    "act_title": "The Coal Mines Regulations, 2011",
    "act_slug": "the-coal-mines-regulations-2011",
    "section_label": "Section",
    "section": {
        "number": "170",
        "title": "170. Precautions against inflammable and noxious gases.",
        "chapter": null,
        "content": "(i) when it is indicated by a methane detector to be 0.1% or more in case of mine having only degree one gassy seams;\n(ii) when it is indicated by a methane detector to be 0.5% or more in case of mine having degree two seams; and\n(iii) when with the lowered flame of a flame safety lamp or, where methane indicators are used, they indicate one and a quarter percent, or more of inflammable gas in case of mine having only degree three gassy seams.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 169
    },
    "prev_section": "169",
    "next_section": "171"
}