    "act_title": "The Coal Mines Regulations, 2017",
    "act_slug": "the-coal-mines-regulations-2017",
    "section_label": "Section",
    "section": {
        "number": "166",
        "title": "166. Precautions against inflammable and noxious gases.",
        "chapter": null,
        "content": "(i) by a methane detector to be 0.1 per cent. or more in case of mine having degree one gassy seams;\n(ii) by a methane detector to be 0.5 per cent. or more in case of mine having degree two seams;\n(iii) by the lowered flame of a flame safety lamp or, where methane detectors are used, they indicate one and a quarter per cent. or more of inflammable gas in case of mine having degree three gassy seams.\n(a) all persons shall be withdrawn from the place;\n(b) the place shall be immediately fenced off so as to prevent persons inadvertently entering the same, and the competent person in charge shall, without delay, take steps to remove the gas by improving the ventilation.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 165
    },
    "prev_section": "165",
    "next_section": "167"
}