{
    "act_title": "Merchant Shipping (Seafarer Accommodation) Rules, 2016",
    "act_slug": "merchant-shipping-seafarer-accommodation-rules-2016",
    "section_label": "Section",
    "section": {
        "number": "12",
        "title": "12. Galleys, Provision rooms, cold storage, refrigerating equipment.",
        "chapter": null,
        "content": "(b) The galley shall be situated as near as may be to the mess rooms provided for the seafarer and any necessary equipment shall be provided to enable food to be served in the mess rooms under all weather conditions.\n(c) There shall be no direct opening between the galley and any sleeping room.\n(d) Every galley shall be provided with exhaust fans which will draw off fumes from the cooking appliances therein and discharge the fumes into the open air.\n(e) The floor of the galley shall be provided with gutters and with scuppers which shall be led overboard or to an enclosed tank served by mechanically operated suction pump. The position and number of the gutter and scuppers shall be such as will ensure the efficient drainage of the floor.\n(f) The cooking appliances in the galley shall be arranged in a manner which shall facilitate the cleaning of the galley.\n(g) All cupboards and dressers in the galley shall be made of material which is impervious to dirt and moisture and can easily be kept clean. All metal parts of the cupboards and dressers shall be rustproof. The bottoms of all cupboards and dressers in the galley shall either be flush with the deck or shall be so fitted as to enable the deck space beneath them to be readily accessible for cleaning.\n(h) Every galley shall be provided with such equipment as will enable food in sufficient quantity to be properly and readily prepared for the persons whom the galley is intended to serve, and the cooking utensils to be hygienically cleaned.\n(i) Every galley shall be provided with one or more cooking appliances with an oven or cooking range of adequate capacity.\n(b) Every dry provision store room shall be enclosed by bulkheads constructed of steel or other suitable material.\n(c) Access to every dry provision store room shall be obtained from a passageway, galley, pantry or another store room, or from a position on an open deck with, in so far as is reasonable and practicable in the circumstances, shall be a protected position.\n(d) Every dry provision store room shall be so situated, constructed and ventilated as to avoid deterioration of the stores through heat, draught, condensation or infestation by insects or vermin.\n(b) Access to every cold store room shall be obtained from a passageway, galley or pantry or from another store room.\nSecond Schedule\n[ See rule 2(1) (k)]\nTrunked Mechanical Ventilation System\nCategory\nSpace\nFresh air changes per hour\nVolume of fresh air for each person likely to use\n the room at any one time (m 3 /min)\n(1)\n(2)\n(3)\n(4)\nA\nSpaces other than those in category\n (C) in deck houses above the upper or shelter deck :-\n(1) outside rooms (other than rooms\n adjoining machinery casing)\n(2) inside rooms and rooms adjoining machinery casing\n10\n15\n1.42\n1.42\nB\nSpaces other than those in category\n (C) in side-to-side superstructures above the upper or shelter\n deck:\n(1) outside rooms (other than rooms\n adjoining machinery casing\n(2) inside rooms and rooms adjoining machinery casing\n12\n15\n1.42\n1.42\nC\nMess rooms, smoking rooms and\n recreation rooms (in each case above the upper or shelter decks):\n(1) not adjoining machinery casing\n(2) adjoining machinery casing\n15\n18\n0.71*\n0.71*\nD\nPassageways adjoining machinery casings\n4\nE\nRooms in between decks (including\n shelter between decks) of ships propelled by internal combustion\n machinery\n(1) Rooms clear of machinery casing\n(2) Rooms abreast of but not\n adjoining machinery casing\n(3) Rooms adjoining machinery casing (other than mess rooms,\n smoking rooms and recreation rooms)\n12\n12\n15\n1.42\n1.42\n1.7\n(4) Mess rooms, smoking rooms, and recreation rooms (in each\n case adjoining machinery casing)\n18\n0.71\nF\nRooms in tween decks\n (including shelter tween decks) of steamships :-\n(1) Rooms clear of machinery casing\n(2) Rooms abreast of, but not\n adjoining machinery casing.\n(3) Rooms immediately above\n machinery casing or abreast of and adjoining machinery casing\n (other than mess rooms, smoking rooms and recreation rooms)\n(4) Mess room, smoking rooms and recreation rooms (in each\n case adjoining machinery casing)\n12\n15\n18\n20\n1.42\n1.7\n1.7\n0.85**\nTable II\nCategory\nSpace\nFresh air change per hour\nSupply\nExhaust\n(1)\n(2)\n(3)\n(4)\nG\nGalleys\n20 (a)(b)\n40(b)\nH\nSanitary accommodation, drying rooms and pantries\n10\n20\nJ\nWards in permanent hospitals\n12 or such greater number as would result in the\n supply of not less than 1.42 cubic metres of fresh air per minute\n for each bed in the room.\n--\nK\nDry provision store rooms\nNot less than 10 and not more than 20\n--\n(a) if at least two sides of the galley are exposed to the weather.\n(b) The Central Government may exempt any ship from these requirements to the extent that it is satisfied that compliance therewith is unnecessary by reason of the insulation of the equipment in the galley, or by reason of the size of the galley.\nThird Schedule\n[ See Schedule 1, Para 1(11)(a)]\nCertified for (*) seafarer(s)\nCertified for [Chief Officer]/[Master]/[Chief Engineer]/[**]\nCertified for (*) officers.\nCertified for (*) [ratings]/[petty officer].\nFourth Schedule\n[ See Schedule 1,para3(3)]\nElectric Lighting\n(A) Sleeping Room and Day Room:\n(1)\nAt general measurement points\n50 lux\n(2)\nAt every Mirror\n200 lux\n(3)\nAt every seat at a writing deck or table\n150 lux\n(4)\nAt not less than half the seats (other than those mentioned in\n (3) above) in a sleeping room provided for use of more than one\n person\n150 lux\n(B) Mess Room\n(1)\nAt general measurement points\n100 lux\n(2)\nAt every table and sink\n150 lux\n(C) Recreational Rooms (including for watching films and\n television hobbies, and games room):\n(1)\nAt general measurement points\n50 lux\n(2)\nAt every recreational table\n100 lux\n(3)\nAt every seat at a writing deck or table\n150 lux\n(4)\nAt not less than half the seats (other than those mentioned in\n (3) above)\n150 lux\n(D) Hospital\n(1)\nAt general measurement points\n50 lux\n(2)\nAt any wash room\n200 lux\n(3)\nAt least one fixed lamp shall be installed in addition to the\n electric reading lamp required by subpara (2) of para 3 to be\n provided at the head of each bed.\n150 lux\n(E) Offices and Studies\n(1)\nAt general measurement points\n100 lux\n(2)\nAt every seat at writing desk or table\n200 lux\n(F) Sanitary Accommodation (including sanitary accommodation\n in hospital):\n(1)\nAt general measurement points\n50 lux\n(2)\nAt every Mirror\n200 lux\n(G) Laundries\n(1)\nAt general measurement points\n100 lux\n(H) Drying Room:\n(1)\nAt the center of spaces\n50 lux\n(I) Galley (including bakeries and pantries):\n(1)\nAt working positions\nThe light shall be so disposed as to ensure that shelves and\n cupboards receive the maximum amount of light\n300 lux\n(J) Dry Provision Store Room and Cold Store Room:\n(1)\nAt general measurement points\nThe light shall be so disposed as to ensure that shelves and\n cupboards receive the maximum amount of light\n100 lux\n(K) Passage ways companionways and covered deck recreation\n spaces:\n(1)\nAt general measurement points\n50 lux\nA light shall be placed -\n(a) at the\n head of each stairway, ladder and hatchway, and\n(b) at or\n near the lockers provided for oilskins or working clothes.\nFifth Schedule\nCertificate of Seafarer Accommodation\n[See rule 6]\nCertificate of Seafarer Accommodation\nCertificate No.\nIssued under the provisions of the\nMerchant Shipping (Seafarer Accommodation) Rules, 2016.\nUnder the authority of the Government of India\nName of Ship\nDistinctive Number or Call Sign\nIMO Number\nPort of Registry\nGross Tonnage\nDate of Keel Laid*\nType of Ship\n:\n.................................\nArea of Operation\n:\nUnlimited / Restricted (see Remarks)\nMaster\n:\npersons\nOfficer\n:\npersons\nPetty Officers\n:\npersons\nRatings\n:\npersons\nTotal\n:\npersons",
        "footnote": "",
        "is_definition": false,
        "sort_order": 18
    },
    "prev_section": "11",
    "next_section": null
}