    "act_title": "The Coal Mines Regulations, 2011",
    "act_slug": "the-coal-mines-regulations-2011",
    "section_label": "Section",
    "section": {
        "number": "163",
        "title": "163. Velocity of air current.",
        "chapter": null,
        "content": "Table\nDegree of gassiness\nPlace where velocity of air is to be measured\nVelocity of air\n1\n2\n3\nFirst, Second or Third degree\nImmediate outbye ventilation connection from the face\n30\nFirst or Second degree\n(i) 4.5 metres from any face\n\t\t\t\twhether working or discontinued on the intake side of the\n\t\t\t\tbrattice or partition;\n(ii) 7.5 metres outbye of the\n\t\t\t\tdischarge end of an air pipe;\n(iii) at the maximum span of a longwall face.\n30\n15\n60\nThird degree\n(i) 4.5 metres from any face\n\t\t\t\twhether working or discontinued on the intake side of the\n\t\t\t\tbrattice or partition;\n(ii) 7.5 metres outbye of the\n\t\t\t\tdischarge end of an air pipe;\n(iii) at the maximum span of a longwall face:\n45\n25\n75",
        "footnote": "",
        "is_definition": false,
        "sort_order": 162
    },
    "prev_section": "162",
    "next_section": "164"
}