    "act_title": "The M.P. Bhumi Vikas Rules, 1984",
    "act_slug": "the-m-p-bhumi-vikas-rules-1984",
    "section_label": "Section",
    "section": {
        "number": "89",
        "title": "89. Requirements of Sanitary fittings.",
        "chapter": null,
        "content": "Table-14\nTable-14\nSanitation Requirements for shops and Commercial Offices\nSanitation Requirements for shops and Commercial Offices\nS.No.\nS.No.\nFitments\nFitments\nFor Personnel\nFor Personnel\n1.\nWater closet\nOne for every 25 persons or part thereof exceeding 15\n\t\t\t\t\t(including employees and customers).\nFor female personnel 1 for every 15 persons or part thereof\n\t\t\t\t\texceeding 10.\n2.\nDrinking Water Fountain\nOne for every 100 persons with a minimum of one on each\n\t\t\t\t\tfloor.\n3.\nWash Basin\nOne for every 25 persons or part thereof.\n4.\nUrinals\nSame as at serial No. 3 of Table 19.\n5.\nCleaner's Sink\nOne per floor minimum, preferably in or adjacent to sanitary\n\t\t\t\t\trooms.\nNote. - Number of customers for the purpose of the above calculation shall be the average number of persons in the premises for a time interval of one hour during the peak period. For male-female calculation of ratio 1:1 may be assumed.\nNote.\nTable-15\nTable-15\nSanitation Requirements for hotels\nSanitation Requirements for hotels\nS. No.\nFitments\nFor residential public and staff\nFor public rooms\nFor non-residential staff\nFor males\nFor females\nFor male\nFor female\n1\n2\n3\n4\n5\n6\n7\n1.\nWater Closet\n1 per 8 persons omitting occupants of the room with attached\n\t\t\t\twater closet, minimum of 2 in both sexes lodged\n1 per 100 persons upto 400 persons for over 400 add at the\n\t\t\t\trate of 1 per 250 persons or part thereof\n2 for 100 persons up to 200 persons over 200 add at the rate\n\t\t\t\tof 1 per 100 or part thereof\n1 for 1-15 2 for 16-35 3 for 36-65 4 for 66-100\n1 for 1-12 2 for 13-25 3 for 26-40 4 for 41-57\n2.\nAblution taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closet\n\t\t\t\tand urinal.\n3.\nUrinals\n1 for 50 persons or part thereof\nPersons Nil up to 6 1 for 7-20 2 for 21-40 3 for\n\t\t\t\t41-70 4 for 71-100\n4.\nWash basins\n1 per 10 persons omitting the wash basins installed in the\n\t\t\t\troom suites\n1 per water closet and urinal provided\n1 for water closet provided\nPersons 1 for 1-15 2 for 16-35 3 for 36-65 4 for\n\t\t\t\t66-100\nPersons 1 for 1-12 2 for 13-25 3 for 26-40 4 for\n\t\t\t\t41-57 5 for 58-77 6 for 78-100\n5.\nBaths\n1 per 10 persons omitting occupants of the room with bath in\n\t\t\t\tsuite\n6.\nSlop sinks\n1 for 30 bed rooms (one per floor minimum)\n7.\nKitchen sinks\n1 in each kitchen\n1 in each kitchen\n1 in each kitchen\n1 in each kitchen\n1 in each kitchen\nNote. - It may be assumed that the two-thirds of the number are males and one third females.\nNote.\nTable-16\nTable-16\nSanitation requirements for Educational Occupancy\nSanitation requirements for Educational Occupancy\nNo.\nFitments\nNursery Schools\nBoarding Institution\nOther Educational Institutions\nFor Boys\nFor Girls\nFor Boys\nFor Girls\n1\n2\n3\n4\n5\n6\n7\n1.\nWater Closet\nOne per 30 pupils or part thereof\nOne per 8 pupils or part thereof\nOne per 6 pupils or part thereof\nOne per 80 pupils or part thereof\nOne per 50 pupils or part thereof\n2.\nAblution Tap\nOne in each water closet\nOne in each water closet\nOne in each water closet\nOne in each water closet\nOne in each water closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity.\n3.\nUrinals\nOne per 25 pupils or part thereof\nOne per 20 pupils or part thereof\n4.\nWash Basin\nOne per 30 pupils or part thereof\nOne per 8 pupils or part thereof\nOne per 60 pupils or part thereof\nOne per 80 pupils or part thereof\nOne per 80 pupils or part thereof\n5.\nBaths\nOne bath sink per 40 pupils\nOne or every 8 pupils or part thereof\nOne for every 6 pupils or part thereof\nNil\nNil\n6.\nDrinking water fountains\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\n7.\nCleaners sink\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nNote. - For teaching staff, the schedule of fitments shall be the same as in the case of office buildings (table 19).\nNote.\nTable 17\nTable 17\nSanitation Requirements for Institutional (Medical) occupancy Hospitals\nSanitation Requirements for Institutional (Medical) occupancy Hospitals\nS. No.\nFitments\nHospitals with indoor patient wards\nHospitals with outdoor patient wards\nAdministrative building\nFor males and for females\nFor males\nFor females\nFor male personnel\nFor female personnel\n1\n2\n3\n4\n5\n6\n7\n1.\nWater Closet\nOne for every 8 beds or part thereof\nOne for every 100 persons or part thereof\nTwo for every 100 persons or part thereof\nOne for every 25 persons or part thereof\nOne for every 15 person of part thereof\n2.\nAblution Taps\nOne in each water Closet\nOne in each water Closet\nOne in each water Closet\nOne in each water Closet\nOne in each water Closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closet\n\t\t\t\tand urinals.\n3.\nWash Basins\n2 up to 30 bed add one for every additional 30 beds or part\n\t\t\t\tthereof.\nOne for every 100 persons or part thereof\nOne for every 100 persons or part thereof\nOne for every 25 persons or part thereof\nOne for every 4 persons or part thereof\n4.\nBaths with shower\nOne Bath with shower for every 8 beds or part thereof\n–\n–\nOne on each floor\nOne on each floor\n5.\nBed pan washing sinks\nOne for each ward\n–\n–\n–\n–\n6.\nCleaners sink\nOne for each ward\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\n7.\nKitchen sinks and dish washes (where kitchen is provided)\nOne for each ward\n–\n–\n–\n–\n8.\nUrinals\n–\nOne for every 50 persons or part thereof\n–\n–\nOne up to 20 persons 2-for 21-45 persons 3-for 46-70\n\t\t\t\tperson 4-for 71-100 persons for 101 to 200 persons add at\n\t\t\t\tthe rate of 3 percent For over 200 persons add at the rate of\n\t\t\t\t2.5 percent\nTable 18\nTable 18\nSanitation requirements for Institutional (Medical) Occupancy (Staff Quarters & Hostels)\nSanitation requirements for Institutional (Medical) Occupancy (Staff Quarters & Hostels)\nS. No.\nFitments\nDoctor's Dormitories\nNurses Hostel\nFor male staff\nFor female staff\n1\n2\n3\n4\n5\n1.\nWater closet\nOne for 4 persons\nOne for 4 persons\nOne for 4 persons or part thereof\n2.\nAblution taps\nOne in each water closet\nOne in each water closet\nOne in each water closet\n3.\nWash Basins\nOne for every 8 persons or part thereof\nOne for every 8 persons or part thereof\nOne for every 8 persons or part thereof\n4.\nBaths (with shower)\nOne for 4 persons or part thereof\nOne for 4 persons or part thereof\nOne for 6 persons or part thereof\n5.\nCleaner's sinks\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nTable 19\nTable 19\nSanitation Requirements for Governmental and public business occupancies and offices\nSanitation Requirements for Governmental and public business occupancies and offices\nS. No.\nFitments\nFor males personnel\nFor female personnel\n1\n2\n3\n4\n1.\nWater closet\nOne for every 25 persons or part thereof\nOne for every 15 persons or part thereof\n2.\nAblution taps\nOne in each water closet.\nOne in each water closet\nOne water tap with draining arrangement shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand urinals.\n3.\nUrinals\nNil up to 6 persons One for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons For 101\n\t\t\t\tto 200 persons add at the rate of 3 percent. For over 200\n\t\t\t\tpersons add at the rate of 2.5 percent.\n4.\nWash basins\nOne for every 250 persons or part thereof.\n5.\nDrinking water fountains\nOne for every 100 persons with a minimum of one for each\n\t\t\t\tfloor.\n6.\nBaths\nPreferably one on each floor\n7.\nCleaners Sinks\nOne per floor minimum preferably in or adjacent to sanitary\n\t\t\t\trooms\nTable - 20\nTable - 20\nSanitation requirements for residences\nSanitation requirements for residences\nS. No.\nFitments\nDwelling with individual conveniences\nDwelling without individual Conveniences\n(1)\n(2)\n(3)\n(4)\n1.\nBath Rooms\n1 provided with water tap\n1 for every three tenements\n2.\nWater closet\n1\n1 for every three tenements\n3.\nSink (or NAHANI) in the floor\n1\n4.\nWater Tap\n1\n1 with draining arrangements in each tenement in common bath\n\t\t\t\trooms and common water closets\nNote. - Where only one water closet is provided in a dwelling, the bath and water closet shall be separately accommodated.\nNote.\nTable 21\nTable 21\nSanitation Requirements for Assembly Occupancy Buildings (Cinema, Theatres and Auditoria)\nSanitation Requirements for Assembly Occupancy Buildings (Cinema, Theatres and Auditoria)\nS. No.\nFitments\nFor public\nFor staff\nMale\nFemale\nMale\nFemale\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n1.\nWater closets\n1 per 100 persons up to 400 persons.\n3 per 100 persons up to 200 persons.\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\nFor over 400 persons, add at the rate of 1 per 250 persons or\n\t\t\t\tpart thereof.\nFor over 200 persons add at the rate of 2 per 100 persons or\n\t\t\t\tpart thereof.\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand urinals.\n3.\nUrinals\n1 for 50 persons or part thereof\nNil up to 6 persons. 1 for 7-20 persons. 2 for 21-45\n\t\t\t\tpersons.\n4.\nWash basins\n1 for every 200 persons or part thereof.\n1 for every 200 persons part thereof.\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\n5.\nDrinking water Fountains\n1 for 100 persons or part thereof\nNote. - It may be assumed that two-thirds of the number are males and one-third females.\nNote.\nTable-22\nTable-22\nSanitation Requirements for Assembly Occupancy Buildings (Art Galleries, Libraries and Museums)\nSanitation Requirements for Assembly Occupancy Buildings (Art Galleries, Libraries and Museums)\nS. No.\nFitments\nFor public\nFor staff\nMale\nFemale\nMale\nFemale\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n1.\nWater closets\n1 per 200 persons up to 400 persons. For over 400 persons, add\n\t\t\t\tat the rate of 1 per 250 person or part thereof.\n1 per 100 persons up to 200 persons. For over 200 persons, add\n\t\t\t\tat the rate of 1 per 150 person or part thereof.\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet.\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 per sons or part thereof in the vicinity of water\n\t\t\t\tclosets and urinals.\n3.\nUrinals\n1 for 50 persons\nNil up to 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\tperson\n4.\nWash basins\n1 for every 200 persons or part thereof. For over 400 persons\n\t\t\t\tadd at the rate of 1 per 250 persons or part thereof.\n1 for every 200 persons or part thereof. For over 200 persons\n\t\t\t\tadd at the rate of 1 per 150 persons or part thereof.\n1 for 1-15 persons 2 for 16-25 persons\n1 for 1-12 persons 2 for 13-25 persons\n5.\nCleaners Sinks\n1 per floor minimum.\nNote. - It may be assumed that two-thirds of the number are males and one-third females.\nNote.\nTable-23\nTable-23\nSanitation Requirements for Restaurants\nSanitation Requirements for Restaurants\nS. No.\nFitments\nFor public\nFor staff\nMale\nFemale\nMale\nFemale\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n1.\nWater closets\n1 for 50 seats upto 200 seats. For over 200 seats add at\n\t\t\t\tthe rate of one per 100 seats or part thereof.\n1 for 50 seats upto 200 seats. For over 200 seats, add at\n\t\t\t\tthe rate of one per 100 seats or part thereof.\n1 for 1-15 persons. 2 for 16-35 persons 3 for 36-65\n\t\t\t\tpersons 4 for 66-100 persons\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t78-100 persons\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet.\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand urinals.\n3.\nUrinals\nOne per 50 seats.\nNil upto 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons\n4.\nWash basins\n1 for every water closet provided.\n5.\nKitchen sinks and dish washer\n1 in each kitchen.\n6.\nStop or service sink.\n1 in the restaurant.\nNote. - It may be assumed that two-thirds of the number are males and one-third females.\nNote.\nTable - 24\nTable - 24\nSanitation Requirements for Factories\nSanitation Requirements for Factories\nS. No.\nFitments\nFor Male personnel\nFor Female personnel\n(1)\n(2)\n(3)\n(4)\n1.\nWater closets\n1 for 1-15 persons 2 for 16-35 persons 3 for 36-65\n\t\t\t\tpersons 4 for 66-100 persons For 101 to 200 persons, add at\n\t\t\t\tthe rate of 3 percent. For over 200 persons and at the rate of\n\t\t\t\t2.5 percent\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t78-100 persons For 101 to 200 persons, add at the rate of 5\n\t\t\t\tpercent. For over 200 persons add at the rate of 4 percent.\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet.\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand in urinals.\n3.\nUrinals\nNil up to 6 persons. 1 for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons For 101\n\t\t\t\tto 200 persons add at the rate of 3 percent. For over 200\n\t\t\t\tpersons add at the rate of 2.5 percent.\n4.\nWashing taps with draining arrangements\n1 for every 25 persons or part thereof.\n1 for every 25 persons or part thereof.\n5.\nDrinking water Fountains\n1 for every 100 persons with a minimum of one on each floor.\n6.\nBaths (preferably showers)\nAs required for particular trades or occupations.\nNote. - For many trades of a dirty or dangerous character, more extensive provisions are required.\nNote.\nTable - 25\nTable - 25\nSanitary Requirements for Large Stations and Airports\nSanitary Requirements for Large Stations and Airports\nSl.No.\nPlace\nWC for Males\nWC for female\nUrinals for Males only\n(1)\n(2)\n(3)\n(4)\n(5)\n1.\nJunction station intermediate stations and bus stations.\n3 for first 1000 persons and 1 for every subsequent 1000\n\t\t\t\tpersons or part there of.\n4 for first 1000 persons and 1 for every additional 1000\n\t\t\t\tpersons or part thereof.\n4 for every 1000 persons and 1 for a very additional 1000\n\t\t\t\tpersons or part thereof.\n2.\nTerminal stations and bus terminals\n4 for first 1000 persons and 1 for every subsequent 1000\n\t\t\t\tpersons or part thereof.\n5 for first 1000 persons and 1 for every subsequent 2000\n\t\t\t\tpersons or part thereof.\n6 for first 1000 persons and 1 for every additional 1000\n\t\t\t\tpersons or part thereof.\n3.\nDomestic Airports, Min.\nfor 200 persons\nfor 400 persons\nfor 600 persons\nfor 800 persons\nfor 1000 persons\n2*\n5\n9\n12\n16\n18\n4*\n8\n15\n20\n26\n29\n2*\n6\n12\n16\n20\n22\n4.\nInternational airports\nfor 200 persons\nfor 600 persons\nfor 1000 persons\n6\n12\n18\n10\n20\n29\n8\n16\n22\nNote. - Provision for wash basins, baths including shower stalls, shall be in accordance with Part IX Section 2 Drainage and Sanitation of the Code.\nNote.\n(x) Special Requirements of Individual Occupancies\n(x) Special Requirements of Individual Occupancies",
        "footnote": "",
        "is_definition": false,
        "sort_order": 83
    },
    "prev_section": "88",
    "next_section": "90"
}