
        "Enactment Date": "",
        "Act Year": "1960",
        "Short Title": "The Merchant Shipping (Crew Accommodation) Rules, 1960",
        "Type": "CENTRAL",
        "Location": "India (Central)"
    },
    "updated_at": "2026-09-29 21:55:18"
}