    "act_title": "Kerala Municipality Building Rules, 1999",
    "act_slug": "kerala-municipality-building-rules-1999",
    "section_label": "Section",
    "section": {
        "number": "45",
        "title": "45. Exit Width.",
        "chapter": null,
        "content": "Occupants per unit exit width\nOccupants per unit exit width\nSl. No.\nSl. No.\nGroup of occupancy\nGroup of occupancy\nNo. of Occupants per unit exit width of\n\t\t\t\tStairway\nNo. of Occupants per unit exit width of\n\t\t\t\tStairway\nDoors\nDoors\n(1)\n(1)\n(2)\n(2)\n(3)\n(3)\n(4)\n(4)\n1.\nGroup A1 Residential\n25\n75\n2.\nGroup A2 Special Residential\n50\n75\n3.\nGroup B Educational\n25\n75\n4.\nGroup C Medical/Hospital\n25\n75\n5.\nGroup D Assembly\n60\n90\n6.\nGroup E\n50\n75\n7.\nGroup F Mercantile (Commercial)\n50\n75\n8.\nGroup G1 Industrial\n50\n75\n9.\nGroup G2 Small Industrial\n50\n75\n10.\nGroup H Storage (including Warehousing)\n50\n75\n11.\nGroup I Hazardous\n25\n40\nOccupant Load\nOccupant Load\nSl. No.\nSl. No.\nGroup of occupancy\nGroup of occupancy\nOccupant Load (gross area in square meters per\n\t\t\t\tperson)\nOccupant Load (gross area in square meters per\n\t\t\t\tperson)\n(1)\n(1)\n(2)\n(2)\n(3)\n(3)\n1.\nGroup A1 Residential\n12.5\n2.\nGroup A2 Special Residential\n4.0\n3.\nGroup B Educational\n4.0\n4.\nGroup C Medical/Hospital\n15.0\n5.\nGroup D Assembly\n1.5\n6.\nGroup E Office\n1.5\n7.\nGroup F Mercantile (Commercial)\n3 to 6\n8.\nGroup G1 Industrial\n10.0\n9.\nGroup G2 Small Industrial\n10.0\n10.\nGroup H Storage (including Warehousing)\n30.0\n11.\nGroup I Hazardous\n10.0",
        "footnote": "",
        "is_definition": false,
        "sort_order": 45
    },
    "prev_section": "44",
    "next_section": "46"
}