    "act_title": "The Environment (Protection) Rules, 1986",
    "act_slug": "the-environment-protection-rules-1986",
    "section_label": "Section",
    "section": {
        "number": "72",
        "title": "72. Oil Drilling and Gas Extraction Industry A.\nStandards for Liquid Effluent 1.0\nOn-Shore facilities (For Marine Disposal) pH 5.5-9.0 Oil & Grease 10 mg/l Suspended solids 100 mg/l BOD\n(3 days at 27°C) 30 mg/l",
        "chapter": null,
        "content": "5.5-9.0\n10 mg/l\n100 mg/l\n30 mg/l\nNotes.\nParameter Toxicity limit, mg/l Chromium as Cr 0.1 Copper, as Cu 0.05 Cyanide, as CN 0.005 Fluoride, as F 1.5 Lead, as Pb 0.05 Mercury, as Hg 0.01 Nickel, as Ni 0.1 Zinc, as Zn 0.1\nParameter\nToxicity limit, mg/l\nChromium as Cr\n0.1\nCopper, as Cu\n0.05\nCyanide, as CN\n0.005\nFluoride, as F\n1.5\nLead, as Pb\n0.05\nMercury, as Hg\n0.01\nNickel, as Ni\n0.1\nZinc, as Zn\n0.1\n(ii) Oil and gas drilling and processing facilities, situated on land and away from saline water sink, may opt either for disposal of treated water by on-shore disposal of by re-injection in abandoned well, which is allowed only below a depth of 1000 metres from the ground level. In case of re-injection in abandoned well the effluent have to comply only with respect to suspended solids and oil and grease at 100 mg/l and 10 mg/l, respectively. For on- shore disposal, the permissible limits are giveN below:\nSl . No. Parameter On-shore discharge standards (Not to exceed) 1 2 3 1. pH 5.5-9.0 2. Temperature 40°C 3. Suspended Solids 100 mg/l 4. Zinc 2 mg/l 5. BOD 30 mg/l 6. COD 100mg/1 7. Chlorides 600 mg/l 8. Sulphates 1000 mg/l 9. TDS 2100 mg/l 10. %Sodium 60 mg/l 11. Oil and Grease 10 mg/l 12. Phenolics 1.2 mg/l 13. Cyanides 0.2 mg/l 14. Fluorides 1.5 mg/l 15. Sulphides 2.0 mg/l 16. Chromium (Cr+6) 0.1 mg/l 17. Chromium (Total) 1.0 mg/l 18. Copper 0.2 mg/l 19. Lead 0.1 mg/l 20. Mercury 0.01 mg/l 21. Nickel 3.0 mg/l\nSl . No.\nSl\n. No.\nParameter\nOn-shore discharge standards (Not to exceed)\nOn-shore discharge standards (Not to exceed)\n1\n1\n2\n2\n3\n3\n1.\npH\n5.5-9.0\n2.\nTemperature\n40°C\n3.\nSuspended Solids\n100 mg/l\n4.\nZinc\n2 mg/l\n5.\nBOD\n30 mg/l\n6.\nCOD\n100mg/1\n7.\nChlorides\n600 mg/l\n8.\nSulphates\n1000 mg/l\n9.\nTDS\n2100 mg/l\n10.\n%Sodium\n60 mg/l\n11.\nOil and Grease\n10 mg/l\n12.\nPhenolics\n1.2 mg/l\n13.\nCyanides\n0.2 mg/l\n14.\nFluorides\n1.5 mg/l\n15.\nSulphides\n2.0 mg/l\n16.\nChromium (Cr+6)\n0.1 mg/l\n17.\nChromium (Total)\n1.0 mg/l\n18.\nCopper\n0.2 mg/l\n19.\nLead\n0.1 mg/l\n20.\nMercury\n0.01 mg/l\n21.\nNickel\n3.0 mg/l\n(a) Drill Cuttings (DC) originating from on-shore or locations close to shore line and separated from Water Base Mud (WBM) should be properly washed and unusable drilling fluids (DF) such as WBM, Oil Base Mud (OBM), Synthetic Base Mud (SBM) should be disposed off in a well designed pit lined with impervious liner located off-site or on-site. The disposal pit should be provided additionally with leachate collection system.\n(b) Use of diesel base mud is prohibited. Only WBM should be used for on-shore oil drilling operations.\n(c) In case of any problem due to geological formation for drilling, low toxicity OBM having aromatic content<1% should be used. If the operators intend to use such OBM to mitigate specific whole problem/SBM it should be intimated to Ministry of Environment and Forests/State Pollution Control Board.\n(d) The chemical additives used for the preparation of DF should have low toxicity, i.e., 96 hr LC50>30,000 mg/1 as per mysid toxicity or toxicity test conducted on locally available sensitive sea species. The chemicals used (mainly organic constituents) should be biodegradable.\n(e) DC separated from OBM after washing should have oil content at < 10 mg/kg for disposal into disposal pit.\n(f) The waste pit after it is filled up shall be covered with impervious liner, over which, a thick layer of native soil with proper top slope is provided.\n(g) Low toxicity OBM should be made available at installation during drilling operation.\n(h) Drilling wastewater including DC wash water should be collected in the disposal pit evaporated or treated and should comply with the notified standards for on-shore disposal.\n(i) Barite used in preparation of DF shall not contain Hg>1 mg/kg and Cd>3 mg/kg.\n(j) Total material acquired for preparation of drill site must be restored after completion of drilling operation leaving no waste material at site. SPCB should be informed about the restoration work.\n(k) In case, environmentally acceptable methods for disposal of drill waste such as (a) injection to a formation through casing annuals, if conditions allow (b) land farming at suitable location (c) bio-remediation (d) incineration or (e) solidification can be considered, in such cases oil industry is required to submit proposal to Ministry of Environment and Forests/State Pollution Control Board (MoEF/SPCB) for approval.\n(a) Use of diesel base mud is prohibited. Only WBM is permitted for off-shore drilling. If the operator intend to use low toxicity OBM or SBM to mitigate specific hole problems in the formation, it should be intimated to MoEF/SPCB. The low toxicity OBM should have aromatic content<1%.\n(b) The toxicity of chemical additives used in the DF (WBM or OBM or SBM) should be biodegradable (mainly organic constituents) and should have toxicity of 96 hr LC\u001450\u0014 Value > 30,000 mg/1 as per mysid toxicity or toxicity test conducted on locally available sensitive sea species.\n(c) Hexavalent chromium compound should not be used in DF. Alternative chemical in place of chrome lignosulfonate should be used in DF. In case, chrome compound is used, the DF, DC should not be disposed off-shore.\n(d) Bulk discharge of DF in off-shore is prohibited except in emergency situations.\n(e) WBM/OBM/SBM should be recycled to a maximum extent. Unusable portion of OBM should not be discharged into sea and shall be brought to on-shore for treatment and disposal in an impervious waste disposal pit.\n(f) Thoroughly washed DC separated from WBM/SBM and unusable portion of WBM/SBM having toxicity of 96 hr LC\u001450\u0014 > 30,000 mg/1 shall be discharged off-shore into sea intermittently, at an average rate of 50 bbl/hr/well from a platform so as to have proper dilution and dispersion without any adverse impact on marine environment.\n(g) Drill cutting of any composition should not be discharged in sensitive areas notified by the Ministry of Environment and Forests.\n(h) In case of specific hole problem, use of OBM will be restricted with zero discharge of DC. Zero discharge would include re-injection of the DC into a suitable formation or to bring to shore for proper disposal. In such a case, use of OBM for re-injection should be recorded and made available to the regulatory agency. Such low toxic OBM having aromatic content <1% should be made available at the installation.\n(i) In case, DC is associated with high oil content from hydrocarbon bearing formation, then disposal of DC should not have oil content > 10 gm/kg.\n(j) The DC wash water should be treated to confirm limits notified under EPA, before disposal into sea. The treated effluent should be monitored regularly.\n(k) Discharge of DC from the installation located within 5 km away from shore should ensure that there is no adverse impact on marine Eco-system and on the shore. If, adverse impact is observed, then the industries have to bring the DC on-shore for disposal in an impervious waste disposal pit.\n(l) If any, environmental friendly technology emerges for substitution of DF and disposal technology, it may he brought to the notice of MoEF and regulatory agencies. If the operator desires to adopt such environment friendly technology a prior approval from Ministry of Environment and Forests is required.\n(m) Barite used in preparation of DF shall not contain Hg> 1 Mg/kg and Cd> 3 mg/kg.\n(n) Oil drilling operators are required to record daily discharge of DC and DF to off-shore and also to monitor daily the effluent quality, and submit the compliance report once in every six month to Ministry of Environment and Forests.\n[73. Pharmaceutical (Manufacturing and Formulation) Industry] Effluent Standards (i)\nCompulsory Parameters Limiting concentration in mg/1, expect for pH pH 6.0-8.5 Oil & grease 10 BOD (3 days 27°C) 100* Total suspended solids 100 Bioassay Test 90% survival of fish after first 96\nhours in 100% effluent** (ii) Additional Parameters Mercury 0.01 Arsenic 0.20 Chromium (Cr 6+ ) 0.10 Lead 0.10 Cyanide 0.10 Phenolics (C 6 H 5 SOH) 1.0 Sulphides (as S) 2.0 Phosphate (as P) 5.0\npH\nOil & grease\nBOD (3 days 27°C)\nTotal suspended solids\nBioassay Test\nMercury\nArsenic\nChromium (Cr 6+ )\nLead\nCyanide\nPhenolics (C 6 H 5 SOH)\nSulphides (as S)\nPhosphate (as P)\nNote.\n*The BOD and COD limits shall be 30 mg/1 and 250 mg/1 respectively, if treated effluent is discharged directly into a fresh water body, i.e., steam, canal, river or lake.\n**The Bioassay Test shall he conducted as per IS: 6582-1971.\n(i) Parameters listed as 'Additional Parameters' shall he prescribed depending upon the process and product.\n(ii) Limits for total dissolved solids in effluent shall be prescribed by the concerned pollution control board/pollution control committee depending upon the recipient water body.\n[ A. Emission from Incinerator ]\nA. Emission from Incinerator\nLimiting concentration in mg/Nm 3 , Unless stated\nSampling duration in (minutes) unless stated\nParticulate Matter\n50\n30 or more (for sampling about 300 litre emission)\nHCI\n50\n30\nSO 2\n200\n30\nCO\n100\n30\nTotal Organic Carbon\n20\n30\nTotal Dioxins and Furans*\nExisting Incinerator\n0.2 ng TEQ/Nm 3\n8 hours\nNew Incinerator\n0.1 ng TEQ/Nm 3\n8 hours\nSb+As+Pb+Cr+Co+Cu+Mn+Ni+V+Cd+Th+Hg and their compounds\n1.5\n2 hours\n*The existing plant shall comply with norms for dioxins and\n\t\t\t\tfurans as 0.1 ng/TEQ/ Nm 3 within 5 years from the date\n\t\t\t\tof notification.\nNotes. - (i) All monitored values shall be corrected to 11%\n\t\t\t\toxygen on dry basis.\n(ii) The CO 2 concentration In tall gas shall not be\n\t\t\t\tless than 7%.\n(iii) In case, halogenated organic waste is less than 1% by\n\t\t\t\tweight in input waste, all the facilities in twin chamber\n\t\t\t\tincinerator shall be designed so as to achieve a minimum\n\t\t\t\ttemperature of 850 ± 25°C in primary chamber and 950°C\n\t\t\t\tin secondary combustion chamber and with a gas residence time in\n\t\t\t\tsecondary combustion chamber not less than 2 (two) seconds.\nor\nall the facilities in single chamber incinerator for gaseous\n\t\t\t\thazardous waste shall be designed so as to achieve a minimum\n\t\t\t\ttemperature of 950°C in the combustion chamber with a gas\n\t\t\t\tresidence time not less than 2 (two) seconds.\n(iv) In case halogenated organic waste is more than 1% by\n\t\t\t\tweight in input waste, waste shall be incinerated only in twin\n\t\t\t\tchamber incinerators and all the facilities shall be designed to\n\t\t\t\tachieve a minimum temperature of 850 ± 25°C in primary\n\t\t\t\tchamber and 1100°C in secondary combustion chamber with a gas\n\t\t\t\tresidence time in secondary combustion chamber hot less than 2\n\t\t\t\t(two seconds).\n(v) Scrubber meant for scrubbing emissions shall not be used\n\t\t\t\tas quencher.\n(vi) Incineration plants shall be operated (combustion\n\t\t\t\tchambers) with such temperature, retention time and turbulence,\n\t\t\t\tas to achieve Total Organic Carbon (TOC) content in the\n\t\t\t\tincineration ash and residue less than 3%, and their loss on\n\t\t\t\tignition is less than 5% of the dry weight. In case of\n\t\t\t\tnon-conformity, ash and/or residue shall be re-incinerated.\n(vii) The incinerator shall have a chimney of at least thirty\n\t\t\t\tmetre height.\nB. Effluent from Incinerator\n(i) Effluent from scrubber (s) and floor washing shall flow\n\t\t\t\tthrough closed conduit/pipe network.\n(ii) Storm water shall not be allowed to mix with scrubber\n\t\t\t\twater and/or floor washings.\n(iii) Storm water shall be channelized through separate drains\n\t\t\t\tpassing through a HDPE lined pit having holding capacity of 10\n\t\t\t\tminutes (hourly average) of rainfall.\n(iv) The built up in Total Dissolved Solids (TDS) in\n\t\t\t\twastewater of floor washings shall not exceed 1000 mg/I over and\n\t\t\t\tabove the TDS of raw water used.\n(v) Effluent shall not be stored in holding tank(s) in such\n\t\t\t\tmanner which may cause pollution to groundwater.\"\n(vi) Effluent (scrubber water and floor washings) shall be\n\t\t\t\tdischarged into receiving water conforming to the norms\n\t\t\t\tprescribed under Schedule VI: General Standards for Discharge of\n\t\t\t\tEnvironment Pollutions (Part A: Effluents) notified under the\n\t\t\t\tEnvironment (Protection) Rules, 1986.\n[74. Brick Kilns]\nEmission Standards\n(i) Bull's Trench Kiln (BTK)\nCategory*\nLimiting concentration in mg/Nm 3\nParticular matter\nsmall\n1000\nmedium\n750\nlarge\n750\nMinimum (metre)\nStack height\nsmall\n22 or induced draft fan operating with minimum draft of 50 mm\n\t\t\t\tWG with 12 metre stack height.\nmedium\n27 or induced draft fan operating with minimum draft of 50 mm\n\t\t\t\tWG with 15 metre stack height.\nlarge\n30 or induced draft fan operating with minimum draft of 50 mm\n\t\t\t\tWG with 17 metre stack height.\n*Category\nTrench width (m)\nProduction (bricks/day)\nsmall BTK\n< 4.50\nLess than 15,000\nmedium BTK\n4.50-6.75\n15,000-30,000\nlarge BTK\nabove 6.75\nabove 30,000\n(ii) Down-Draft Kiln (DDK)\nCategory++\nLimiting concentration in mg/ Nm 3\nParticular matter\nsmall/large/medium\n1200\nMinimum (metre)\nStack height\nsmall\n12\nmedium\n15\nlarge\n18\nCategory++\nProduction (bricks/day)\nSmall DDK\nless than 15,000\nmedium DDK\n15,000-30,000\nlarge DDK\nabove 30,000\n(iii) Vertical Shaft Kiln (VSK)\nCategory**\nLimiting concentration in mg/ Nm 3\nParticular matter\nsmall/large/medium\n250\nMinimum (metre)\nStack height\nsmall\n11 (at least 5.5 m from loading platform)\nmedium\n14 (at least 7.5 m from loading platform)\nlarge\n16 (at least 8.5 m from loading platform)\n**Category\nNo. of shaft\nProduction (bricks/day)\nsmall VSK\n1-3\nLess than 15,000\nmedium BTK\n4-6\n15,000-30,000\nlarge BTK\n7 or more\nabove 30,000\nNotes.\nSl.No.\nSl.No.\nIndustry\nIndustry\nParameter\nParameter\nStandard\nStandard\n(1)\n(2)\n(3)\n(4)\n[75]\nSoda Ash Industry\nEffluent\n\t\t\t\tstandards A. Solvay Proces\nEffluent\n\t\t\t\tstandards A. Solvay Proces\nLimiting\n\t\t\t\tConcentrationing mg/1 except for pH, Temperature and Bio-assay\nCreek\nCreek\nMarine Coastal\n\t\t\t\tZone\nMarine Coastal\n\t\t\t\tZone\nEstuary Area\nEstuary Area\nInland Surface\n\t\t\t\tWater\nInland Surface\n\t\t\t\tWater\nSuspended Solids\n500*\n1000*\n200\n100\nAmmonical Nitrogen\n\t\t\t\tas N\n50\n50\n50\n50\nOil and Grease\n5\n5\n5\n5\nBio-assay***\nMinimum 90%\n\t\t\t\tsurvival of fish after 96 hours in 100% effluent\npH\n6.5-9.0\nTempertaure\nNot ot exceed 5°C\n\t\t\t\tabove the ambient temperature of the reveiving water body\n*The effluent\n\t\t\t\tdischarge point in creek shall be beyond low tide line.\n**The diffuser\n\t\t\t\tsystem shall be located in conformity with the Coastal Regulation\n\t\t\t\tZone Notification , 2011 at a minimum depth of 5 metres below low\n\t\t\t\ttide level and with exit velocity for effluent more than 3\n\t\t\t\tmetres/sec\n***The Bio-assay\n\t\t\t\ttest shall be conducted as per IS :6582-1971\nB.\n\t\t\t\tDual Process\nB.\n\t\t\t\tDual Process\nInland\n\t\t\t\tSurface Water\nph\n6.5-9.0\nAmmonical\n\t\t\t\tNitrogen, as N\n50\nNitrate Nitrogen,\n\t\t\t\tas N\n10\nCyanide, as CN\n2\nHexavalent\n\t\t\t\tChromium\n0.1\nTotal Chromium\n2\nSuspended Solids\n100\nOil and Grease\n10\nC.\n\t\t\t\tStormwater\nC.\n\t\t\t\tStormwater\nNote :-\nNote :-\n(i) Stormwater\n\t\t\t\tshall not be allowed to mix with effluent and/or floor washings.\n(ii) Stormwater\n\t\t\t\twithin battery limit of industry shall be channelized through\n\t\t\t\tseparate drain (s) passing through HDPE lined pit(s) each having\n\t\t\t\tholding capacity of 10 minutes (hourly average) of rainfall for\n\t\t\t\tits catchment area",
        "footnote": "",
        "is_definition": false,
        "sort_order": 52
    },
    "prev_section": "71",
    "next_section": "76"
}