    "act_title": "Rajasthan Factories Rules, 1951",
    "act_slug": "rajasthan-factories-rules-1951",
    "section_label": "Section",
    "section": {
        "number": "65A",
        "title": "65A. Protection of workers attending to prime movers.",
        "chapter": null,
        "content": "[65AA. Ovens and Dryers:\nApplication.\nDefinition.\nSeparate electrical connection.\nDesign, Construction, examination and testing.\n(b) No oven or drier shall be taken into use in a factory for the first time unless a competent person has thoroughly examined all its parts and carried out the tests as are required to establish that the necessary safe systems and controls provided for safety in operation for the processes for which it is to be used and a certificate of such examination and tests signed by that competent person has been obtained and is kept available for inspection.\n(c) All parts of an oven or drier which has undergone any alteration or repair which has the effect of modifying any of the design characteristics, shall not be used unless a thorough examination and test as have been mentioned in clause (b) has been carried out by a competent person and a certificate of such examination and tests signed by that competent person has been obtained and is kept available for inspection.\nSafety Ventilation.\n(i) shows continuously the concentration of the flammable substances in air present in the oven or drier at any instant;\n(ii) sounds an alarm when the concentration of the flammable substance in air in any part of the oven or drier reaches a level of 50 percent of its lower explosive limit: and\n(iii) shuts down the heating system of the oven or drier automatically when the concentration in air of the flammable substance in any part of the oven or drier reaches a level of 60 percent of its lower explosive limit, is provided to the oven or drier and maintained in efficient working condition.\nExplosion Panels.\nInterlocking arrangements.\n(1) all ventilating fans and circulating fans whose failures would adversely effect the ventilation rate of flow pattern, are in operation before any mechanical conveyor that may be provided for feeding the articles or substances to be processed in the oven or drier is put into operation:\n(ii) failure of any of the ventilating or circulating fans will automatically stop any conveyor as referred to in clause (i) as may be provided, as well as stop the fuel supply by closing the shut off valve and shut off the ignition in the case of gas or oil fired ovens, and in the case of electrically heated ovens switch off the electrical supply to the heaters;\n(iii) the 'above said mechanical conveyor is set in operation before the above said shut off valve can be energized: and\n(iv) the failure of the above said conveyor will automatically close the above said shut off valve in the case of ovens and dryers heated by gas, oil or steam and deactivate the ignition system, or cut off the electrical heaters in the case of electrically heated ovens or furnaces:\nAutomatic preventilation.\nTemperature Control.\nMultistage Processes.\nCombustible substances not to drip on electrical heaters or burners flame.\n(b) A register shall be maintained in which the details of the various tests carried out from time to time under clause (a) shall be entered and every entry made shall be signed by the person making the tests.\nTraining of Operators.\nPolymerising Machines.\n(b) Infrared ray heaters of polymerising machines shall be cut off while running the prints.\"]",
        "footnote": "",
        "is_definition": false,
        "sort_order": 147
    },
    "prev_section": "65",
    "next_section": "65B"
}