    "act_title": "The Environment (Protection) Rules, 1986",
    "act_slug": "the-environment-protection-rules-1986",
    "section_label": "Section",
    "section": {
        "number": "22",
        "title": "22. Nitric Acid\n\t\t\t\t(emission oxides of nitrogen)",
        "chapter": null,
        "content": "Emission of Oxides\n\t\t\t\tof Nitrogen\n3 kilogramme of\n\t\t\t\toxides of nitrogen per tone of weak acid (before concentration)\n\t\t\t\tproduced\n[23. Sulphuric\n\t\t\t\tAcid Plant]\nEmission standards\nLimiting\n\t\t\t\tconcentration in mg/Nm3, unless started\nPlant capacity for\n\t\t\t\t100% concentration of Sulphuric\nExisting\n\t\t\t\tUnit\nNew\n\t\t\t\tUnit\nAcid (tonne/day)\nSulphur dioxide\n(SO 2 )\n\t\t\t\tup to 300\n1370\n1250\nAbove 300\n1250\n950\nAcid Mist/Sulphur\nUp to 300\n90\n70\nTrioxide\nAbove 300\n70\n50\nNote. - (i)\n\t\t\t\tScrubbing units shall have on-line pH meter with auto recording\n\t\t\t\tfacility.\n(ii) The height of\n\t\t\t\tthe stack emitting sulphur-dioxide or acid mist shall be of\n\t\t\t\tminimum of 30 metre or as per the formula H = 14 (Q) (0.3) (whichever is more).\nWhere \"H\"\n\t\t\t\tis the Height of stack in metre; and \"Q\" is the maximum\n\t\t\t\tquantity of So 2 expected to be emitted through the\n\t\t\t\tstack at 110 per cent rated capacity of the plants and calculated\n\t\t\t\tas per the norms of gaseous emission.\n(iii) Plants\n\t\t\t\thaving more than one stream or unit of sulphuric acid at one\n\t\t\t\tlocation, the combined capacity of all the streams and units\n\t\t\t\tshall be taken into consideration for determining the stack\n\t\t\t\theight and applicability of emission standards.\n(iv) Plants having\n\t\t\t\tseparate stack for gaseous emission for the scrubbing unit, the\n\t\t\t\theight of this stack shall be equal to main stack.]\nS.No.\nIndustry\nParameter\nStandard\n24.\nIntegrated Iron\n\t\t\t\tand Steel Plant\nA-Coke oven\n\t\t\t\t(by-product type)\na. Effluent\n\t\t\t\tStandards\nLimiting\n\t\t\t\tconnecntration in mg/l, except for pH\npH\n6.0-8.50\nSuspended solids\n100\nBOD, 3 days at\n\t\t\t\t27°C\n30\nCOD\n250\nOil and grease\n10\nAmmonical nitrogen\n\t\t\t\tas N\n50\nCyandie (as CN-)\n0.2\nPhenol\n1.0\nb. Emission\n\t\t\t\tStandards\nNew Batteries (at\n\t\t\t\tgreen field site)\nRebuild Batteries\nExisting Batteries\n(i) Fugitive\n\t\t\t\tVisible Emission\nLeakage from door\n5(PLD)*\n10(PLD)*\n10(PLD)*\nLeakage from\n\t\t\t\tcharging lids\n1(PLL)**\n1(PLL)**\n1(PLL)**\nLeakage from AP\n\t\t\t\tCovers\n4(PLO)+\n4(PLO)+\n4(PLO)+\nCharging emission\n\t\t\t\t(Second/charge)\n16(with HPLA)\n50(with HPLA)\n75\n*PLD- Percent\n\t\t\t\tleaking doors; **PLL-Percent leaking lids;\n+PLO- Percent\n\t\t\t\tLeaking off takes and HPLA- Aspiration through high pressure\n\t\t\t\tliquor injection in gooseneck.\n(ii) (Stack\n\t\t\t\tEmission Standards)\nSO2 (mg/Nm3)\n800\n800\n800\nNOx (mg/Nm3)\n500\n500\n500\nParticulate matter\n\t\t\t\t(mg/Nm3)\n50\n50\n50\nParticulate matter\n\t\t\t\tduring charging of stamp charging batteries (mg/Nm3)\n25\n25\n25\nSulphur in COke\n\t\t\t\tOven gas used for heating (mg/Nm3)\n800\n-\n-\n(iii) Fugitive\n\t\t\t\tEmission: Benzo (a) Pyrene (BaP)\nBattery area (top\n\t\t\t\tof the battery)(µg/m3)\n5\n5\n5\nOther units in\n\t\t\t\tCoke oven plant (µg/m3)\n2\n2\n2\nB.-Sintering Plant\na. Effluent\n\t\t\t\tStandards\nLimiting\n\t\t\t\tconcentration in mg/l, except of pH\npH\n6.0-8.50\nSuspended solids\n100\nOil and grease\n10\nb. Emission\n\t\t\t\tStandards\nParticulate matter\n\t\t\t\t(mg/Nm3)\n150\nC.- Blast Furance\na. Effluent\n\t\t\t\tStandards\nLimiting\n\t\t\t\tconcentration in mg/l, except for pH\npH\n6.0-805\nSuspended solids\n\t\t\t\t(mg/l)\n50\nOil and grease\n\t\t\t\t(mg/l)\n10\nCyanide as CN\n\t\t\t\t(mg/l)\n0.2\nAmmonical Nitrogen\n50\nas NH3-N (mg/l)\nb. Emission\n\t\t\t\tStandards\n(i) Stack\n\t\t\t\tEmissions\nNew\n\t\t\t\tUnits\nExisting\n\t\t\t\tUnits\nBF Stove\nParticulate matter\n\t\t\t\t(mg/Nm3)\n50\n30\nSO2 (mg/Nm3)\n250\n200\nNox (mg/Nm3)\n150\n150\nCO (Vol/Vol)\n1%\n\t\t\t\t(max)\n1%\n\t\t\t\t(max)\n(ii) Space\n\t\t\t\tDeducting/Other Stacks of BF area\nParticulate matter\n\t\t\t\t(mg/Nm3)\n100\n50\n(iii) Fugitive\n\t\t\t\tEmission\nExisting\n\t\t\t\tUnits\nNew\n\t\t\t\tUnits\nParticulate matter\n\t\t\t\t(Size less than 10 microns) PM10 (µg/m3)\n4000\n3000\nSO2 (µg/m3)\n200\n150\nNOx (µg/m3)\n150\n120\nCarbon monoxide\n\t\t\t\t(µg/m3)- 8 hours\n5000\n5000\n1hours\n10,000\n10,000\nLead, as Pb in\n\t\t\t\tfugitive dust (µg/m3) at Cast House\n2\n2\nD.- Steel Making\n\t\t\t\tShop-Basic Oxygen Furnace\na. Effluent\n\t\t\t\tStandards\npH (mg/l)\n6.0-8.5\nSuspended solids\n\t\t\t\t(mg/l)\n100\nOil and grease\n\t\t\t\t(mg/l)\n10\n(i) Stack Emission\nExisting Units\nNew Units\nConverters\nParticulate matter\n\t\t\t\t(mg/Nm3)\n- Blowing/Lancing\n\t\t\t\toperation\n300\nShould be with gas\n\t\t\t\trecovery\n- Normal operation\n150\nShould be with gas\n\t\t\t\trecovery\n**Secondary\n\t\t\t\tFmission Stack : De-dusting of de-sulphurisation, Secondary\n\t\t\t\trefining etc.\nParticulate matter\n\t\t\t\t(mg/Nm3)\n100\n50\n(ii) Fugitive\n\t\t\t\tEmission\nExisting\n\t\t\t\tUnits\nNew\n\t\t\t\tUnits\nParticulate matter\n\t\t\t\t(size less than 10 microns) PM10 (µg/m3)\n4000\n3000\nSO2 (µg/m3)\n200\n150\nNOx (µg/m3)\n\t\t\t\t- 8 hours\n5,000\n5,000\n1 hours\n10,000\n10,000\nLead, as Pb in\n\t\t\t\tdust at Converter floor (µg/m3)\n2\n2\nE- Rolling Mills\na. Effluent\n\t\t\t\tStandaeds\npH\n6.0-9.0\nSuspended solids\n\t\t\t\t(mg/l)\n100\nOil and grease\n\t\t\t\t(mg/l)\n10\nb. Emission\n\t\t\t\tStandards\nParticulate matter\n\t\t\t\t(mg/Nm3)\n150\nRe-Heating\nSensitive\n\t\t\t\tarea\nOther\n\t\t\t\tarea\nParticulate matter\n\t\t\t\t(mg/Nm3)\n150\n250\nF.- Arc Furnaces\nEmission Standards\nParticulate matter\n\t\t\t\t(mg/Nm3)\n150\nG.- Induction\n\t\t\t\tFurnaces\nEmission Standards\nParticulate matter\n\t\t\t\t(mg/Nm3)\n150\nH.- Cupola\n\t\t\t\tFoundary\nEmission Standards\nmelting capacity\n\t\t\t\tless than 3 tonne/hr\nmelting capacity 3\n\t\t\t\ttonne/hr and above\nParticulate matter\n\t\t\t\t(mg/Nm3)\n450\n150\nSO2 (mg/Nm3)\n300, corrected at\n\t\t\t\t12% CO2\nI.- Calcination\n\t\t\t\tPlant/Lime Kiln/Dolomite Kiln\nEmission Standards\ncapacity upto\n\t\t\t\t40t/day\ncapacity above\n\t\t\t\t40t/dat\nParticulate matter\n\t\t\t\t(mg/Nm3)\n500\n150\nJ.- Refractory\n\t\t\t\tUnit\nEmission Standards\nParticulate matter\n\t\t\t\t(mg/Nm3)\n150\nNote : 1.\n\t\t\t\tThe height of the each process stack shall be a minimum of 30\n\t\t\t\tmetres or as per the formula H = 14(W)0.3 (Whichever is more),\n\t\t\t\twhere \"H\" is the height of stack in metre; and \"Q\"\n\t\t\t\tis the maximum quantity of SO2 in kg/hr expected to be emitted\n\t\t\t\tthrough the stack at rated capacity of the plant(s) and\n\t\t\t\tcalculated as per the norms of faseous emission. 2. The Plants\n\t\t\t\thaving separate stack for gaseous emission for the scrubbing\n\t\t\t\tunit, the height of this stack shall be equal to main stack of\n\t\t\t\tthe plant or 30 metres, whichever is higher. 3. It is essential\n\t\t\t\tthat stack constructed over the cupola beyond the charging door\n\t\t\t\tand emissions shall be directed through the stack which should be\n\t\t\t\tat least six times the diameter of cupola. 4. In respect of\n\t\t\t\tArc Furnaces and induction Furnaces provision shall be made for\n\t\t\t\tcollecting the fumes before discharging the emissions through the\n\t\t\t\tstack. 5. Foundries shall install scrubber, followed by a\n\t\t\t\tstack of height atleast six times the diameter of the Cupola\n\t\t\t\tbeyond the charing door. 6.Recovery type converters shall be\n\t\t\t\tinstalled in new plants or expansion projects.\nNote :\nNote: (i)\n\t\t\t\tStromwater shall not be allowed to mix with effluent, scrubber\n\t\t\t\twater and/or floor washings. (ii) Stormwater shall be\n\t\t\t\tchannellized through separate drains as per natural gradient,\n\t\t\t\tpassing through High Density Polyethlene (HDPE) lined pits, each\n\t\t\t\thaving holding capacity of 10 minutes (hourly average) of\n\t\t\t\trainfall.\nNote:\n[25. Thermal Power\n\t\t\t\tPlants]\nParticulate Malter\n\t\t\t\tEmissions :\n-generation\n\t\t\t\tcapacity 210 MW or more\n150 milligramme\n\t\t\t\tper normal cubic meter\n-generation\n\t\t\t\tcapacity less than 210 MW\n350 milligramme\n\t\t\t\tper normal cubic meter\n*Depending upon the requirement of local situation, such as protected area, the State Pollution Control Boards and other implementing agencies under the Environment (Protection) Act, 1986, may prescribe a limit of 150 milligramme per normal cubic metre, irrespective of generation capacity of the plant.\n26. [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [27. All types of Asbestos manufacturing units (including all processes involving the use of Asbestos)] Emissions [-Pure Asbestos material 0.5 fibre */cc for one year from the date of notification 0.2 fibre */cc after one year from the date of notification] -Total dust 4 Fibre */cc 2 mg/m 3 (normal) 28. Chlor Alkali (Caustic soda) Emissions Concentrations in mg/m 3 (normal) (a) mercury Cell Mercury (from hydrogen gas holder stack) 0.2 (b) All processes Chlorine (from hypo tower) 15.0 (c) All processes Hydrochloric acid vapours and mist\n(from hydrochloric acid plant) 35.0 29. Large pulp and paper Emissions Concentrations in mg/m 3 (normal) Particulale matter 250** H 2 S 10",
        "footnote": "",
        "is_definition": false,
        "sort_order": 30
    },
    "prev_section": "20",
    "next_section": "30"
}