    "act_title": "Tamil Nadu Combined Development and Building Rules, 2019",
    "act_slug": "tamil-nadu-combined-development-and-building-rules-2019",
    "section_label": "Section",
    "section": {
        "number": "37",
        "title": "37. Planning Parameters of Institutional Buildings.",
        "chapter": null,
        "content": "Sl. No.\nSl. No.\nDescription\nDescription\nContinuous Building Areas\nContinuous Building Areas\nOther areas\nOther areas\n1\n2\n3\n4\nA.\nMinimum road width\n7.20m\nMinimum 7.2m for schools up to\n\t\t\t\thigher secondary level and industrial training institutes.\nFor others, min. 9 m\nB.\nMaximum Height\n18.30m.\nC.\nNormally Permissible FSI\n2.0\nD.\nMinimum Setbacks\nWhere Street Alignment/new road is prescribed,\n\t\t\t\tit shall be from that street alignment/narrow line. In the case\n\t\t\t\tof others, it shall be from the property boundary.\n(i)\nFront Setback\n6m\n6m\n(ii)\nSide Setback\nNil\n6m\nFor schools - 2m\n(iii)\nRear Setback\nNil\n6m\nFor schools - 2m\nE.\n(a) Structures\n\t\t\t\tpermissible in the minimum prescribed Front set back, Side\n\t\t\t\tsetback and Rear set back are given in the rule 28\n(b) In addition, Gate pillars, gopurams, and\n\t\t\t\tincidental structures (with height not exceeding 4m) such as\n\t\t\t\tservant room, cloak room, and watch man booth, cycle stand,\n\t\t\t\tKitchen and toilets are permissible in these minimum prescribed\n\t\t\t\tsetback spaces.\nF.\nParking spaces shall be provided within the site\n\t\t\t\tconforming to standards prescribed in the Annexure - IV.\nG.\nRainwater harvesting provisions as prescribed in\n\t\t\t\tthe Annexure - XXII.\nH.\nThe minimum width of corridor shall be as given\n\t\t\t\tin rule 42\nI.\nSpecial regulations for physically disabled\n\t\t\t\tstated in the rule 43 shall be adhered to.\nJ.\nThe applicant not being a government department or agency\n\t\t\t\tshall deposit a sum at the rate of 50% of the infrastructure and\n\t\t\t\tamenity charges as a refundable non-interest earning security and\n\t\t\t\tearnest deposit. The deposit shall be refunded on completion of\n\t\t\t\tdevelopment as per the approved plan as certified by Competent\n\t\t\t\tAuthority; if not, it would be forfeited.\nK.\nThe reservation of Land for Community recreational purpose\n\t\t\t\tsuch as park or play ground required in these regulations shall\n\t\t\t\tbe as given in the rule 41.\nNote. - (i) In Continuous Building Area (CBA), there shall be at-least 1m wide internal passage from rear to front in ground level or ground floor, directly accessible to road.\nNote.\n(ii) In the case of schools, the development shall confirm to the additional safety standards stated in the Annexure - XV.\n(iii) The maximum height of the building shall not exceed 18.30 meters provided water tanks, chimneys, Architectural features such as flag masts, gopurams, minarets, steeples and other ornamental structures which are not intended for human habitation may be permitted subject to a ceiling of 30.5 meters from ground level.\n(iv) In cases of Hospital Buildings with Ground Floor/Stilt Floor + First Floor and above and floor area exceeding 300 sq.m. in each floor, the special provisions for Hospital Buildings prescribed in Annexure - IX shall be adhered to.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 37
    },
    "prev_section": "36",
    "next_section": "38"
}