    "act_title": "The Environment (Protection) Rules, 1986",
    "act_slug": "the-environment-protection-rules-1986",
    "section_label": "Section",
    "section": {
        "number": "71",
        "title": "71. Pesticides industry (i)\nCompulsory Parameters mg/l except pH pH 6.5-8.5 BOD (3 days at 27 o C) 100 Oil & Grease 10 Suspended solids 100 Bio-assay test Minimum 90%\nsurvival of fish after 96 hours with 90% effluent and 10% dilution water. Test shall be carried out as per IS : 6502-1971. (ii) Additional Parameters mg/l (a) Heavy metal Copper 1.0 Manganese 1.0 Zinc 1.0 Mercury 0.01 Tin 0.1 Any other like Nickel shall not exceed 5 times the drinking water standards (BIS) individually. (b) Organic",
        "chapter": null,
        "content": "Minimum 90%\nsurvival of fish after 96 hours with 90% effluent and 10% dilution water. Test shall be carried out as per IS : 6502-1971.\nshall not exceed 5 times the drinking water standards (BIS) individually.\nNote.\n(2) From the \"Additional Parameters\" specified in 71 (ii), only the relevant parameters (based on the raw-materials used and products manufactured) may be the concerned State Board on a case-to-case basis .\n(3) No limit for COD is prescribed. If the COD in a treated effluent is persistently more than 250 mg/l, such industrial units are required to identify the chemicals causing the same. In case, there are found to be toxic as defined in Schedule I of the Hazardous Chemicals Rules, 1989, the State Boards in such cases may direct the industries to install tertiary treatment, stipulating time-limit. This may be done on a case-to-case basis.\n(4) Solar evaporation followed by incineration is a recognised practice, provide the guidelines of solar evaporation as given below are followed:\n(i) Solar evaporation pans shall be constructed in such a way that the bottom is at least one metre above the ground level.\n(ii) Solar evaporation pans shall be leak proof and construction and designed as per IS: 90.\n(iii) The solar evaporation pans shall be designed on the basis of evaporation rate matching to the out put of waste-water.\n(iv) Waste-water must be pre-treated as below before subjecting to solar evaporation:\n(a) Oil and grease and floating organics shall be removed so that the rate of evaporation is not affected.\n(b) Acidic/Alkaline waste must be neutralised before solar evaporation to maintain pH in the range of 6.5 to 8.5.\n(c) Toxic volatile matter shall be removed so as not to cause air pollution.\n(v) During the rainy season, storm water shall not be allowed to mix with process waste and enter the pans. The waste-water shall in no case outflow from the evaporation pans. Alternative arrangements shall be made to hold the waste-water in proper impervious tanks and if necessary, force evaporated.\n(vi) In no circumstances, the liquid effluent shall be discharged without conforming to the minimal national standards or stored in a holding arrangement which is likely to cause pollution.\n(vii) The sludge from the solar evaporation pans shall be incinerated or disposed as per the guidelines for management and handling of hazardous waste, published by the Ministry of Environment and Forests, Government of India, after obtaining authorisation from the State Pollution Control Board under the Hazardous Wastes (Handling and Management) Rules, 1989.\n(viii) The facility shall be protected from flood and storm to prevent embankments from erosion or any other damage which may render any portion inoperable.\n(ix) Facilities shall be protective enclosure to keep wildlife, domestic animals, unauthorised persons, etc., away.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 51
    },
    "prev_section": "70",
    "next_section": "72"
}