    "act_title": "The Assam Excise Rules, 2016",
    "act_slug": "the-assam-excise-rules-2016",
    "section_label": "Section",
    "section": {
        "number": "216",
        "title": "216. Packing of instruments.",
        "chapter": null,
        "content": "I. Brass hydrometers -\nBrass hydrometers\n(a) in the case of brass instruments with detachable weights, these should be wrapped up in tissue papers and made into a separate packet;\n(b) a sufficient amount of cotton, wool or soft paper should be placed over the instrument in the case to prevent any risk or displacement in transit;\n(c) the case should then be packed in a wooden or tin box. The space between this outer case and the instrument box should be sufficiently packed with paper, shaving, sawdust or other suitable elastic package;\n(d) in the case of brass instruments, the packet containing the weights should be placed in the space between the outer and inner cases;\n(e) the thermometer must be packed separately in a tin cylinder as described under II. Glass hydrometers -  Each stem should be packed in a separate cylindrical tin case whose diameter is aboue 2.54 cm greater than the width of the hydrometer bulb; and at least 2.54 cm longer than the hydrometer stem- (a) the tin case should first have some cotton wool placed in it to a depth of 2.54 cm. (b) the hydrometer should then be gently placed in the case, bulb uppermost (not pushed down through the cotton wool to the foot of the case); (c) it should then be thoroughly packed round with dry sawdust, not rammed too rightly, allowing equal distance all round between the bulb and case; (d) the case should then be filled with sawdust to within 1.27 cm of the top. The remaining 1.27 cm should be filled with cotton wool; (e) the cap should then be put on without undue force and securely fastened. A loose cap should not be used. III. The tin case should then be packed in a wooden box large enough to allow each case having a good layer of sawdust to separate it - (a) from neighboring tins; and (b) from the sides and ends of the box. IV. The thermometer should be packed in the same manner. 217. Precautions to be taken in the use of hydrometers and thermometers. - Glass hydrometer stems should be lifted from the wooden box by the large bulb and not by the narrow stem. If the bulb is at all tightly jammed in the box and the stem is used to try to raise it, there is such risk of breakage.\nII. Glass hydrometers -  Each stem should be packed in a separate cylindrical tin case whose diameter is aboue 2.54 cm greater than the width of the hydrometer bulb; and at least 2.54 cm longer than the hydrometer stem-\nGlass hydrometers\n(a) the tin case should first have some cotton wool placed in it to a depth of 2.54 cm.\n(b) the hydrometer should then be gently placed in the case, bulb uppermost (not pushed down through the cotton wool to the foot of the case);\n(c) it should then be thoroughly packed round with dry sawdust, not rammed too rightly, allowing equal distance all round between the bulb and case;\n(d) the case should then be filled with sawdust to within 1.27 cm of the top. The remaining 1.27 cm should be filled with cotton wool;\n(e) the cap should then be put on without undue force and securely fastened. A loose cap should not be used.\nIII. The tin case should then be packed in a wooden box large enough to allow each case having a good layer of sawdust to separate it -\n(a) from neighboring tins; and\n(b) from the sides and ends of the box.\nIV. The thermometer should be packed in the same manner.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 256
    },
    "prev_section": "215",
    "next_section": "217"
}