{
    "act_title": "Revised Building Rules, 2007",
    "act_slug": "revised-building-rules-2007",
    "section_label": "Section",
    "section": {
        "number": "6",
        "title": "6. Requirements of Approach Road for Building Sites/ Plots:",
        "chapter": null,
        "content": "TABLE II\nTABLE II\nType/ Use of\n\t\t\t\t\tBuilding plot permissible\nMinimum abutting road width required (in\n\t\t\t\t\tmeters)\n(A) Sites In Old/existing Built-Up\n\t\t\t\t\tAreas/congested Areas/settlement (Gram Khantam/abadi) (As Listed\n\t\t\t\t\tIn Annexure I, IV, V and VI Respectively)\n(A) Sites In Old/existing Built-Up\n\t\t\t\t\tAreas/congested Areas/settlement (Gram Khantam/abadi) (As Listed\n\t\t\t\t\tIn Annexure I, IV, V and VI Respectively)\n* Residential Buildings - maximum permissible upto 10m height\n6\n* Non-residential buildings and mixed occupancies -maximum\n\t\t\t\t\tpermissible up to 12 m height\n(B) Sites In New Areas/ Approved Layout\n\t\t\t\t\tAreas\n(B) Sites In New Areas/ Approved Layout\n\t\t\t\t\tAreas\nThe Type of Buildings & Intensity of\n\t\t\t\t\tDevelopment Shall Be W.R.T. The Abutting Road Width, Viz.,\nB 1 Non-High Rise Residential Buildings\n\t\t\t\t\tincluding Apartment Complexes; Buildings with shopping on GF and\n\t\t\t\t\tresidences on upper floor; Basic level social amenities like\n\t\t\t\t\tNursery School / Primary School/ Religious Place / Public Health\n\t\t\t\t\tCenter / Dispensary / Diagnostic Laboratory/ Police outpost/Post\n\t\t\t\t\tOffice/ Neighbourhood Library cum Community Center and all\n\t\t\t\t\tbuildings up to 15 m height\n9\nB 2 In addition to B 1 above, High Rise\n\t\t\t\t\tBuilding/ Complex of height above 18 m and up to 24 m; Group\n\t\t\t\t\tHousing Scheme; Primary School, Middle school / Tutorial\n\t\t\t\t\tinstitution / General Industry / Godown / Petrol/diesel Filling\n\t\t\t\t\tstation; High School, Junior College/ General Degree and other\n\t\t\t\t\tnonprofessional College / Commercial Complex, 12  Computer\n\t\t\t\t\tunits/ Office Building, ITES Complex, Nursing Home / Community\n\t\t\t\t\tHall / Function/Marriage Hall / Assembly Hall/Cinema Theater;\n\t\t\t\t\tService establishment/ Workshop; Others not specified in the\n\t\t\t\t\tTable and all non high-rise buildings up to 18 m height\nB 3 In addition to B 1 & B 2 above, High\n\t\t\t\t\tRise buildings above 24 m and up to 30 m height; General Degree\n\t\t\t\t\tand other non-professional College / Polytechnic, ITI;\n\t\t\t\t\tProfessional College Campus; Multiplex Complexes, Shopping\n\t\t\t\t\tMalls, Hospitals and all non high-rise buildings up to 18 m\n\t\t\t\t\theight\n18\nB 4 In addition to B 1 to B 3 above, High Rise\n\t\t\t\t\tBuildings above 24 m height and up to 45 m height\n24\nB 5 In addition to B 1 to B 4 above, High Rise\n\t\t\t\t\tBuildings above 45 m height\n30\n* Provided that in case of single plot sub-division approved by the sanctioning authority, a means of access of minimum 3.6 m pathway may be considered for individual residential building and 6m for Apartment Complexes / Commercial Complexes and other non-high rise buildings.\n(i) In case of (A) above, where the existing road is less than 6 m, building in the site would be allowed after setting back the building 4.5 m from the center line of such existing road and after leaving the front setback.\n(ii) In case of existing buildings approved prior to these Rules, further additions of floors on the earlier permitted building may be considered either as per these rules or the then rules in force in respect of setbacks, whichever is the applicant opts for. This will not apply for building extensions or redevelopment ventures in such sites.\n(iii) Building line is from the edge of the Road Right-of-way (whether existing or proposed). In individual plots where a plot abuts two or more roads, the setbacks along these abutting roads shall be as per the respective building line of the roads.\n(iv) In case of existing areas not covered in Annexures and sites not covered in road widening, building approvals in interstitial sites may be considered by the sanctioning authority with reasons to be recorded in writing and with the following height restriction:\n(v) All buildings shall be constructed in conformity with the zoning regulations.\n7.0 Permissible Height & Setback Requirements.\n(i) The height of buildings permissible in a given site/plot shall be subject to restrictions given in the Annexures.\n(ii) There are no specific Floor Area Ratio and plot coverage stipulations. The permissible coverage would be as per the minimum setbacks to be left within the given site. The minimum setbacks and permissible height would be as per Table III below.\nTable - III\nTable - III\nPermissible Height & Setbacks for Non-High Rise Buildings\nPermissible Height & Setbacks for Non-High Rise Buildings\nSl No\nPlot Size (in Sq.mts.)\nParking provision\nHeight permissible (in mts.)\nBuilding line or minimum front setback (in mt.)\n\t\t\t\tto be left\nUp to 12m\nAbove 12m & up to 18m\nAbove 18m & up to 24m\nAbove 24m & up to 30m\nAbove 30m\nMinimum setback / setbacks on remaining sides (in\n\t\t\t\tmts.)\n1\n2\n3\n4\n5\n6\n7\n8\n9\n10\n1\nLess than 100\n-\n7\n1.5\n4\n5\n6\n7.5\n-\n2\n100 & upon 200\n-\n10\n2\n4\n5\n6\n7.5\n1.0\n3\nAbove 200 & upto 300\nStilt parking floor allowed\nUpto 7\n2\n4\n5\n8\n7.5\n1.0\nUpto 10\n3\n4\n5\n6\n7.5\n1.5\n4\nAbove 300 & Upto 400\nStilt parking floor allowed\nUpto 7\n3\n4\n5\n6\n7.5\n1.5\nUpto 12\n3\n4\n5\n6\n7.5\n1.5\n5\nAbove 400 & upto 500\nStilt parking floor allowed\nUpto 7\n3\n4\n5\n6\n7.5\n2.0\nUpto 12\n3\n4\n5\n6\n7.5\n2.5\n6\nAbove 500 & upto 750\nStilt parking floor allowed\nUpto 7\n3\n4\n5\n6\n7.5\n2.5\nUpto 12\n3\n4\n5\n6\n7.5\n3.0\nBelow 15\n3\n4\n5\n6\n7.5\n3.5\n7\nAbove 750 & upto 1000\nStilt parking + One cellar floor allowed\nUpto 7\n3\n4\n5\n6\n7.5\n3.0\nUpto 12\n3\n4\n5\n6\n7.5\n3.5\nBelow 15\n3\n4\n5\n6\n7.5\n3.5\n8\nAbove 1000 & upto  1500\nStilt Parking + 2 Cellar floors allowed\nUpto 7\n3\n4\n5\n6\n7.5\n3.5\nUpto 12\n3\n4\n5\n6\n7.5\n4\nBelow 15\n3\n4\n5\n6\n7.5\n5\nBelow 18\n3\n4\n5\n6\n7.5\n6\n9\nAbove 1500 &  upto 2500\nStilt parking + 2  Cellar floors allowed\nUpto 7\n3\n4\n5\n6\n7.5\n4.0\nBelow 15\n3\n4\n5\n6\n7.5\n5.0\nBelow 18\n3\n4\n5\n6\n7.5\n6.0\n10\nAbove  2500\nStilt parking + 2 or more Cellar  floors allowed\nUpto 7\n3\n4\n5\n6\n7.5\n5.0\nBelow 15\n3\n4\n5\n6\n7.5\n6.0\nBelow 18\n3\n4\n5\n6\n7.5\n7.0\n(i) (a) Buildings of height above 15mts. and below 18m height (inclusive of parking floors) in Sl.Nos.8, 9 and 10 of above Table, shall be permitted only in such plots which abut roads of 12mt. minimum (40ft) width. Necessary prior clearance from Fire Department shall be necessary for such buildings which have 6 floors .\n(b) Stilt parking floor permissible is exclusive of height of building upto 15mts. height of stilt floor shall not exceed 2.75 mt. In case of non-residential occupancies on sites below 750 sq m, for parking a semi-basement of 3 m height and with such height not exceeding 1.5 m above ground level may be considered. In case of parking floors where mechanical system and lift are provided, height of such parking floor upto 4.0mt. could be considered.\n(c) Wherever cellars/sub-basements are permissible, these are excluded from height of building.\n(d) No Balcony projections shall be allowed to extend on to the minimum setbacks. These if provided, shall be within minimum setback required to be left. However, a portico without access to the top may be considered in the front open space.\n(e) In case of Sl. Nos. 4 to 10 of above Table, stepped type buildings or incremental type buildings may be allowed only in respect of individual residential or educational / institutional buildings and such incremental development would be considered only after a minimum time period of 5 years.\n(f) As per the provisions of the Andhra Pradesh Fire Service Act, 1999, Commercial buildings of height 15mts. and above, and buildings of public congregation like schools, Cinema theatres, function halls and other assembly buildings on plot area of 500 sq.mts. and above or of height above 6mts. are required to obtain prior clearance from Fire Department from fire safety point of view.\n(ii) for the purpose of these Rules, the following conversion from Meters-Kilograms-Second (M.K.S) and Feet-Pound-Second (F.P.S) system shall be reckoned:\n(i) 3m - 10ft         (ii) 6m = 20ft\n(iii) 7.5m=25ft       (iv) 9m= 30ft\n(v) 12m = 40ft       (vi) 15m=50ft\n(vii) 18m=60ft       (viii) 24m=80ft\n(ix) 30m=100ft        (x) 45m=150ft\n(xi) 60=200ft.\n(iii) The setbacks are to be provided after leaving the affected area of the plot/site, if any, for road widening. In respect of owners who surrender land affected in road widening free of cost under would be eligible for concessions in setbacks under GOMs.No.33 MA, dated 03.02.2001.\n(iv) Building line is from the edge of the Road Right-of-way (whether existing or proposed).\n(v) Where the lighting and ventilation of a building is through the means of a chowk or inner courtyard or interior open space/duct, such open space shall be open to sky and of area at least 9.0 sq m and no side shall be less than 1.5m in case of buildings of height upto 12m and in case of buildings of height above 12m no side shall be less than 2 m.\n(vi) A strip of at least 1.0 m greenery/lawn along the frontage of the site within the front setback shall be compulsorily developed and maintained with greenery and trees.\n(vii) for plots above 200 sq.m in addition to (vi) above, a minimum 1 m wide continuous green planting strip in the periphery on remaining sides are required to be developed and maintained as greenery and trees within the setback.\n(viii) for all residential/institutional/industrial plots above 750 sq m, in addition to (vi) and (vii) above, 5 % of the site area has to be developed as tot-lot/landscaped area and trees planted and maintained. Such organized open space could be in more than one location, shall be open to sky and shall be of a minimum width of 3.0mts.\n(ix) To enhance the streetscape in respect of 18 m and above roads, no front compound wall is recommended along the front setback. Only iron grill or low height green hedge and / or with sloping type planters is recommended along such roads.\n(x) In all plots 750 sq m and above, provision shall be made for earmarking an area of 6 sq m for the purpose of siting of public utilities like distribution transformer, etc. within the owner's site and located in a corner splay of setback, subject to mandated public safety requirements, ensuring turning radius for vehicles etc.\n(xi) If the above greenery mentioned at (iv) to (viii) above and Rule 9.9 is not maintained and rain water harvesting structures are not provided, 10% of additional Property tax every year would be imposed as penalty by the sanctioning authority till the said condition is fulfilled.\n(xii) In case of plots 300 sq m and upto 750 sq. mt, it is permitted to transfer up to one metre of setback from one side to any other side, and in case of plots above 750 sq m, it is permitted to transfer up to 2 m of setback, which needs to be uniform at any given point, subject to maintaining of minimum building line in the front.\n(xiii) In case of corner plots or plots abutting two or more roads, the front setback shall be as per the building line for the respective abutting road width.\n(xiv) for narrow plots, where the length is 4 times the width of the plot, the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of 1m on each side.\n(xv) The space between 2 blocks shall be as given Table-V.\n(xvi) The height of the building will be calculated after excluding the parking floors for the purpose of computation of minimum setbacks to be left.\n(xvii) Where all the owners of sites along an abutting road come forward for widening of the road by undertaking preparation of a Road Development Plan which would improve circulation in the area and duly approved by the competent authority, and by leaving the area affected in the widening of such road free of cost and implement it within one year, then higher height of the corresponding widened road width would be considered for such sites,\n(xviii) In case of plots upto 200 sq m, semi-detached houses with common wall and height upto 10 m would be permissible with building line as given in above Table and 1 metre setback on remaining sides\n(xix) Splay at road junctions, including Y-junctions shall be provided as follows:\n(i) The building requirements and standards other than heights and setbacks specified in the National Building Code of India, 2005 shall be complied with.\n(ii) Such buildings shall be undertaken by owners by engaging registered architects/ licenced builders/developers and licenced structural engineers. The designs and building plans shall be countersigned by the owner, licenced developer, registered architect, licenced engineer and a qualified & licenced structural Engineer who shall be responsible for the supervision, structural safety, earthquake safety, fire safety and specifications compliance of such buildings. Buildings shall be designed for compliance with earth quake resistance and resisting other natural hazards. The Completion Certificate shall mention that the norms have been followed in the design and construction of buildings for making the buildings resistant to earthquake and natural hazards, compliance with structural safety and fire safety requirements.\n(iii) The work of the building services like sanitation, plumbing, fire and life safety requirements, lifts, electrical installations, and other utility services shall be executed under the planning, design and supervision of qualified and competent technical personnel.\n(iv) The parking requirements shall comply as given in these rules. The parking facilities and vehicles driveways etc. shall be maintained to the satisfaction of the sanctioning Authority.\n(v) The applicant / builder / developer may provide for solar water heating system in the building and solar lighting in the site for outdoor lighting within the site, etc. and give a bank guarantee to this effect to the sanctioning authority for compliance of the same.\n(vi) All Public and semi-public buildings / Assembly buildings / Commercial complexes and such other public congregation buildings with covered area above 300 sq m shall be designed and constructed to provide facilities to the physically handicapped persons as prescribed in the National Building Code of India,2005.\n(vii) In all buildings irrespective of above height provisions, the requirements of parts of the building like size and area requirements of habitable rooms, kitchen, bathrooms and Water closets, other areas, corridor and staircase widths, service ducts, etc. shall conform to the National Building Code of India,2005.\n(viii) All environmental aspects like provision of Rain water harvesting structures, greenery, solar heating and lighting systems, AP WALTA Act provisions, etc shall be complied in such of the sites and Schemes where these are applicable.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 4
    },
    "prev_section": "5",
    "next_section": "8"
}