    "act_title": "The Dedicated Freight Corridor Railway General Rules, 2018",
    "act_slug": "the-dedicated-freight-corridor-railway-general-rules-2018",
    "section_label": "Section",
    "section": {
        "number": "273",
        "title": "273. Interlocking of Level Crossing Gates, approach train warning and track locking.",
        "chapter": null,
        "content": "(b) the gate signals shall remain 'ON' and attain \"OFF' aspect only when the gate is closed and is so detected by interlocking;\n(c) each gate shall have road signals as well as hooter alarm to warn road users of closing of the gate;\n(d) the road signal shall show a steady yellow when barrier is lifted and steady red when closed towards the road users.\n(b) a separate panel for the operation of booms through push buttons shall be provided for raising or lowering of booms as also for stopping it mid-way during operations; and\n(c) separate Telephone shall be provided between Gateman and station master of block stations on either side; wherever the Level Crossing Gate is common to Indian Railway and Dedicated Freight Corridor Railway lines, separate telephones shall be provided between Gateman and station masters on either side of both Dedicated Freight Corridor Railway and Indian Railway stations.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 273
    },
    "prev_section": "272",
    "next_section": "274"
}