    "act_title": "Punjab Urban Planning and Development Building Rules, 2018",
    "act_slug": "punjab-urban-planning-and-development-building-rules-2018",
    "section_label": "Section",
    "section": {
        "number": "47",
        "title": "47. Risk Based Classification of building proposals.",
        "chapter": null,
        "content": "(ii) storage and handling of hazardous and highly flammable liquids, liquefiable gases like LPG, rocket propellants, etc;\n(iii) storage and handling of hazardous and highly flammable or explosive materials (other than liquids); and\n(iv) manufacture of artificial flowers, synthetic leather, ammunition, explosives and fireworks.\nNote. - A list of hazardous substances giving quantities, for which or exceeding which owners handling such substances are required to be covered under the Public Liability Insurance Act, 1991, has been notified under the Rules on Emergency Planning, Preparedness and Response for Chemical Accidents by the Government of India, Ministry of Environment and Forests, Notification No. G.S.R. 347(E), dated the 01st August 1996.\nNote.\n(1) Classification of risk based storage building.\nTable 55 - Classification of risk based\n\t\t\t\tstorage building\nTable 55 - Classification of risk based\n\t\t\t\tstorage building\nCategory\nCategory\nStorage Material Specifications\nStorage Material Specifications\nStacking\nStacking\nDesignated officer for site Inspection\nDesignated officer for site Inspection\nHeight (in m)\nHeight (in m)\nMedium\nMedium\nHigh\nHigh\nCategory-I(Low Risk)\nCategory-I(Low Risk)\nArticles such as Carpets,\n\t\t\t\tNon-synthetic/synthetic yarn and fabrics. Mechanical and\n\t\t\t\telectrical goods (dominantly metal parts), Glassware and\n\t\t\t\tcrockery, fiberboards, groceries, metal goods, Papers other than\n\t\t\t\tthose listed under categories Moderate and High, Powdered and\n\t\t\t\tcanned foods, Plastic/glass bottles containing nonflammable\n\t\t\t\tliquids, etc.\n4\n6.5\nAssistant Town Planner/Assistant Engineer/\n\t\t\t\tSenior Divisional Engineer\nCategory-II(Medium Risk)\nCategory-II(Medium Risk)\nArticles such as Batteries, Baled\n\t\t\t\tcotton/synthetic fibers, Books, Baled cork, Baled waste paper,\n\t\t\t\tCartons containing alcohols ( in cans/bottles), Cartons of canned\n\t\t\t\tlacquers which dry by solvent evaporation, Chipboard, Cardboard\n\t\t\t\trolls (horizontally Stored), Cereals/Grains/Foodstuff/ Flour/\n\t\t\t\tSugar in sacks, Cellulose/Cellulose pulp, Electrical goods other\n\t\t\t\tthan those stated in Category low, Flammable liquids in\n\t\t\t\tnon-combustible containers, Leather goods, Palletized liquor\n\t\t\t\tstocks, Plastics (non-foamed, other than cellulose nitrate),\n\t\t\t\tRolled pulp and paper and asphalted paper (Horizontal storage),\n\t\t\t\tVeneer sheets, Wooden patterns, Metal/wooden furniture with\n\t\t\t\tplastic seats, etc.\n3\n5.5\nDistrict Town Planner/Executive Engineer\nCategory-III(High Risk)\nCategory-III(High Risk)\nArticles such as Bitumen/Wax coated paper,\n\t\t\t\tCandles, Carbon black, Card board rolls (vertically stored),\n\t\t\t\tCharcoal, Coal, cellulose nitrate, Foamed plastic and foam rubber\n\t\t\t\tproducts, Flammable liquids in combustible containers, Linoleum\n\t\t\t\tproducts, Matches, Plastics other than those stated in Category\n\t\t\t\tModerate, Rolled pulp and paper and asphalted paper (vertical\n\t\t\t\tstorage), Rubber goods including tyres and tubes, Sawn timber,\n\t\t\t\tVentilated wood stacks, Waxed and asphalt coated papers and\n\t\t\t\tcontainers in cartons, Wood wool, wooden pallets and flats\n\t\t\t\t(idle), Ail materials having wrappings or preformed containers of\n\t\t\t\tfoamed plastics, etc.\n2\n4.5\nSenior Town Planner/Senior Engineer.\nCategory-IV (Extreme High Risk)\nCategory-IV (Extreme High Risk)\nOff cuts and random pieces of foamed plastic or\n\t\t\t\trubber rolls of sheets of foamed plastic or foamed rubber, Foam\n\t\t\t\tmattress, Expanded polystyrene packaging, Foam upholstery, etc.\n1.25\n3.5\nSenior Town Planner/Senior Engineer.\nNotes. - (a) The deflector of the sprinkler fitted in the ceiling shall be at more than 1.5 m from the goods stored below. However, in case of jute storage, no jute stock shall reach within 2 m of the deflectors of the sprinkler heads.\nNotes.\n(b) In case of storage in racks or shelves, if the height of storage is more than what is specified, intermediate sprinklers shall be provided for each shelf/rack in addition to the ceiling sprinklers and overall design density and Assumed Maximum Area of Operation shall be maintained as per Table 5 of IS: 15105.\n(c) The aisle width between the storage stacks shall not be less than 2.5 m and the maximum area of each storage stack shall not be more than 150m2. If these parameters are exceeded, the design density applicable shall be loaded by 2.5 L/min/m2.\n(d) In case of mixed storage (both moderate and high hazard storage) in buildings, the parameters will be governed by the most hazardous occupancy.\n(e) Goods stored not higher than what is stated above table for the appropriate category or not higher than the eaves height of the roofs or within 1 m of a flat ceiling whichever is the lowest shall be regarded as moderate hazard storage. If the above conditions are not met, the risk shall be regarded as high hazard storage.\n(f) Any new use which increases the number of occupants to a figure comparable with other classes of occupancy shall change the classification of the building to that of the new use (for example, Warehouse used for office purposes).\n(g) Warehouse buildings shall not include any article which is highly combustible or explosive materials or products which are liable to bum with extreme rapidity and or which may produce poisonous fumes or explosions for storage, handling and which involve highly corrosive, toxic or noxious alkalis, acids or other liquids or chemicals producing flame, fumes and explosive, poisonous, irritant or corrosive gases; and for the storage, handling of any material producing ex-plosive mixtures of dust which result in the division of matter in to fine particles subject to spontaneous ignition as such buildings fall in Hazardous Building Category.\n(2) Classification of risk based industrial building.\nTable 56 Classification of risk based\n\t\t\t\tindustrial building\nTable 56 Classification of risk based\n\t\t\t\tindustrial building\nCategory\nCategory\nNature of risk\nNature of risk\nDesignated officer for site Inspection\nDesignated officer for site Inspection\nLow risk\nLow risk\nThis subdivision shall include any building in\n\t\t\t\tTown which the contents are of such comparative low\n\t\t\t\tcombustibility and the industrial processes or operations\n\t\t\t\tconducted therein are of such a nature that there is hardly any\n\t\t\t\tpossibility for any self-propagating fire to occur and the only\n\t\t\t\tconsequent danger to life and property may arise from panic,\n\t\t\t\tfumes or smoke, or fire from some external source.\nAssistant Planner/Assistant Engineer/Senior Divisional Engineer\nMedium risk\nMedium risk\nThis subdivision shall include any building in\n\t\t\t\twhich the contents or industrial processes or operations\n\t\t\t\tconducted therein are liable to give rise to a fire which will\n\t\t\t\tburn with moderate rapidity or result in other hazardous\n\t\t\t\tsituation and may give off a considerable volume of smoke, but\n\t\t\t\tfrom which neither toxic fumes nor explosions are to be feared in\n\t\t\t\tthe event of fire.\nDistrict Town Planner/Executive Engineer.\nHigh risk\nHigh risk\nThis subdivision shall include any building in\n\t\t\t\twhich the contents or industrial processes or operations\n\t\t\t\tconducted therein are liable to give rise to a fire which will\n\t\t\t\tburn with extreme rapidity or result in other hazardous situation\n\t\t\t\tor from which poisonous fumes or explosions are to be feared in\n\t\t\t\tthe event of a fire.\nSenior Town Planner/ Senior Engineer.\n(a) For determination of fire loads and fire load density for arriving at the classification of occupancy hazard, guidance on calorific values of some common materials is given at Annexure A of part IV of the National Building Code of India, 2016.\n(b) A broad classification of industrial occupancies into low, moderate and high hazard classes is given at Annexure B of part IV of the National Building Code of India, 2016.\n(3) Classification of risk based on nature of occupancy in building.\nTable 57\n\t\t\t\tClassification of risk based on nature of occupancy in building\nTable 57\n\t\t\t\tClassification of risk based on nature of occupancy in building\nCategory\nCategory\nNature of occupancy\nNature of occupancy\nDesignated officer for site Inspection\nDesignated officer for site Inspection\nLow risk\nLow risk\n• Residential\n\t\t\t\t(excluding rental housing) and commercial like shops, booths,\n\t\t\t\tsco's building and office below 15m height,\n• Creche and Pre Nursery/ Nursery School\nAssistant Town Planner/Assistant Engineer/ Senior Divisional\n\t\t\t\tEngineer\nMedium risk\nMedium risk\n• Residential and\n\t\t\t\tcommercial like shops, booths, sco's building and office 15m and\n\t\t\t\tabove but below 30m\n• Educational\n\t\t\t\tbuilding, Nursing Homes, Clinics, laboratory, below 15m\n• Orphanage Home ,\n\t\t\t\tOld Age Home, Children's Centre / Care Centre / School /\n\t\t\t\tInstitute for Mentally challenged or Physically Handicapped\n\t\t\t\tPerson below 15m\n• Hotel/ Motels,\n\t\t\t\tGuest House, Lodging & Boarding / Service Apartments below\n\t\t\t\t15m\n• Restaurant/ Dabha\n\t\t\t\tseating capacity below 50 persons\n• recreational,\n\t\t\t\tsports complex (low rise)\n• rental housing below 15m\nDistrict Town Planner/Executive Engineer.\nHigh risk\nHigh risk\n• Assembly building\n\t\t\t\tlike Religious, cinemas, multiplex, miniplex, concert hall,\n\t\t\t\texhibition hall, convention centre, marriage palace, stadium,\n\t\t\t\tcommunity centre, club, Religious Building, Auditorium, Museum,\n\t\t\t\tGymnasium etc.\n• Residential and\n\t\t\t\tcommercial like shops, booths, sco's building and office 30m and\n\t\t\t\tabove\n• Educational\n\t\t\t\tbuilding, Nursing Homes, Clinics, laboratory, 15m and above\n• Orphanage Home ,\n\t\t\t\tOld Age Home, Children's Centre / Care Centre / School /\n\t\t\t\tInstitute for Mentally challenged or Physically Handicapped\n\t\t\t\tPerson 15m and above\n• Commercials such\n\t\t\t\tas Shopping Mall / Shopping Complex\n• Restaurant/ Dabha\n\t\t\t\tseating capacity 50 persons and above\n• Hospital\n• Wholesale Trade/\n\t\t\t\tWare House/ Integrated Freight complex (Standalone)\n• rental housing 15m and above\nSenior Town Planner/ Senior Engineer.\nNote. - Inspection of the risk based buildings site at the time of approval of building plan shall be carried out as mentioned in Table 58 and Table 59 below.\nNote.\nTable 58: where the date of\n\t\t\t\tissuance of change of land use is within three months from the\n\t\t\t\tdate of application for approval of building plans\nTable 58: where the date of\n\t\t\t\tissuance of change of land use is within three months from the\n\t\t\t\tdate of application for approval of building plans\nS. No.\nS. No.\nNature of risk\nNature of risk\nInspection of site\nInspection of site\nRemarks\nRemarks\nI.\nLow risk\nNot applicable\nSince the\n\t\t\t\tsite has already been inspected at the time of approval of Change\n\t\t\t\tof Land Use and the application for approval of building plans\n\t\t\t\thas been submitted with in the period of three months. Hence\n\t\t\t\tre-inspection of the site may not be required after such a short\n\t\t\t\tperiod of time.\nII.\nMedium risk\nIII.\nHigh risk\nTable 59: where the date of issuance of change of land use\n\t\t\t\texceed a period of three months\nTable 59: where the date of issuance of change of land use\n\t\t\t\texceed a period of three months\nS. No.\nS. No.\nNature of risk\nNature of risk\n% of random inspection\n% of random inspection\nRemarks\nRemarks\nI.\nLow risk\n25\n-\nII.\nMedium risk\n50\nIII.\nHigh risk\n100\nPART XIII\nRegistration of Plumbers",
        "footnote": "",
        "is_definition": false,
        "sort_order": 42
    },
    "prev_section": "46",
    "next_section": "48"
}