    "act_title": "Kerala Factories Rules, 1957",
    "act_slug": "kerala-factories-rules-1957",
    "section_label": "Section",
    "section": {
        "number": "81L",
        "title": "81L. Ovens and Driers.",
        "chapter": null,
        "content": "Application.\n(2) Definition.\n(3) Separate electrical connection.\n(4) Design, Construction, examination and testing.\n(b) No oven or drier shall be taken into use in a factory for the first time unless a Competent Person has thoroughly examined all its parts and carried out the tests as are required to establish that the necessary safe system and controls provided for safety in operation for the processes for which it is to be used and a certificate of such examination and tests signed by that Competent Person has been obtained and is kept available for inspection.\n(c) All parts of an oven or drier which has undergone any alteration or repair which has the effect of modifying any of the design characteristics shall not be used unless a thorough examination and tests as have been mentioned in clause (b) has been carried out by a Competent Person and a certificate of such examination and tests signed by that Competent Person has been obtained and is kept available for Inspection.\n(5) Safety ventilation.\n(b) The safe level of dilution referred to in clause (a) shall be so as to achieve a concentration of the concerned flammable substance in air of not more than 25 per cent of its lower explosive limit:\n(i) Shows continuously the concentration of the flammable substances in air present in the oven or drier at any instant;\n(ii) Sounds an alarm when the concentration of the flammable substance in air in any part of the oven or drier reaches a level of 30 percent of its lower explosive limit: and\n(iii) Shuts down the heating system of the oven or drier automatically when the concentration in air of the flammable substance in any part of the oven or drier reaches a level of 60 percent of its lower explosive limit, is provided to the oven or drier and maintained in efficient working condition.\n(c) No oven or drier shall be operated without its safety ventilation system working in an efficient manner\n(d) No oven or drier shall be operated with a level of dilution less than what is referred to in clause(b)\n(e) Exhaust ducts of safety ventilation systems should be so designed and placed that their ducts discharge the mixture of air and flammable substance away from the work-rooms and not near windows or doors and other opening from where the mixture could re-enter the work-rooms.\n(f) The fresh air admitted into the oven or drier by means of safety ventilation system shall be circulated adequately by means of circulating fan or fans through all parts of the oven or drier so as to ensure that there are no locations where the flammable substance can accumulate in the air or become packeted to any dangerous degree.\n(g) Throttling dampers in any safety ventilation system should be so designed by cutting away a portion of the damper or otherwise, that the system will handle at least the minimum ventilation rate required for safety when they are set in their maximum throttling position.\n(6) Explosion Panels.\n(b) The explosion releasing panels, shall, as far as practicable be situated at the roof of the oven or drier or at those portion of the wall where persons do not remain in connection with operation of the oven or drier.\n(7) Inter-locking arrangements.\n(i) all ventilating fans and circulating fans whose failure would adversely affected the ventilation rate of flow pattern, are in operation before any mechanical conveyor that may be provided for feeding the articles or substan ces to be processed in the oven or drier is put into operation;\n(ii) failure of any of the ventilating or circulating fans will automatically stop any conveyor as referred to in clause (i) as may be provided, as well as stop the fuel supply by closing the shut off valve and shut off the ignition in the case of gas or oil fired ovens, and in the case of electrically heated ovens switch off the electrical supply to the heaters.\n(iii) the above said mechanical conveyor is set in operation before the above said shut off valve can be energized; and\n(iv) the failure of the above said conveyor will automatically close the above said shut off valve in the case of ovens and driers heated by gas, oil or steam and de-activate the ignition system, or cut off the electrical heaters in the case of electrically heated, ovens or furnaces.\n(8) Automatic pre-ventilation.\n(9) Temperature control.\n(10) Multistage Processes.\n(11) Combustible substances not to drip on electrical heater or burners flame.\n(12) Periodic examination testing and maintenance.\n(b) A register shall be maintained in which the details of the various tests carried out from time to time under clause (a) shall be entered and every entry made shall be signed by the person making tests.\n(13) Training of Operators.\n(14) Polymerizing machines.\n(b)Infra-red ray heaters of polymerizing machines shall be out off while running the prints.]\n[81M. Thermic fluid heaters.\n(a) Level control in the expansion tank;\n(b) Temperature control of thermic fluid;\n(c) Differential pressure switch on the outlet line of the heater tubes and ;\n(d) Temperature control device for the fuel oil supply to the burner.\n(a) Weekly checks carried out confirming the effectiveness of the inter-lock.\n(b) Weekly checks confirming that all accessories are in good state of repairs; and\n(c) Information regarding fuel oil temperature, pressure thermic fluid inlet/outlet pressure and temperature, fuel gas temperature, recorded at 4 hourly intervals.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 157
    },
    "prev_section": "81K",
    "next_section": "81AA"
}