        "title": "21. Record of white-washing, etc.",
        "chapter": null,
        "content": "Rules prescribed under sub-section (2) of Section 12\nRules prescribed under sub-section (2) of Section 12\n[22. Disposal of Trade Wastes, Effluents and emissions.\n[23. Ventilation and temperature.\nSchedule\nDry-bulb temperature\nDry-bulb temperature\nWet-bulb temperature\nWet-bulb temperature\n30°C to 34°C\n29°C\n35°C to 39°C\n28.5°C\n40°C to 44°C\n28°C\n45°C to 47°C\n27.5°C :\n(b) If the Inspector has reason to believe that a substantial amount of heat is added inside environment of a workroom by radiation from walls, roof or other solid surroundings, he may serve on the manager of the factory an order requiring him to place the globe thermometers referred to in the first proviso in sub-rule (1) at place specified by him and keep a record of the temperature in a suitable register.\n(i) covered by Section 15; or\n(ii) in which temperature and humidity are controlled by refrigeration, and air conditioning.\n(b) Where in any factory owing to special circumstances such situation with respect to adjacent buildings and height of the building with respect to floor space, the requirements of ventilation openings under clause (a) of this sub-rule he may serve on the manager of the factory an order requiring him to provide additional ventilation either by means of roof ventilators or by mechanical means.\n(c) The amount of fresh air supplied by mechanical means of ventilation in an hour shall be equivalent to at least six times the cubic capacity of the workroom and shall be distributed evenly throughout the workroom without dead air pockets or undue draughts cansed by high inlet velocities.\n(d) In regions where in summer (15th March, 15th July) dry-bulb temperature of outside air in the shade during most part of the day exceed 35 degrees Celsius and simultaneous wet-bulb temperatures are 25 degrees celsius or below and in the opinion of the Inspector the manufacturing process carried on the workroom of a factory permits thermal environments with relative humidity of 50% or more, the Inspector may serve on the manager of the factory an order to have sufficient supply of outside air for ventilation cooled by passing it through water sprays either by means of unit type of evaporative air coolers (desert coolers) or, where supply of outside air is provided by mechanical means through ducts in a plenum system, by means of central air washing plants.]\nRules 24 to 34 prescribed under sub-section (1) of Section 15\nRules 24 to 34 prescribed under sub-section (1) of Section 15\n[24. When artificial humidification not allowed.\n(a) by the use of steam during any period when the dry-bulb temperature of that room exceeds 29.5 degrees celsius; and\n(b) at any time when the wet-bulb reading of the hygrometer is higher than that specified in the following Schedule in relation to the dry-bulb reading of the hygrometer at that time; or as regards a dry-bulb reading intermediate between any two dry-bulb readings indicated consecutively in the schedule when the dry-bulb reading does not exceed the wet-bulb reading to the extent indicated in relation to the lower of these two dry-bulb readings :-\nSchedule\nReading in degrees celsius\nReading in degrees celsius\nDry-bulb\nWet-bulb\nDry bulb\nWet-bulb\nDry-bulb\nWet-bulb\n(1)\n(2)\n(1)\n(2)\n(1)\n(2)\n15.5\n14.5\n25.0\n24.0\n34.5\n30.0\n16.0\n15.0\n25.5\n24.5\n35.0\n30.5\n16.5\n15.5\n26.0\n25.0\n35.5\n31.0\n17.0\n16.0\n26.5\n25.5\n36.0\n31.0\n17.5\n16.0\n27.0\n26.0\n36.5\n31.5\n18.0\n16.5\n27.5\n26.0\n37.0\n31.5\n18.5\n17.0\n28.0\n26.5\n37.5\n31.5\n19.0\n18.0\n28.5\n27.0\n38.0\n32.0\n19.5\n18.5\n29.0\n27.0\n38.5\n32.0\n20.0\n19.0\n29.5\n28.0\n39.0\n32.0\n20.5\n19.5\n30.0\n28.0\n39.5\n32.5\n21.0\n20.0\n30.5\n28.5\n40.0\n32.5\n21.5\n20.5\n31.0\n28.5\n40.5\n33.0\n22.0\n21.0\n31.5\n29.0\n41.0\n33.0\n22.5\n21.0\n32.0\n29.0\n41.5\n33.0\n23.0\n21.5\n32.5\n29.0\n42.0\n33.0\n23.5\n22.0\n33.0\n29.5\n42.5\n33.0\n24.0\n23.0\n33.5\n29.5\n43.0\n33.5\n24.5\n23.5\n34.0\n30.0\n43.5\n33.5",
        "footnote": "",
        "is_definition": false,
        "sort_order": 15
    },
    "prev_section": "20",
    "next_section": "25"
}