    "act_title": "Kerala Factories Rules, 1957",
    "act_slug": "kerala-factories-rules-1957",
    "section_label": "Section",
    "section": {
        "number": "17",
        "title": "17. Disposal of trade wastes and effluents.",
        "chapter": null,
        "content": "[17A. Limits of temperature and air movement.\nSchedule\nDry - bulb temperature\nDry - bulb temperature\nWet - bulb temperature\nWet - bulb temperature\n30 o C to 34 o C\n29 o C\n35 o C to 39 o C\n28.5 o C\n40 o C to 44 o C\n28 o C\n45 o C to 47 o C\n27.5 o C\nProvisions of thermometers.\n(b) If the inspector has reason to believe that a substantial amount of heat is added inside the environment of a workroom by radiation from walls, roof or other solid surroundings, he may serve on the manager on the factory an order requiring him to provide one or more globe thermometers referred to in the first proviso in sub rule (1) and further requiring him to place the globe thermometers at a place specified by him and keep a record of the temperature in a suitable register.\nVentilation.\n(i) covered by section 15; or\n(ii) in which temperature and humidity are controlled by refrigeration.\n(b) Where in any factory owing to special circumstances such a situation with respect to adjacent buildings and height of the building with respect to floor space, the requirements of ventilation opening under clause (a) of this sub-rule cannot be complied with or in the opinion of the Inspector the temperature of air in a workroom is sufficiently high and is likely to exceed the limits prescribed in sub-rule (1) he may serve on the manager of the factory an order requiring him to provide additional ventilation either by means of roof ventilation or by mechanical means.\n(c) The amount of fresh air supplied by mechanical means of ventilation in an hour shall be equivalent to at least six times the cubic capacity of the workroom and shall be distributed eventually throughout the workroom without dead air pockets or undue draughts caused by high inlet velocities.\n(d) In regions where in summer (15th March-15th July) dry-bulb temperatures of outside air in the shade during most part of the day exceed 35 degree centigrade and simultaneous wet-bulb temperatures are 25 degree centigrade or below and in the opinion of the Inspector the manufacturing process carried on in workroom of a factory permits thermal environments with relates humidity of 50% or more, the Inspector may serve on the manager of the factory an order to have sufficient supply of outside air for ventilation cooled by passing it through water sprays either by means of unit type of evaporative air coolers (Desert coolers) or, where supply of outside air is provided by mechanical means through ducts in a plenum system, by means of central air washing plants.]",
        "footnote": "",
        "is_definition": false,
        "sort_order": 19
    },
    "prev_section": "16",
    "next_section": "18"
}