        "content": "(a) the bucket or other means of conveyance, when used for lowering or raising persons, shall be provided with sufficient cover overhead for protection from things falling down the shaft; and\n(b) there shall be provided for each bucket or other means of conveyance, a sufficient number of guides which shall be kept extended to within 22.5 metres of the shaft bottom at all times when sinking is in progress:\n(i) two separate means of interchanging distinct and definite signals between the bottom and the top of the shaft; and\n(ii) efficient means for transmitting such signals from the top of the shaft to the winding engineman.\n(b) The signaling appliances shall be examined by a competent person once at least in every twentyfour hours and the result of every such examination shall be recorded in a bound paged book kept for the purpose and shall be signed and dated by the person making the examination.\n(c) Except with the permission in writing of the Chief Inspector and subject to such conditions as he may specify therein, the following code of signals shall be used and observed in signaling-\nOne\nRap Stop\nwhen engine in motion\nOne\nRap Take Up Slack\nwhen engine at rest.\nOne\nRap Raise Slowly\nTwo Raps\nLower\nThree Raps\nTake Up Slack\nwhen men are riding:\n(d) A printed copy of the code of signals, including additional signals, if any, shall be posted prominently at the top of the shaft and also in the winding engine room.\n(e) Except while riding in a bucket or other means of conveyance, no person other than the person authorised in writing by the manager, shall give any signal.\n(b) Where the shaft exceeds 45 meters in depth, the persons working at the bottom of the shaft shall also be protected by an adequate protective covering, extending over the whole area of the shaft which shall be provided with a door for the passage of the bucket or other means of conveyance, to be kept lowered to within 22.5 metres of the bottom of the shaft at all times when sinking is in progress:\n(i) the bucket is properly loaded;\n(ii) materials are not loaded above the rim;\n(iii) long timber, pipes, rails, tools or other material with ends projecting over the rim are securely fastened to the rope, chains or bow; and\n(iv) the bucket, before being sent away, is steadied, and the bottom and sides thereof are free from adhering material.\n(i) the scaffold or platform shall be secured to the sides of the shaft in order to prevent it from swinging;\n(ii) the opening for the passage of the bucket or other means of conveyance, shall be so protected as effectively to prevent anything falling through it;\n(iii) the scaffold or platform shall not be lowered or raised except under the order of the authorised person or other competent person.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 83
    },
    "prev_section": "83",
    "next_section": "85"
}