    "act_title": "The Environment (Protection) Rules, 1986",
    "act_slug": "the-environment-protection-rules-1986",
    "section_label": "Section",
    "section": {
        "number": "33",
        "title": "33. Thermal Power\n\t\t\t\t\tPlants",
        "chapter": null,
        "content": "Stack\n\t\t\t\t\tHeight /Limits\nPower generation\n\t\t\t\t\tcapacity:\n- 500 MW and\n\t\t\t\t\tabove\n275\n- 200 MW/210 MW\n\t\t\t\t\tand above to less than 500 MW\n220\n- Less than 200\n\t\t\t\t\tMW /210 MW\nH=14(Q) 0.3 where Q is emission rate of SO 2 in kg/hr. and H Stack\n\t\t\t\t\theight in meters.\nStream generation\n\t\t\t\t\tcapacity:\n- Less than 2\n\t\t\t\t\tton/hr.\n2-1/2 times the\n\t\t\t\t\tneighboring building height or 9 metres (whichever is more).\n- More than 2\n\t\t\t\t\tton/hr. to 5 ton/hr.\n12\n- More than 5\n\t\t\t\t\tton/hr. to 10 ton/hr.\n15\n- More than 10\n\t\t\t\t\tton/hr.\n18\n- More than 15\n\t\t\t\t\tton/hr. to 20 ton/hr.\n15\n- More than 20\n\t\t\t\t\tton/hr. to 25 ton/hr.\n24\n- More than 25\n\t\t\t\t\tton/hr. to 30 ton/hr.\n27\n- More than 30\n\t\t\t\t\tton/hr.\n30 or using\n\t\t\t\t\tformula H=14(Q) 0.3 (whichever is more) where Q is\n\t\t\t\t\temission rate of SO 2 in kg/hr. and H is Stack height\n\t\t\t\t\tin metres.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 32
    },
    "prev_section": "30",
    "next_section": "34"
}