    "act_title": "Kerala Municipality Building Rules, 1999",
    "act_slug": "kerala-municipality-building-rules-1999",
    "section_label": "Section",
    "section": {
        "number": "23",
        "title": "23. General requirement regarding plot.",
        "chapter": null,
        "content": "Clearance from Overhead Electric Lines\nClearance from Overhead Electric Lines\nSl.No\nSl.No\nType of Electric supply Line\nType of Electric supply Line\nMinimum Horizontal clearance in metres.\nMinimum Horizontal clearance in metres.\nMinimum Vertical clearance in metres.\nMinimum Vertical clearance in metres.\n1\nLow and medium voltage 2.40 1.20 lines\n2.40\n1.20\n2\nHigh voltage lines up to and including 33000\n\t\t\t\tvolts\n3.70\n1.85\n3\nExtra high voltage lines above 33000 volts\n3.70 plus 0.30m for every additional 33000 volts\n\t\t\t\tor part thereof\n1.85 plus 0.30m for every additional 33000 volts\n\t\t\t\tor part thereof",
        "footnote": "",
        "is_definition": false,
        "sort_order": 23
    },
    "prev_section": "22",
    "next_section": "24"
}