    "act_title": "The Bombay Lifts Rules, 1958",
    "act_slug": "the-bombay-lifts-rules-1958",
    "section_label": "Section",
    "section": {
        "number": "28",
        "title": "28. Ultimate or Final Limit Switches.",
        "chapter": null,
        "content": "(b) Ultimate or final limit switches shall act to prevent movement of the lift-car under power, in both directions of travel and shall, after operating, remain open until the lift-car has been moved by hand winding to a position within the limits of normal travel.\n(c) Ultimate or final limit switches shall be operated by the movement of the lift-car in the lift-well; they shall not be mounted on the lift-car.\n(d) Every lift having drum machine shall have two final limit switches, one being operated by the machine and the other by the movement of the lift-car.\n(e) Ultimate or final limit switches shall not control the same relay switches on the controller as the terminal limit switches unless two or more separate and independent relay switches on the controller are provided, two of which shall be closed to complete the motor and brake circuit in each direction of travel. When the ultimate or final limit switches control the same relay switch or switches on the controller as the operating device, or the terminal limit switches, they shall be connected in the control circuit on opposite sides to the terminal limit switches.\n(f) Ultimate limit switches designed to open the main circuit of the motor may control the same switch or switches on the controller as the terminal limit switches, but when such ultimate limit switches are employed on direct current power supplies, they shall be provided with additional contacts to control the brake circuit.\n(g) The contacts of all final or ultimate limit switches shall be opened positively and mechanically by the movement of the lift-car. The cam or cams for operating the limit switches shall be of metal.\n(h) The terminal and the ultimate or final limit switches shall be held in open position when the lift-car is in contact with the overhead structure or resting on the fully compressed buffers.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 35
    },
    "prev_section": "27",
    "next_section": "29"
}