{
    "act_title": "The M.P. Factories Rules, 1962",
    "act_slug": "the-m-p-factories-rules-1962",
    "section_label": "Section",
    "section": {
        "number": "72E",
        "title": "72E. Prohibition on performance of other Duties.",
        "chapter": null,
        "content": "[Rules prescribed under Section 41]\n[Rules prescribed under Section 41]\n[73. Protective appliances.\nProtective Equipment.\n[73A. Ovens and Driers.\n(1) Application.\n(2) Definition.\n(3) Separate electrical connection.\n(4) Design, Construction, examination and testing.\n(b) No oven or drier shall be taken into use in a factory for the first time unless a competent person has thoroughly examined all its part and carried out the tests as are required to establish that the necessary safe system and controls provided for safety in operation for the processes for which it is to be used and a certificate of such examination and tests signed by that competent person has been obtained and is kept available for inspection;\n(c) All parts of an oven or drier which has undergone any alteration or repair which has the effect of modifying any of the design characteristics, shall not be used unless a thorough examination and tests as have been mentioned in clause (b) has been carried out by a competent person and a certificate of such examination and tests signed by that competent person has been obtained and is kept available for inspection;\n(d) Competent person for the purpose of this rule shall be the person who is graduate or diploma engineer in electrical or mechanical branch and has atleast 5 years working experience of designing or manufacturing or repairing and maintenance of such equipments.\n(5) Safety Ventilation.\n(b) The safe level of dilution referred to in clause (a) shall be so as to achieve a concentration of the concerned flammable substance in air of not more than 25 per cent of its lower explosive limit :\n(i) shows continuously the concentration of the flammable substance in air present in the oven or drier at any instance;\n(ii) sounds an alarm when the concentration of the flammable substance in air in any part of the oven or drier reaches a level of 50 per cent of its lower explosive; and\n(iii) shuts down the heating system of the oven or drier automatically when the concentration in air if the flammable substance in any part of the oven or drier reaches a level of 60 per cent of its lower explosive limit, is provided to a oven or drier and maintained in efficient working condition.\n(c) No oven or drier shall be operated without its safety ventilation system working in an efficient manner.\n(d) No oven or drier shall be operated with a level of dilution less than what is referred to in clause (b).\n(e) Exhaust dusts of safety ventilation system should be so designed and placed that their dust discharge the mixture of air and flammable substance away from the work-rooms and not near windows or doors or other openings from where the mixture could re-enter the work-rooms.\n(f) The fresh air admitted into the oven or drier by means of the safety ventilation system shall be circulated adequately by means of circulating fan or fans through all parts of the oven or drier so as to ensure that there are no locations where the flammable substance can accumulate in the air become pocketed to any dangerous degree.\n(g) Throttling dampers in any safety ventilation system should be so designed by cutting away a portion of the damper or otherwise, that the system will handle atleast the minimum ventilation rate required for safety when they are set in their maximum throttling position.\n(6) Explosion panels.\n(b) The explosion releasing panels, shall, as far as practicable, be situated at the roof of the oven or drier or at those portions of the walls where persons do not remain in connection with operation of the oven or drier.\n(7) Interlocking arrangements.\n(i) all ventilating fans and circulating fans whose failure would adversely effect the ventilation rate or flow pattern, are in operation before any mechanical conveyor that may be provided for feeding the articles or substances to be processed in the oven or drier is put into operation;\n(ii) failure of any of the ventilating or circulating fans will automatically stop any conveyor as referred to in clause (i) as may be provided, as well as stop the fuel supply by closing the 'shut off valve and shut off' the ignition in the case of gas or oil fired ovens, and in the case of electrically heated ovens switch off the electrical supply to the heaters;\n(iii) the above said mechanical conveyor is set in operation before the above said shut-off valve can be energised; and\n(iv) the failure of the above said conveyor will automatically close the above said shut off valve in the case of ovens and driers heated by gas, oil or steam and deactivate the ignition systems, or cut off the electrical heaters in the case of electrically heated ovens or furnaces.\n(8) Automatic preventilation.\n(9) Temperature Control.\n(10) Multistage processes.\n(11) Combustible substances not to drip on electrical heaters or burners flames.\n(12) Periodical examination testing and maintenance.\n(b) A register shall be maintained in which the details of the various tests carried out from time to time under clause (a) shall be entered and every entry made shall be signed by the person making the tests.\n(13) Training of operations.\n(14) Polymerising machines.\n(b) Infra-red ray heaters of polymerising machines shall be cut-off while running the prints.]\n[73B. Fragile roofs provision of Crawling Boards etc.\n(a) suitable and sufficient ladders, duck ladders or crawling boards which shall be securely supported, are provided and used; and\n(b) permit to work on fragile roof is issued to him each time he is required to work thereon by a responsible person of the factory concerned.]\n[73C. Buildings and structures.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 151
    },
    "prev_section": "72D",
    "next_section": "73E"
}