{
    "act_title": "The Environment (Protection) Rules, 1986",
    "act_slug": "the-environment-protection-rules-1986",
    "section_label": "Section",
    "section": {
        "number": "11",
        "title": "11. Manner of giving notice.",
        "chapter": null,
        "content": "(a) if the alleged offence has taken place in a Union territory:-\n(A) the Central Board; and\n(B) the Ministry of Environment and Forests (represented by the Secretary of the Government of India);\n(b) if the alleged offence has taken place in a State:-\n(A) the State Board; and\n(B) the Government of the State (represented by the Secretary to the State Government incharge of environment); and\n(C) the Ministry of Environment and Forests (represented by the Secretary to the Government of India);\n[12. Furnishing of information to authorities and agencies in certain cases.\n(i) The officer-in-charge of emergency or disaster relief operations in a district or other region of a State or Union territory specified by whatever designation, by the Government of the said State or Union territory, and in whose jurisdiction the industry, process or operation is located.\n(ii) The Central Board or a State Board, as the case may be, and its regional officer having local jurisdiction who have been delegated powers under sections 20, 21, 23 of the Water (Prevention and Control of Pollution) Act, 1974 (6 of 1974) and section 24 of the Air (Prevention and Control of Pollution) Act, 1981 (14 of 1981).\n(iii) The statutory authorities or agencies specified in column 3 in relation to places mentioned in column 2 against thereof of [Schedule V]\n[13. Prohibition and restriction on the handling of hazardous substances in different areas.\n(i) the hazardous nature of the substance (either in qualitative or quantitative terms) as far as may be in terms of its damage causing potential to the environment, human beings, other living creatures, plants and property;\n(ii) the substances that may be or likely to be readily available as substitutes for the substances proposed to be prohibited or restricted;\n(iii) the indigenous availability of the substitute, or the state of technology available in the country for developing a safe substitute;\n(iv) the gestation period that may be necessary for gradual introduction of a new substitute with a view to bringing about a total prohibition of the hazardous substance in question; and\n(v) any other factor as may be considered by the Central Government to be relevant to the protection of environment.\n(i) Whenever it appears to the Central Government that it is expedient to impose prohibition or restriction on the handling of hazardous substances in an area, it may, by notification in the Official Gazette and in such other manner as the Central Government may deem necessary from time to time, give notice of its intention to do so.\n(ii) Every notification under clause (i) shall give a brief description of the hazardous substances and the geographical region or the area to which such notification pertains and also specify the reasons for the imposition of prohibition or restriction on the handling of such hazardous substances in that region or area.\n(iii) Any person interested in filing an objection against the imposition of prohibition or restrictions on the handling of hazardous substances as notified under clause (i) may do so in writing to the Central Government within thirty days from the date of publication of the notification in the Official Gazette.\n(iv) The Central Government shall within a period of sixty days from the date of publication of the notification in the Official Gazette consider all the objections received against such notification and may impose prohibition or restrictions on the handling of hazardous substances in a region or an area.]\n[14. Submission of environment statement.\nSCHEDULE [I]\n( See rule 3 )\nSl . No. Industry Parameter Standards 1 2 3 4 1. Caustic soda industry Concentration not to exceed, milligramme per litre (except for pH and flow) Total concentration of mercury in the final effluent* 0.01 Mercury bearing waste-water generation (flow) 10 kilolitres/tonne of caustic soda produced pH 5.5\n- 9.0 *Final effluent is the combined effluent from (a) cell house, (b) brine plant, (c) chlorine handling, (d)\nhydrogen handling, (e) hydrochloric acid plant 2. Man-made fibres\n(synthetic) Concentration not to exceed, milligramme per litre (except for pH) Suspended solids 100 [BOD (3 days at 27 [°] C)] 30 Petroleum Oil refinery pH 5.5-9.0 [3.] [ A.\nEffluent ] [Limiting value for concentration (mg/I except for pH)] [1. pH] [6.0-8.5] [2. Oil & Grease] [5.0] [3. BOD 3 days, 27°C] [15.0] [4. COD] [125.0] [5. Suspended Solids] [20.0] [6. Phenols] [0.35] [7. Sulphide] [0.5] [8. CN] [0.20] [9. Ammonia as N] [15.0] [10. TKN] [40.0] [11. P] [3.0] [12. Cr (Hexavalent)] [0.1] [13. Cr (Total)] [2.0] [14. Pb] [0.1] [15. Hg] [0.01] [16. Zn] [5.0] [17. Ni] [1.0] [18. Cu] [1.0] [19. V] [0.2] [20. Benzene] [0.1] [21. Benzo\n(a)-Pyrene] [0.2] [Notes. - ] [(i)\nConcentration limits shall be complied with at the outlet, discharging effluent (excluding discharge from sea water cooling systems) to receiving environment (surface water bodies, marine systems or public sewers). In case of application of treated effluent directly for irrigation/horticulture purposes (within or outside the premises of refinery), make-up water for cooling systems, fire fighting, etc., the concentration limits shall also be complied with at the outlet before taking the effluent for such application.\nHowever, any use in the process such as use of sour water in desolater is excluded for the purpose of compliance.] [(ii) In case of circulating seawater cooling, the blow-down from cooling systems shall be monitored for pH and oil\n& grease (also hexavalent & total chromium, if chromate treatment is given to cooling water) and shall conform to the concentration limits for these parameters. In case of reuse of treated effluent as cooling water make-up, all the parameters (as applicable for treated effluent) shall be monitored and conform to the prescribed standards.] [(iii) In case of once through cooling with seawater, the oil & grease content in the effluent from cooling water shall not exceed 1.0 mg/1]\nSl . No.\nSl\n. No.\nIndustry\nIndustry\nParameter\nParameter\nStandards\nStandards\n1\n1\n2\n2\n3\n3\n4\n4\n1.\n0.01\n5.5\n- 9.0\n2.\n100\n30\n5.5-9.0\n[3.]\n[ A.\nEffluent ]\nA.\nEffluent\n[Limiting value for concentration (mg/I except for pH)]\n[6.0-8.5]\n[5.0]\n[15.0]\n[125.0]\n[20.0]\n[0.35]\n[0.5]\n[0.20]\n[15.0]\n[40.0]\n[3.0]\n[0.1]\n[2.0]\n[0.1]\n[0.01]\n[5.0]\n[1.0]\n[1.0]\n[0.2]\n[0.1]\n[0.2]\n[Notes. - ]\n[B. Emissions Limiting concentration in mg/Nm, unless stated Fuel Type Existing refineries New Refinery/Furnace/Boiler (Furnace, Boiler and captive Power Plant) Sulphur Dioxide (SO 2 ) Gas 50 50 Liquid 1700 850 Oxides of Nitrogen (NO x ) Gas 350 250 Liquid 450 350 Particulate Matter (PM) Gas 10 5 Liquid 100 50 Carbon Monoxide (CO) Gas 150 100 Liquid 200 150 Nickel and Vanadium (Ni+V) Liquid 5 5 Hydrogen Sulphide\n(H 2 S) in fuel gas Liquid/gas 150 150 Sulphur content in liquid fuel, weight % Liquid/gas 1.0 0.5 Notes. - (i) In case of mixed fuel (gas and liquid) use, the limit shall be computed based on heat supplied by gas and liquid fuels. (ii) All the furnaces/boilers with heat input of 10 million kilo calories/hour or more shall have continuous systems for monitoring of SO\u00142\u0014, and NOx. Manual monitoring for all the emission parameters in such furnaces or boilers shall be carried out once in two months. (iii) All the emission parameters in furnaces/boilers having heat input less than 10\nmillion kilo calories/hour will be monitored once in three months. (iv) In case of continuous monitoring, one hourly average concentration values shall be complied with 98% of the time in a month. Any concentration value obtained through manual monitoring, if exceeds the limiting concentration value, shall be considered as non-compliance. (v) Data on Nickel and Vanadium content in the liquid fuel (in ppm)\nshall be reported. Nickel and Vanadium in the liquid fuel shall be monitored at least once in six months, if liquid fuel source & quality are not changed. In case of changes, measurement is necessary after every change.\n[B. Emissions\n[B. Emissions\nLimiting concentration in mg/Nm, unless stated\nLimiting concentration in mg/Nm, unless stated\nFuel Type\nFuel Type\nExisting refineries\nExisting refineries\nNew Refinery/Furnace/Boiler\nNew Refinery/Furnace/Boiler\n50\n50\n1700\n850\n350\n250\n450\n350\n10\n5\n100\n50\n150\n100\n200\n150\n5\n5\n150\n150\n1.0\n0.5\nNotes. -\n(ii) All the furnaces/boilers with heat input of 10 million kilo calories/hour or more shall have continuous systems for monitoring of SO\u00142\u0014, and NOx. Manual monitoring for all the emission parameters in such furnaces or boilers shall be carried out once in two months.\n(iii) All the emission parameters in furnaces/boilers having heat input less than 10\nmillion kilo calories/hour will be monitored once in three months.\n(iv) In case of continuous monitoring, one hourly average concentration values shall be complied with 98% of the time in a month. Any concentration value obtained through manual monitoring, if exceeds the limiting concentration value, shall be considered as non-compliance.\n(v) Data on Nickel and Vanadium content in the liquid fuel (in ppm)\nshall be reported. Nickel and Vanadium in the liquid fuel shall be monitored at least once in six months, if liquid fuel source & quality are not changed. In case of changes, measurement is necessary after every change.\n(FCC Regenerators) Limiting concentration in mg/Nm³, unless stated Existing refineries hydro-processed FCC feed Other than hydro-processed FCC feed New Refinery/FCC Commissioned Sulphur Dioxide (SO 2 ) 500 1700 500\n(for hydro-processed feed) 850 (for other feed) Oxides of Nitrogen (NO x ) 400 450 350 Particulate Matter (PM) 100 100 50 Carbon Monoxide (CO) 400 400 300 Nickel and Vanadium(Ni+V) 2 5 2 Opacity, % 30 30 30 Notes. - (i) In case part feed is hydro-processed, the emission values shall be calculated proportional to the feed rates of untreated and treated feeds. (ii) FCC regenerators shall have continuous systems for monitoring of SO\u00142\u0014 and NOx. One hourly average concentration values shall be complied with 98% of the time in a month, in case of continuous monitoring. Manual monitoring for all the emission parameters shall be carried out once in two months. (iii) Any concentration value obtained through manual monitoring, if exceeds the limiting concentration value, shall he considered as non-compliance. (iv) Data on Sulphur (weight in %), Nickel (PPM) and Vanadium (PPM) content in the feed to FCC shall be reported regularly. (v) Limit of Carbon Monoxide emissions shall be complied with except during annual shut down of CO boiler for statutory maintenance.\nLimiting concentration in mg/Nm³, unless stated\nLimiting concentration in mg/Nm³, unless stated\nExisting refineries hydro-processed FCC feed\nExisting refineries hydro-processed FCC feed\nOther than hydro-processed FCC feed\nOther than hydro-processed FCC feed\nNew Refinery/FCC Commissioned\nNew Refinery/FCC Commissioned\n500\n1700\n500\n(for hydro-processed feed) 850 (for other feed)\n400\n450\n350\n100\n100\n50\n400\n400\n300\n2\n5\n2\n30\n30\n30\nNotes. -\n(i) In case part feed is hydro-processed, the emission values shall be calculated proportional to the feed rates of untreated and treated feeds.\n(ii) FCC regenerators shall have continuous systems for monitoring of SO\u00142\u0014 and NOx. One hourly average concentration values shall be complied with 98% of the time in a month, in case of continuous monitoring. Manual monitoring for all the emission parameters shall be carried out once in two months.\n(iii) Any concentration value obtained through manual monitoring, if exceeds the limiting concentration value, shall he considered as non-compliance.\n(iv) Data on Sulphur (weight in %), Nickel (PPM) and Vanadium (PPM) content in the feed to FCC shall be reported regularly.\n(v) Limit of Carbon Monoxide emissions shall be complied with except during annual shut down of CO boiler for statutory maintenance.\nPlant capacity Existing SRU New SRU or Refinery Commissioned (Tonnes/day) [Sulphur recovery Units (SRU)] Sulphur recovery, % Above 20 98.7 99.5 H 2 S mg/Nm 3 , 15 10 Sulphur recovery, % 5-20 96 98 Sulphur recovery, % 1-5 94 96 Oxides of Nitrogen NOx), mg/Nm 3 Allcapacity 350 250 Carbon Monoxide (CO), mg/Nm 3 All capacity 150 100 Notes. - (i) Sulphur recovery units having capacity above 20 tonnes per day shall have continuous systems for monitoring of SO 2 . Manual monitoring for all the emission parameters shall be carried out once in a month. (ii) Data on Sulphur Dioxide emissions (mg/Nm 3 ) shall he reported regularly. (iii) Sulphur recovery efficiency shall be calculated on monthly basis, using quantity of sulphur in the feed to SRU and quantity of sulphur recovered.\nPlant capacity\nPlant capacity\nExisting SRU\nExisting SRU\nNew SRU or Refinery Commissioned\nNew SRU or Refinery Commissioned\n(Tonnes/day)\n(Tonnes/day)\n98.7\n99.5\n15\n10\n96\n98\n94\n96\n350\n250\n150\n100\nNotes. -\nC. Fugitive Emission\nC. Fugitive Emission\n(i)(a) IFRT and EFRT shall be provided with double seals with minimum vapour recovery of 96%.\n(b) Primary seal shall be liquid or shoe mounted for EFRT and vapour mounted for IFRT. Maximum seal gap width will be 4 cm and maximum gap area will be 200 cm²/m of tank diameter.\n(c) Secondary seal shall be rim mounted. Maximum seal gap width will be 1.3 cm and maximum gap area will be 20 cm²/m of tank diameter.\n(d) Material of seal and construction shall ensure high performance and durability.\n(ii) Fixed Roof Tanks shall have vapour control efficiency of 95% and vapour balancing efficiency of 90%.\n(iii) Inspection and maintenance of storage tanks shall be carried out under strict control. For the inspection, API RP 575 may be adopted. In-service inspection with regard seal gap should be carried out once in every six months and repair to be implemented in short time. In future, possibility of on-stream repair of both seals shall be examined.\nStorage of Volatile Liquids: Benzene Storage\nStorage of Volatile Liquids: Benzene Storage\n1 2 3 4 Emission control for Road Tank Truck/\nRail Tank Wagon Loading Loading of Volatile Products Gasoline and Naphtha: (i) VOC reduction, % (i) 99.5 (ii) Emission, gm/m 3 (ii) 5 Benzene: (i) VOC reduction, % (i) 99.99 (ii) Emission, mg/m 3 (ii) 20 Toluee/Xylene\n1\n1\n2\n2\n3\n3\n4\n4\n(i)\n99.5\n(ii)\n5\n(i)\n99.99\n(ii)\n20\n(i)\n99.98\n(ii)\n150\nNote. -\nStandards for Equipment Leaks\nStandards for Equipment Leaks\nComponent General Hydrocarbon (ppm) Benzene (ppm) Till 31st Dec., 2008 w.e.f. January 01, 2009 Till 31st Dec., 2008 w.e.f. January 01, 2009 Pump/Compressor 10000 5000 3000 2000 Valves/Flanges 10000 3000 2000 1000 sOther components 10000 3000 2000 1000\nComponent\nComponent\nGeneral Hydrocarbon (ppm)\nGeneral Hydrocarbon (ppm)\nBenzene (ppm)\nBenzene (ppm)\nTill 31st Dec., 2008\nTill 31st Dec., 2008\nw.e.f. January 01, 2009\nw.e.f. January 01, 2009\nTill 31st Dec., 2008\nTill 31st Dec., 2008\nw.e.f. January 01, 2009\nw.e.f. January 01, 2009\n10000\n5000\n3000\n2000\n10000\n3000\n2000\n1000\n10000\n3000\n2000\n1000\n(7) Monitoring Requirements and Repair Schedule: Following frequency of monitoring of leaks and schedule for repair of leaks shall be followed: Component Frequency of monitoring Repair schedule Quarterly\n(semiannual after two consecutive periods with < 2% leaks and annual after 5 periods with < 2% leaks) Repair will be started within 5 working days and shall be completed within 15 working days after detection of leak for general hydrocarbons. In case of benzene, the leak shall be attended immediately for repair. Pump seals Quarterly Compressor seals Quarterly Pressure relief devices Quarterly Pressure relief devices (after venting) Within 24 hours Heat Exchangers Quarterly Process drains Annually Components that are difficult to monitor Annually Pump seals with visible liquid dripping Immediately Immediately Any component with visible leaks Immediately Immediately Any component after repair/\nreplacement Within five days\nComponent\nFrequency of monitoring\nFrequency of monitoring\nRepair schedule\nRepair schedule\nQuarterly\n(semiannual after two consecutive periods with < 2% leaks and annual after 5 periods with < 2% leaks)\nRepair will be started within 5 working days and shall be completed within 15 working days after detection of leak for general hydrocarbons. In case of benzene, the leak shall be attended immediately for repair.\nD. Emission Standards for VOC from Wastewater Collection and Treatment\nD. Emission Standards for VOC from Wastewater Collection and Treatment\n[4. Sugar industry Effluents All concentration values are in milligramme per litre except for pH pH 5.5 - 8.5 Total Suspended Solids (TSS), milligramme per litre 100 (for disposal on land) 30 (for disposal in surface waters) Biological Oxygen Demand, BOD [3 days at 27 0 C], milligramme per litre 30 (for disposal in surface waters) Oil & Grease milligramme per litre 10 Total Dissolved Solids (TDS), milligramme per litre 2100 Final waste-water discharge limit 200 litre per tonne of cane crushed (Final treated effluent discharge restricted to 100 litre per tonne of cane crushed and Wast water from spray pond overflow or cooling tower blow down to be restricted to 100 litre per tonne of cane crushed and only single outlet point form unit is allowed.) Emissions The particulate matter emissions from the stack shall be less than 150 milligramme per normal cubic metre]\n(i) Loading rates for different soil textures\nS.N\nSoil Texture\nLoading rate in m3/Ha/Day\n1\nSandy\n225 to 280\n2\nSandy loam\n170 to 225\n3\nLoam\n110 to 170\n4\nClay loam\n55 to 110\n5\nClay\n35 to 55\n(ii) Waste water conservation and pollution control management",
        "footnote": "",
        "is_definition": false,
        "sort_order": 9
    },
    "prev_section": "10",
    "next_section": "1"
}